Trace analysis of bromate and bromide with ion chromatography on coated reversed phase materials

被引:15
|
作者
Bohme, U
Schmidt, W
Dietrich, PG
Matschi, A
Sacher, F
Brauch, HJ
机构
[1] DVGW TECHNOL ZENTRUM WASSER,AUSSENSTELLE DRESDEN,D-01139 DRESDEN,GERMANY
[2] AUF GMBH,D-1284 BERLIN,GERMANY
[3] DVGW TECHNOL ZENTRUM WASSER,D-76139 KARLSRUHE,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 06期
关键词
D O I
10.1007/s002160050225
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ion-chromatographic method for trace analysis of bromate and bromide presented in this paper is based on coating of reversed phase (RP) material with an ionogenic agent, tetrakisdecylammonium bromide, to obtain a pseudo ion-exchange column. The analysis is carried out with usual HPLC pump and UV-detection near 200 nm. Some commercially available RP materials were tested for the coating procedure. The differences between the reversed phases are not significant. All HETP values are calculated between 0.02 and 0.14 mm. The calibration, the sensitivity of the method and the long-time stability of the coated column were tested with one selected RP material. It is shown that the simultaneous trace analysis of bromate and bromide in surface and drinking waters with chloride concentrations up to 50 mg/L is possible without any clean-up on Ag precolumns. A comparison of performance data with a determination method for bromate and bromide employing a commercially available equipment demonstrates the efficiency of the new technique.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 50 条
  • [1] Trace analysis of bromate and bromide with ion chromatography on coated reversed phase materials
    U. Böhme
    W. Schmidt
    P. G. Dietrich
    A. Matschi
    F. Sacher
    H.-J. Brauch
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 629 - 634
  • [2] Ion chromatography on reversed-phase materials coated with mixed cationic and nonionic surfactants
    Yan, Z
    Haddad, PR
    Fritz, JS
    JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) : 359 - 365
  • [3] BROMATE ION ANALYSIS BY ION CHROMATOGRAPHY
    KOUDJONOU, BK
    MULLER, MC
    COSTENTIN, E
    RACAUD, P
    VANDERJAGT, H
    VILARO, JS
    HUTCHISON, J
    OZONE-SCIENCE & ENGINEERING, 1995, 17 (05) : 561 - 573
  • [4] Simultaneous analysis of iodate, iodide, bromate and bromide by ion chromatography with ultraviolet detection
    Li Meng
    Yu Hong
    Zheng Xiurong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (03) : 299 - 303
  • [5] Determination of trace concentrations of bromate and bromide in natural mineral waters by reagent-free ion chromatography
    De Borba, Brian
    Rohrer, Jeffrey S.
    LC GC NORTH AMERICA, 2007, : 22 - 22
  • [6] Determination of trace concentrations of bromate and bromide in natural mineral waters by reagent-free ion chromatography
    De Borba, Brian
    Rohrer, Jeffrey S.
    LC GC EUROPE, 2007, : 18 - 18
  • [7] Determination of Trace Bromate in Drinking Water with Ion Chromatography
    Chen Rui
    Fu Xue-qi
    Shi Ying-lin
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [8] STUDIES ON REVERSED PHASE ION-PAIR CHROMATOGRAPHY WITH A DYNAMICALLY COATED ADSORBENT
    JOHANSSON, M
    ACTA PHARMACEUTICA SUECICA, 1981, 18 (04): : 254 - 254
  • [9] Determination of trace amounts of bromate ion by ion chromatography with a graphitized carbon column
    Isozaki, A
    Shimamura, H
    Takeda, S
    Nagashima, H
    Okutani, T
    BUNSEKI KAGAKU, 1999, 48 (10) : 891 - 896
  • [10] CATION CHROMATOGRAPHY ON COATED REVERSED PHASE COLUMNS
    SCHMIDT, W
    FUCHTNER, F
    ZEITSCHRIFT FUR CHEMIE, 1988, 28 (12): : 453 - 454