Clinical evaluation of analytical variations in serum creatinine measurements: why laboratories should abandon Jaffe techniques

被引:75
作者
Drion, Iefke [1 ]
Cobbaert, Christa [2 ]
Groenier, Klaas H. [1 ,3 ]
Weykamp, Cas [4 ]
Bilo, Henk J. G. [1 ,5 ,6 ]
Wetzels, Jack F. M. [7 ]
Kleefstra, Nanne [1 ,5 ,8 ]
机构
[1] Isala Clin, Ctr Diabet, NL-8000 GK Zwolle, Netherlands
[2] Leiden Univ, Med Ctr, Dept Clin Chem & Lab Med, Leiden, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Gen Practice, NL-9713 AV Groningen, Netherlands
[4] Streekziekenhuis Koningin Beatrix, European Reference Lab, Winterswijk, Netherlands
[5] Univ Med Ctr Groningen, Dept Internal Med, NL-9713 AV Groningen, Netherlands
[6] Isala Clin, Dept Internal Med, NL-8000 GK Zwolle, Netherlands
[7] Radboud Univ Nijmegen, Med Ctr, Dept Nephrol, NL-6525 ED Nijmegen, Netherlands
[8] Langerhans Med Res Grp, Zwolle, Netherlands
关键词
Calibration; Glomerular filtration rate; Isotope dilution-mass spectrometry; Renal function; Reference standards; Traceability; GLOMERULAR-FILTRATION-RATE; EXTERNAL QUALITY ASSESSMENT; CANDIDATE REFERENCE METHODS; INTERNAL ACCURACY CONTROL; DETERMINING TARGET VALUES; RENAL-DISEASE; URIC-ACID; GC-MS; TIME; CALIBRATION;
D O I
10.1186/1471-2369-13-133
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Non-equivalence in serum creatinine (SCr) measurements across Dutch laboratories and the consequences hereof on chronic kidney disease (CKD) staging were examined. Methods: National data from the Dutch annual external quality organization of 2009 were used. 144 participating laboratories examined 11 pairs of commutable, value-assigned SCr specimens in the range 52-262 mu mol/L, using Jaffe or enzymatic techniques. Regression equations were created for each participating laboratory (by regressing values as measured by participating laboratories on the target values of the samples sent by the external quality organization); area under the curves were examined and used to rank laboratories. The 10th and 90th percentile regression equation were selected for each technique separately. To evaluate the impact of the variability in SCr measurements and its eventual clinical consequences in a real patient population, we used a cohort of 82424 patients aged 19-106 years. The SCr measurements of these 82424 patients were introduced in the 10th and 90th percentile regression equations. The newly calculated SCr values were used to calculate an estimated glomerular filtration rate (eGFR) using the 4-variable Isotope Dilution Mass Spectrometry traceable Modification of Diet in Renal Disease formula. Differences in CKD staging were examined, comparing the stratification outcomes for Jaffe and enzymatic SCr techniques. Results: Jaffe techniques overestimated SCr: 21%, 12%, 10% for SCr target values 52, 73 and 94 mu mol/L, respectively. For enzymatic assay these values were 0%, -1%, -2%, respectively. eGFR using the MDRD formula and SCr measured by Jaffe techniques, staged patients in a lower CKD category. Downgrading to a lower CKD stage occurred in 1-42%, 2-37% and 12-78.9% of patients for the 10th and 90th percentile laboratories respectively in CKD categories 45-60, 60-90 and >90 ml/min/1.73 m(2). Using enzymatic techniques, downgrading occurred only in 2-4% of patients. Conclusions: Enzymatic techniques lead to less variability in SCr measurements than Jaffe techniques, and therefore result in more accurate staging of CKD. Therefore the specific enzymatic techniques are preferably used in clinical practice in order to generate more reliable GFR estimates.
引用
收藏
页数:8
相关论文
共 34 条
[1]  
[Anonymous], CLIN CHEM LAB MED
[2]  
Carobene A, 1997, CLIN CHEM, V43, P1342
[3]   Prime Time for Enzymatic Creatinine Methods in Pediatrics [J].
Cobbaert, Christa M. ;
Baadenhuijsen, Henk ;
Weykamp, Cas W. .
CLINICAL CHEMISTRY, 2009, 55 (03) :549-558
[4]  
COOK J G H, 1975, Annals of Clinical Biochemistry, V12, P219
[5]   Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rate [J].
Coresh, J ;
Astor, BC ;
McQuillan, G ;
Kusek, J ;
Greene, T ;
Van Lente, F ;
Levey, AS .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (05) :920-929
[6]   Estimating the prevalence of low glomerular filtration rate requires attention to the creatinine assay calibration [J].
Coresh, J ;
Eknoyan, G ;
Levey, AS .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (11) :2811-2812
[7]   NEGATIVE INTERFERENCE IN A KINETIC JAFFE METHOD FOR SERUM CREATININE DETERMINATION [J].
CRUICKSHANK, AM ;
BALLANTYNE, FC ;
SHENKIN, A .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :112-113
[8]   The new European directive on in vitro diagnostics [J].
Dati, F .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (10) :1289-1298
[9]   Certification of creatinine in a human serum reference material by GC-MS and LC-MS [J].
Dodder, Nathan G. ;
Tai, Susan S. -C. ;
Sniegoski, Lorna T. ;
Zhang, Nien F. ;
Welch, Michael J. .
CLINICAL CHEMISTRY, 2007, 53 (09) :1694-1699
[10]  
Drion Iefke, 2011, Ned Tijdschr Geneeskd, V155, pA3091