Patient ocular conditions and clinical outcomes using a PROSE scleral device

被引:60
作者
Dimit, Ryan [1 ]
Gire, Anisa [1 ,2 ]
Pflugfelder, Stephen C. [1 ]
Bergmanson, Jan P. G. [3 ]
机构
[1] Baylor Coll Med, Alkek Eye Ctr, Houston, TX 77030 USA
[2] Johns Hopkins Univ, Wilmer Eye Inst, Baltimore, MD 21218 USA
[3] Univ Houston, Coll Optometry, Texas Eye Res & Technol Ctr, Houston, TX USA
关键词
Scleral contact lenses; Keratoconus; Dry eye; Visual function; Questionnaire; CONTACT-LENS; MICROBIAL KERATITIS; SURFACE DISEASE;
D O I
10.1016/j.clae.2013.02.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the type and distribution of ocular conditions cared for in a clinic dedicated to scleral devices and to report the clinical outcomes afforded by this approach. Methods: Fifty-one charts of patients fitted unilaterally or bilaterally with a scleral device (Prosthetic Replacement of the Ocular Surface Ecosystem - PROSE) in a two year period were retrospectively reviewed. Patient demographics, ocular diagnoses, associated systemic conditions, best corrected visual acuity (BCVA) before and after fitting, Visual Function Questionnaire score (VFQ-25), and ocular surface disease index (OSDI) score were collected. Results: All 51 patients were successfully wearing the PROSE device for a period of anywhere from weeks to years. The most common reasons for fitting were to relieve symptoms of moderate to severe dry eye syndrome ("DES", n = 25), management of refractive problems ("refractive", n = 23) with keratoconus being the most common (n = 14), and to manage other anomalies ("other", n = 3). Best corrected visual acuity (logMAR) improved with the wearing of the PROSE device for both the DES (17 letters) and the refractive group (10 letters), but not the "other" group. No serious complications were recorded for any of the patients. Conclusions: The PROSE device is a useful option not only for the management of ocular surface disease and optical imperfections, but also for other ophthalmic conditions. Moderate to severe dry eye was the most common anomaly managed, followed by eyes with irregular corneal astigmatism. DES and refractive patients experienced improvement in visual acuity with wearing of the PROSE device. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 28 条
[1]  
[Anonymous], 2007, OCULAR SURFACE, V5, P93
[2]  
BIER N, 1947, Am J Optom Arch Am Acad Optom, V24, P611
[3]  
Bowden TJ, 2009, CONTACT LENSES STORY, P40
[4]   Incidence of contact-lens-associated microbial keratitis and its related morbidity [J].
Cheng, KH ;
Leung, SL ;
Hoekman, HW ;
Beekhuis, WH ;
Mulder, PGH ;
Geerards, AJM ;
Kijlstra, A .
LANCET, 1999, 354 (9174) :181-185
[5]  
Ezekiel D., 1983, J BR CONT LENS ASS, V6, P158, DOI DOI 10.1016/S0141-7037(83)80064-0
[6]  
Feinbloom W., 1937, Am. J. Optom, V14, P41
[7]  
Fick AE., 1888, Arch Ophthalmol, V17, P215
[8]  
Fritz A, 1939, B SOC OPHTHAL BELGE, V78, P71
[9]   Update on scleral lenses [J].
Jacobs, Deborah S. .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) :298-301
[10]   Development of the 25-item National Eye Institute Visual Function Questionnaire [J].
Mangione, CM ;
Lee, PP ;
Gutierrez, PR ;
Spritzer, K ;
Berry, S ;
Hays, RD .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (07) :1050-1058