Detection of high-intensity focused ultrasound liver lesions using dynamic elastometry

被引:43
作者
Shi, XG
Martin, RW
Rouseff, D
Vaezy, S
Crum, LA
机构
[1] Univ Washington, Bioengn Lab, Seattle, WA 98195 USA
[2] Univ Washington, Anesthesiol Lab, Seattle, WA 98195 USA
[3] Univ Washington, Appl Phys Lab, Seattle, WA 98195 USA
关键词
Doppler; dynamic elastometry; HIFU; lesion detection; liver; stiffness; strain; stress; ultrasound; vibration; Young's modulus;
D O I
10.1177/016173469902100203
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A novel ultrasound technique was developed for detecting the distribution of stiffness in biological tissue. The method, which we call 'dynamic elastometry,' involves applying a low-frequency vibration (less than or equal to 5 Hz) to the tissue and measuring the resulting velocity pattern within the sample using Doppler spectral analysis. Based upon the velocity differences, an elastically stiff region can be differentiated from surrounding soft tissue. Dynamic elastometry was used to both detect and quantify lesions produced by high-intensity focused ultrasound (HIFU) in porcine livers. Measurements of the lesion position and length agreed well with independent geometric measurements. The mean and standard deviation of the differences between the two types of measurement were -0.01 cm and 0.10 cm for lesion position, and -0.05 cm and 0.12 cm for lesion length, respectively. The relative stiffness between lesions and normal liver tissue was estimated by the velocity gradient ratio. Results were compared with the Young's modulus ratios between lesion and normal liver tissue obtained from mechanical measurement. The dynamic elastometric estimates had a strong linear correlation with the mechanical measurements (r = 0.93) but were smaller than the latter by 26%.
引用
收藏
页码:107 / 126
页数:20
相关论文
共 39 条
  • [31] TERHAAR G, 1989, PHYS MED BIOL, V34, P1743, DOI 10.1088/0031-9155/34/11/021
  • [32] ULTRASOUND FOCAL BEAM SURGERY
    TERHAAR, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) : 1089 - 1100
  • [33] Liver hemostasis using high-intensity focused ultrasound
    Vaezy, S
    Martin, R
    Schmiedl, U
    Caps, M
    Taylor, S
    Beach, K
    Carter, S
    Kaczkowski, P
    Keilman, G
    Helton, S
    Chandler, W
    Mourad, P
    Rice, M
    Roy, R
    Crum, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (09) : 1413 - 1420
  • [34] Hemostasis of punctured blood vessels using high-intensity focused ultrasound
    Vaezy, S
    Martin, R
    Yaziji, H
    Kaczkowski, P
    Keilman, G
    Carter, S
    Caps, M
    Chi, EY
    Bailey, M
    Crum, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) : 903 - 910
  • [35] VANBAREN P, 1996 IEEE ULTR S P, P1269
  • [36] ULTRASONIC-IMAGING OF INTERNAL VIBRATION OF SOFT-TISSUE UNDER FORCED VIBRATION
    YAMAKOSHI, Y
    SATO, J
    SATO, T
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (02) : 45 - 53
  • [37] YAMASHITA Y, 1994 ULTR S P, P1449
  • [38] YANG R, 1993, INVEST RADIOL, V28, P796
  • [39] ZHONG X, 1997 IEEE ULTR S P, P1381