Biomechanical Evaluation of the X-Stop Device for Surgical Treatment of Lumbar Spinal Stenosis

被引:10
作者
Wan, Zongmiao [2 ,3 ]
Wang, Shaobai [2 ,4 ]
Kozanek, Michal [2 ,5 ]
Passias, Peter G. [2 ]
Mansfield, Frederick L. [2 ]
Wood, Kirkham B. [2 ]
Li, Guoan [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Bioengn Lab,Dept Orthopaed, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Cent S Univ, Xiangya Hosp 2, Changsha, Hunan, Peoples R China
[4] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[5] Comenius Univ, Fac Med, Fac Hosp Ruzinov, Dept Orthopaed & Traumatol 1, Bratislava, Slovakia
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2012年 / 25卷 / 07期
关键词
in vivo; spinous process; kinematics; X-Stop; lumbar spine stenosis; NEUROGENIC INTERMITTENT CLAUDICATION; INTERSPINAL PROCESS DECOMPRESSION; PROCESS IMPLANT; KINEMATICS; SPONDYLOLISTHESIS; MULTICENTER; EXTENSION; INSERTION;
D O I
10.1097/BSD.0b013e318227eb84
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Controlled experimental study. Objective: To evaluate the kinematical effects of X-Stop device on the spinal process at the operated and the adjacent segments before and after X-Stop surgeries during various weight-bearing postures in elderly patients with lumbar spine stenosis. Summary of Background Data: The mechanism of interspinous process (ISP) devices is to directly distract the ISP of the implanted level to indirectly decompress the intervertebra foramen and spinal canal. Few studies have investigated the changes of ISP gap caused by X-Stop implantation using magnetic resonance imaging or radiography, but the effect of X-Stop surgery on the kinematics of spinous processes during functional activities is still unclear. Methods: Eight patients were tested before and, on average, 7 months after surgical implantation of the X-Stop devices using a combined computed tomography/magnetic resonance imaging and dual fluoroscopic imaging system during weight-bearing standing, flexion-extension, left-right bending, and left-right twisting positions of the torso. The shortest distances of the ISPs at the operated and the adjacent levels were measured using iterative closest point method and was dissected into vertical (gap) and horizontal (lateral translation) components. Results: At the operated levels, the shortest vertical ISP distances (gap) significantly (P < 0.05) increased by 1.5 mm during standing, 1.2 mm during left twist, 1.3 mm during extension, and 1.1 mm during flexion, whereas they also increased yet not significantly (P > 0.05) in right twist, left bend, and right bend after the X-Stop implantation. The lateral translations were not significantly affected. At both cephalad and caudad adjacent levels, the ISP distances (vertical and horizontal) were not significantly affected during all postures after X-Stop implantation. Conclusion: The findings of this study indicate that implantation of the X-Stop devices can effectively distract the ISP space at the diseased level without causing apparent kinematic changes at the adjacent segments during the studied postures.
引用
收藏
页码:374 / 378
页数:5
相关论文
共 23 条
[1]   Treatment of neurogenic claudication by interspinous decompression: application of the X STOP device in patients with lumbar degenerative spondylolisthesis [J].
Anderson, Paul A. ;
Tribus, Cliff B. ;
Kitchel, Scott H. .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (06) :463-471
[2]   Interspinous process devices in the lumbar spine [J].
Bono, Christopher M. ;
Vaccaro, Alexander R. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (03) :255-261
[3]   Dynamic interspinous process stabilization: review of complications associated with the X-Stop device [J].
Bowers, Christian ;
Amini, Amin ;
Dailey, Andrew T. ;
Schmidt, Meic H. .
NEUROSURGICAL FOCUS, 2010, 28 (06) :1-6
[4]   Back pain, neurogenic symptoms, and physical function in relation to spondylolisthesis among elderly men [J].
Denard, Patrick J. ;
Holton, Kathleen F. ;
Miller, Jessica ;
Fink, Howard A. ;
Kado, Deborah M. ;
Marshall, Lynn M. ;
Yoo, Jung U. .
SPINE JOURNAL, 2010, 10 (10) :865-873
[5]   A novel technique of intra-spinous process injection of PMMA to augment the strength of an inter-spinous process device such as the X STOP [J].
Idler, Cary ;
Zucherman, James F. ;
Yerby, Scott ;
Hsu, Ken Y. ;
Hannibal, Matthew ;
Kondrashov, Dimitriy .
SPINE, 2008, 33 (04) :452-456
[6]   Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement [J].
Inufusa, A ;
An, HS ;
Lim, TH ;
Hasegawa, T ;
Haughton, VM ;
Nowicki, BH .
SPINE, 1996, 21 (21) :2412-2420
[7]   Interspinous process decompression with the X-STOP device for lumbar spinal stenosis - A 4-year follow-up study [J].
Kondrashov, Dimitriy G. ;
Hannibal, Matthew ;
Hsu, Ken Y. ;
Zucherman, James F. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (05) :323-327
[8]   An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients - Preliminary experiences in 10 consecutive coses [J].
Lee, JB ;
Hida, K ;
Seki, T ;
Iwasaki, Y ;
Minoru, A .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (01) :72-77
[9]   In vivo articular cartilage contact kinematics of the knee - An investigation using dual-orthogonal fluoroscopy and magnetic resonance image-based computer models [J].
Li, GA ;
DeFrate, LE ;
Park, SE ;
Gill, TJ ;
Rubash, HE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (01) :102-107
[10]   Segmental in vivo vertebral motion during functional human lumbar spine activities [J].
Li, Guoan ;
Wang, Shaobai ;
Passias, Peter ;
Xia, Qun ;
Li, Gang ;
Wood, Kirkham .
EUROPEAN SPINE JOURNAL, 2009, 18 (07) :1013-1021