LVAD Implant as a Bridge to Heart Transplantation Is Associated with Allosensitization as Measured by Single Antigen Bead Assay

被引:38
作者
Shankar, Nisha [1 ]
Daly, Richard [2 ]
Geske, Jennifer [2 ]
Kushwaha, Sudhir K. [2 ]
Timmons, Michael [2 ]
Joyce, Lyle [2 ]
Stulak, John [2 ]
Gandhi, Manish [2 ]
Kremers, Walter [2 ]
Park, Soon [2 ]
Pereira, Naveen L. [2 ]
机构
[1] Univ Connecticut, Ctr Hlth, Farmington, CT USA
[2] Mayo Clin, Rochester, MN 55905 USA
关键词
Heart transplant; HLA; Single antigen bead assay; Left ventricular assist device; CROSS-MATCH; ASSIST; SENSITIZATION; OUTCOMES; ANTIBODIES; RECIPIENTS; BLOOD;
D O I
10.1097/TP.0b013e3182985371
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Left ventricular assist devices (LVAD) as a bridge (BTT) to heart transplantation (HTX) may be limited by the formation of anti-human leukocyte antigen antibodies. Whether sensitization occurs with continuous axial flow LVAD implant as assessed by single antigen bead (SAB) assay is unknown. Methods. Cytotoxic panel-reactive antibody (PRA) and SAB assays were analyzed in HTX recipients undergoing LVAD implant as a BTT. Sensitization was defined as peak anti-human leukocyte antigen antibody values of more than 2000 mean fluorescence intensity because these values have been found to correlate with flow cytometric crossmatch results. Results. LVADs were implanted as BTT in 30 patients. There were 7% (2 of 30) of patients before LVAD implant and no patients after LVAD implant with PRA more than 10%. However, 20% (6 of 30) of patients before LVAD and 53% (16 of 30) after LVAD were sensitized as measured by SAB (P=0.024). At HTX, 47% (14 of 30) of patients remained sensitized. A positive virtual crossmatch was observed in 28% (4 of 14) of the sensitized patients at HTX. There was no difference between the sensitized and nonsensitized groups (P>0.4 for all) in usage of blood products (6411 vs. 6339 units) and time to HTX (28,663 vs. 25,748 days), and 1 year after HTX, there were no differences in rejection (total rejection score 0.30 vs. 0.37) and survival (93% vs. 88%). Conclusion. Allosensitization after LVAD is common despite cytotoxic PRA being negative. One year after HTX, this sensitization does not translate into increased acute cellular or antibody-mediated rejection or reduced survival.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 17 条
[1]   The clinical significance of flow cytometry crossmatching in heart transplantation - Conference discussion [J].
Hasse, J ;
Bishay, ES .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (04) :369-369
[2]   Lack of significant de novo HLA allosensitization in ventricular assist device recipients transfused with leukoreduced, ABO identical blood products [J].
Coppage, Myra ;
Baker, Marc ;
Fialkow, Lawrence ;
Meehan, Danielle ;
Gettings, Kelly ;
Chen, Leway ;
Massey, H. Todd ;
Blumberg, Neil .
HUMAN IMMUNOLOGY, 2009, 70 (06) :413-416
[3]   Prior Human Leukocyte Antigen-Allosensitization and Left Ventricular Assist Device Type Affect Degree of Post-implantation Human Leukocyte Antigen-Allosensitization [J].
Drakos, Stavros G. ;
Kfoury, Abdallah G. ;
Kotter, John R. ;
Reid, Bruce B. ;
Clayson, Stephen E. ;
Selzman, Craig H. ;
Stehlik, Josef ;
Fisher, Patrick W. ;
Merida, Mario, III ;
Eckels, David D. ;
Brunisholz, Kim ;
Horne, Benjamin D. ;
Stoker, Sandi ;
Li, Dean Y. ;
Renlund, Dale G. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (08) :838-842
[4]   Effect of Pretransplant Human Leukocyte Antigen Antibodies Detected by Solid-Phase Assay on Heart Transplant Outcomes [J].
Gandhi, M. J. ;
DeGoey, S. R. ;
Bundy, K. ;
Kremers, W. K. ;
Knauer, R. ;
Pereira, N. ;
Edwards, B. ;
Kushwaha, S. ;
Daly, R. C. .
TRANSPLANTATION PROCEEDINGS, 2011, 43 (10) :3840-3846
[5]   Association of device surface and biomaterials with immunologic sensitization after mechanical support [J].
George, Isaac ;
Colley, Patrick ;
Russo, Mark J. ;
Martens, Timothy P. ;
Burke, Elizabeth ;
Oz, Mehmet C. ;
Deng, Mario C. ;
Mancini, Donna M. ;
Naka, Yoshifumi .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (06) :1372-U310
[6]   Persistence of low levels of alloantibody after desensitization in crossmatch-positive living-donor kidney transplantation [J].
Gloor, JM ;
DeGoey, S ;
Ploeger, N ;
Gebel, H ;
Bray, R ;
Moore, SB ;
Dean, PG ;
Stegall, MD .
TRANSPLANTATION, 2004, 78 (02) :221-227
[7]   Impact of left venticular assist device (LVAD)-mediated humoral sensitization on post-transplant outcomes [J].
Joyce, DL ;
Southard, RE ;
Torre-Amione, G ;
Noon, GP ;
Land, GA ;
Loebe, M .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (12) :2054-2059
[8]  
Lo K, 2009, J HEART LUNG TRANSPL, V28, pS211, DOI 10.1016/j.healun.2008.12.017
[9]  
Malickaite Radvile, 2009, Interact Cardiovasc Thorac Surg, V8, P339, DOI 10.1510/icvts.2008.192567
[10]   Does successful bridging with the implantable left ventricular assist device affect cardiac transplantation outcome? [J].
Massad, MG ;
McCarthy, PM ;
Smedira, NG ;
Cook, DJ ;
Ratliff, NB ;
Goormastic, M ;
Vargo, RL ;
Navia, J ;
Young, JB ;
Stewart, RW .