Ion concentration polarization for pre-concentration of biological samples without pH change

被引:17
作者
Cho, Youngkyu [1 ]
Yoon, Junghyo [2 ]
Lim, David Wonbin [2 ]
Kim, Jaehoon [2 ]
Lee, Jeong Hoon [3 ]
Chung, Seok [1 ,2 ]
机构
[1] Korea Univ, Dept IT Convergence, 145 Anam Ro, Seoul 02841, South Korea
[2] Korea Univ, Sch Mech Engn, 145 Anam Ro, Seoul 02841, South Korea
[3] Kwangwoon Univ, Dept Elect Engn, 20 Gwangun Ro, Seoul 01897, South Korea
基金
新加坡国家研究基金会;
关键词
D O I
10.1039/c6an02152b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a method was developed for pre-concentrating large-volume biological samples for subsequent analysis. We previously developed another pre-concentration device, but it unfortunately altered the pH of the sample when an electric field was applied to the sample reservoir. Changes in the pH are not suitable for subsequent antibody-antigen reactions because of the stability issues that arise based on the target molecule's isoelectric point (pI). Here, this problem was overcome using ion concentration polarization (ICP) with a cation selective membrane (Nafion). Phosphate buffered saline was used as a test solution for the sample. The sample was contained in a reservoir that was not affected by the electric field, and an ICP barrier was formed in front of the reservoir. This device could concentrate microliter-scale samples without changing the pH because the biomolecules were blocked from passing through the ICP barrier while the sample (phosphate buffered saline) was drained. A 40 mu L sample was successfully pre-concentrated to 20 mu L in a single channel device and 10 mu L in a dual channel device, resulting in 2.1-fold and 3.3-fold increases, respectively, in influenza hemagglutinin concentrations. These changes in the concentration were confirmed by ELISA.
引用
收藏
页码:6510 / 6514
页数:5
相关论文
共 17 条
[11]   Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membrane [J].
Lee, Jeong Hoon ;
Song, Yong-Ak ;
Han, Jongyoon .
LAB ON A CHIP, 2008, 8 (04) :596-601
[12]  
Reverberi Roberto, 2007, Blood Transfus, V5, P227, DOI 10.2450/2007.0047-07
[13]   On the pH-optimum of activity and stability of proteins [J].
Talley, Kemper ;
Alexov, Emil .
PROTEINS-STRUCTURE FUNCTION AND BIOINFORMATICS, 2010, 78 (12) :2699-2706
[14]   Pre-binding dynamic range and sensitivity enhancement for immuno-sensors using nanofluidic preconcentrator [J].
Wang, Ying-Chih ;
Han, Jongyoon .
LAB ON A CHIP, 2008, 8 (03) :392-394
[15]   Tunable sheathless microfluidic focusing using ion concentration polarization [J].
Yoon, Junghyo ;
Cho, Youngkyu ;
Lee, Jeong Hoon ;
Chung, Seok .
APPLIED PHYSICS LETTERS, 2015, 107 (08)
[16]   Microfluidic in-reservoir pre-concentration using a buffer drain technique [J].
Yoon, Junghyo ;
Cho, Youngkyu ;
Han, Sewoon ;
Lim, Chae Seung ;
Lee, Jeong Hoon ;
Chung, Seok .
LAB ON A CHIP, 2014, 14 (15) :2778-2782
[17]   Selection of Nonequilibrium Overlimiting Currents: Universal Depletion Layer Formation Dynamics and Vortex Instability [J].
Yossifon, Gilad ;
Chang, Hsueh-Chia .
PHYSICAL REVIEW LETTERS, 2008, 101 (25)