Influence of voxel size on the diagnostic ability of cone-beam computed tomography to evaluate simulated root perforations

被引:8
作者
Venskutonis, Tadas [1 ]
Juodzbalys, Gintaras [2 ]
Nackaerts, Olivia [3 ]
Mickeviciene, Lina [1 ]
机构
[1] Lithuanian Univ Hlth Sci, Dept Dent & Oral Dis, LT-50009 Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Dept Maxillofacial Surg, LT-50009 Kaunas, Lithuania
[3] Katholieke Univ Leuven, Oral Imaging Ctr, B-3000 Louvain, Belgium
关键词
X-ray diagnosis; Endodontics; Root canal therapy; Cone-beam computed tomography; Dental radiography; INTRAORAL RADIOGRAPHY; ENDODONTIC FAILURES; IMAGE QUALITY; CT; RESORPTION; RESOLUTION; DOSIMETRY; DEVICES;
D O I
10.1007/s11282-013-0125-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to assess the use of different voxel sizes of a cone-beam computed tomography (CBCT) unit for detecting root perforations of different sizes and locations ex vivo and to compare the diagnostic possibilities of CBCT with those of periapical radiography (PR). The study included 36 recently extracted intact human mandibular one-rooted teeth with developed apices. Root perforations of 0.2, 0.3, or 0.4 mm in diameter were drilled on the buccal and lingual sides at the cervical, middle, and apical thirds. A total of 216 portions were obtained. One tooth at a time was placed in a dry human mandible in an artificially created alveolus. Cross-sectional CBCT images were obtained using voxel resolutions of 0.4, 0.3, 0.25, and 0.2 mm. PRs were obtained using the paralleling technique in three directions in the horizontal plane: direct view, mesial angulation, and distal angulation with a 20A degrees angle. There were no significant differences in sensitivity between 0.4/0.3 and 0.25/0.2-mm voxel resolutions. Significant differences were found between voxel sizes of 0.4/0.25, 0.4/0.2, 0.3/0.25, and 0.3/0.2 mm. The observers failed to diagnose any of the perforations using PR. CBCT is a reliable imaging system for detecting root perforations that are not detectable with PR. A 0.2-mm voxel resolution was the best choice for diagnostic use in this study. Neither perforation location nor size influenced the diagnostic abilities of CBCT, except that it was harder to detect a root perforation in the apical part of the root.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 50 条
[21]   Optimizing voxel-wise dose calculations in cone-beam computed tomography [J].
Kim, Jinwoo ;
Yun, Jonghee ;
Ha, Seungwoo ;
Youn, Hanbean ;
Jeon, Hosang ;
Kim, Ho Kyung .
MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
[22]   Evaluation of Cone-beam Computed Tomography in the Diagnosis of Vertical Root Fractures: The Influence of Imaging Modes and Root Canal Materials [J].
Neves, Frederico Sampaio ;
Freitas, Deborah Queiroz ;
Flores Campos, Paulo Sergio ;
Ekestubbe, Annika ;
Lofthag-Hansen, Sara .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1530-1536
[23]   An Ex Vivo Comparison of Diagnostic Accuracy of Cone-beam Computed Tomography and Periapical Radiography in the Detection of Furcal Perforations [J].
Kamburoglu, Kivanc ;
Yeta, Elif Naz ;
Yilmaz, Funda .
JOURNAL OF ENDODONTICS, 2015, 41 (05) :696-702
[24]   Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations [J].
Shokri, Abbas ;
Eskandarloo, Amir ;
Norouzi, Marouf ;
Poorolajal, Jalal ;
Majidi, Gelareh ;
Aliyaly, Alireza .
IMAGING SCIENCE IN DENTISTRY, 2018, 48 (01) :11-19
[25]   Influence of Tube Current Settings on Diagnostic Detection of Root Fractures Using Cone-beam Computed Tomography: An In Vitro Study [J].
Tangari-Meira, Ricardo ;
Vancetto, Jose Ricardo ;
Dovigo, Livia Nordi ;
Tosoni, Guilherme Monteiro .
JOURNAL OF ENDODONTICS, 2017, 43 (10) :1701-1705
[26]   Use of cone-beam computed tomography to evaluate root and canal morphology of mandibular molars in Chinese individuals [J].
Zhang, R. ;
Wang, H. ;
Tian, Y. -Y. ;
Yu, X. ;
Hu, T. ;
Dummer, P. M. H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (11) :990-999
[27]   In Vitro Comparison of the Accuracy of Cone-Beam Computed Tomography Scanning and Electronic Apex Locators in Detection of Simulated Root Perforations in Different Localizations [J].
Harorli, Hatice ;
Koc, Simay ;
Kustarci, Alper .
JOURNAL OF ENDODONTICS, 2023, 49 (12) :1676-1681
[28]   Cone-beam computed tomography for trauma [J].
Gupta, Saurabh ;
Martinson, James R. ;
Ricaurte, Daniel ;
Scalea, Thomas M. ;
Morrison, Jonathan J. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03) :E34-E40
[29]   Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study [J].
Dalili, Zahra ;
Taramsari, Mehran ;
Mehr, Seyed Zoheir Mousavi ;
Salamat, Fatemeh .
IMAGING SCIENCE IN DENTISTRY, 2012, 42 (01) :19-24
[30]   Cone-beam computed tomography-based descriptive classification for transverse root fracture [J].
Saini, Aakriti ;
Sharma, Sidhartha ;
Kumar, Vijay ;
Chawla, Amrita ;
Gupta, Shalini ;
Kahler, Bill ;
Logani, Ajay .
AUSTRALIAN ENDODONTIC JOURNAL, 2024, 50 (03) :718-728