Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve-in-valve deployment

被引:3
|
作者
Karahalios, Brian [1 ]
Breinholt, John P. [2 ]
Little, Stephen H. [3 ]
Huie Lin, C. [3 ]
机构
[1] Houston Methodist Hosp, Houston, TX 77030 USA
[2] Childrens Mem Hermann Hosp, Houston, TX USA
[3] Houston Methodist Debakey Heart & Vasc Ctr, Houston, TX USA
关键词
congenital heart disease; patient prosthesis mismatch; transcatheter valve replacement; REGURGITATION; SURGERY;
D O I
10.1002/ccd.28837
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
While transcatheter valve-in-valve (ViV) implantation may reduce the number of lifetime surgical reinterventions in some patients with congenital heart disease, in other patients the bioprosthetic valve ring can lead to patient-prosthesis mismatch due to reduction of internal diameter if a transcatheter valve is implanted. A 49-year-old woman with multiple prior cardiac surgeries presented with heart failure due to bioprosthetic tricuspid valve stenosis. Initial predilation valvuloplasty suggested conventional ViV implant would produce patient-prosthesis mismatch, therefore, we intentionally fractured the bioprosthetic valve ring to facilitate optimal hemodynamics with implantation of a 29 mm transcatheter valve.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [1] Bioprosthetic Valve Fracture to Facilitate Valve-in-Valve Transcatheter Aortic Valve Replacement
    Sreedharan, Subhashaan
    Sellers, Stephanie L.
    Ihdayhid, Abdul Rahman
    Landes, Uri
    Blanke, Philipp
    Allen, Keith B.
    Chhatriwalla, Adnan K.
    Pibarot, Philippe
    Wood, David A.
    Webb, John G.
    Leipsic, Jonathon A.
    Sathananthan, Janarthanan
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (01): : 24 - 38
  • [2] Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement
    Shahanavaz, Shabana
    Asnes, Jeremy D.
    Grohmann, Jochen
    Qureshi, Athar M.
    Rome, Jonathan J.
    Tanase, Daniel
    Crystal, Matthew A.
    Latson, Larry A.
    Morray, Brian H.
    Hellenbrand, William
    Balzer, David T.
    Gewillig, Marc
    Love, Jon C.
    Berdjis, Farhouch
    Gillespie, Matthew J.
    McElhinney, Doff B.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08)
  • [3] Transcatheter Tricuspid Valve-in-Valve Intervention for Degenerative Bioprosthetic Tricuspid Valve Disease
    Praz, Fabien
    George, Isaac
    Kodali, Susheel
    Koulogiannis, Konstantinos P.
    Gillam, Linda D.
    Bechis, Mary Z.
    Rubenson, David
    Li, Wei
    Duncan, Alison
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (04) : 491 - 504
  • [4] 1-Year Outcomes following Bioprosthetic Valve Fracture to Facilitate Valve-in-Valve Transcatheter Aortic Valve Replacement
    Chhatriwalla, Adnan K.
    Allen, Keith B.
    Saxon, John T.
    Cohen, David J.
    Nguyen, Tom C.
    Loyalka, Pranav
    Whisenant, Brian
    Yakubov, Steven J.
    Sanchez, Carlos
    Sathananthan, Janarthanan
    Stegman, Brian
    Harvey, James
    Garrett, H. Edward
    Tseng, Elaine
    Gerdisch, Marc
    Williams, Paul
    Kennedy, Kevin F.
    Webb, John
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (03): : 312 - 318
  • [5] Transcatheter valve-in-valve implantation in the tricuspid position
    Tzifa, Aphrodite
    Momenah, Tarek
    Al Sahari, Atif
    Al Khalaf, Khalaf
    Papagiannis, John
    Qureshi, Shakeel A.
    EUROINTERVENTION, 2014, 10 (08) : 995 - 999
  • [6] Transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic and mitral valves
    Gallo, Michele
    Dvir, Danny
    Demertzis, Stefanos
    Pedrazzini, Giovanni
    Berdajs, Denis
    Ferrari, Enrico
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (08) : 749 - 758
  • [7] Transcatheter aortic valve in valve implantation with bioprosthetic valve fracture
    James, Taylor M.
    Stamou, Sotiris C.
    Rothenberg, Mark
    Nores, Marcos A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (06) : 1170 - 1172
  • [8] Transcatheter Tricuspid Valve-in-Valve Replacement by Transatrial Approach
    Tinica, Grigore
    Nedelciuc, Igor
    Rotaru, Iulian
    Corciova, Flavia Catalina
    Grajdianu, Dumitru
    Tarus, Andrei
    Enache, Mihail
    Chistol, Raluca Ozana
    Cobzeanu, Maria Luiza
    Furnica, Cristina
    APPLIED SCIENCES-BASEL, 2020, 10 (18):
  • [9] Bioprosthetic Valve Remodeling of Trifecta Surgical Valves to Facilitate Valve-in-Valve TAVR
    Saxon, John T.
    Allen, Keith B.
    Cohen, David J.
    Hart, Anthony
    Dvir, Danny
    Chhatriwalla, Adnan K.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (02): : 99 - 104
  • [10] Efficacy and safety of transcatheter valve-in-valve replacement for Mitroflow bioprosthetic valve dysfunction
    Mosquera, Victor X.
    Gonzalez-Barbeito, Miguel
    Bouzas-Mosquera, Alberto
    Herrera-Norena, Jose M.
    Velasco, Carlos
    Salgado-Fernandez, Jorge
    Calvino-Santos, Ramon
    Vazquez-Gonzalez, Nicolas
    Vazquez-Rodriguez, Jose M.
    Cuenca-Castillo, Jose J.
    JOURNAL OF CARDIAC SURGERY, 2018, 33 (07) : 356 - 362