Contrast-Enhanced Ultrasound in Cystic Endometrial Hyperplasia-Pyometra Complex in the Bitch: A Preliminary Study

被引:8
作者
Quartuccio, Marco [1 ]
Liotta, Luigi [1 ]
Cristarella, Santo [1 ]
Lanteri, Giovanni [1 ]
Ieni, Antonio [1 ]
D'Arrigo, Tiziana [1 ]
De Majo, Massimo [1 ]
机构
[1] Univ Messina, Dept Vet Sci, I-98168 Messina, Italy
来源
ANIMALS | 2020年 / 10卷 / 08期
关键词
dog; cystic endometrial hyperplasia; pyometra; contrast-enhanced ultrasonography; GROWTH-FACTOR; ULTRASONOGRAPHY; CANINE; PROLIFERATION; INFERTILITY; EXPRESSION; BIOPSIES;
D O I
10.3390/ani10081368
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary In canine cystic endometrial hyperplasia-pyometra (CEH) syndrome, toxic factors and endometrial inflammatory reactions are responsible of increased blood flow and lower vascular resistance in uterine arteries. Color Doppler ultrasound is regarded as an adjunctive tool for quantitative assessment of endometrial vascularization during uterine disorders. The aim of this study was to assess, through contrast-enhanced ultrasound (CEUS) exam, the vascularization in endometrial microvessels in CEH-pyometra in order to evaluate the possibility of application in this syndrome. In twelve female dogs with clinical symptoms related to pyometra, echographic, Color Doppler and CEUS exams were performed. Histopathological examination revealed severe CEH and pyometra, immunohistochemical stain with CD 34 confirmed the presence of angiogenesis. CEUS exam revealed a widespread, intense and rapidly developing homogeneous enhancement of the hyperplastic endometrium with absence of signal only in cystic areas. All parameters of the quantitative analysis were not significantly influenced by region of interest dimension and position. CEUS may improve not invasive evaluations in the CEH-pyometra syndrome and virtually in CEH-mucometra. In cystic endometrial hyperplasia (CEH)-pyometra syndrome, toxic factors and endometrial remodeling culminate in changes characterized by exudative and degenerative inflammatory reaction. Recent studies on hemodynamic found an increased blood flow and lower vascular resistance in uterine arteries, suggesting color Doppler ultrasound as an adjunctive tool for quantitative assessment of endometrial vascularization during pyometra. The aim of this study was to assess, through contrast-enhanced ultrasound (CEUS) exam, the vascularization in endometrial microvessels in CEH-pyometra in order to evaluate the possibility of application in this syndrome. In twelve female dogs with clinical symptoms related to pyometra, B-mode, color Doppler and CEUS exams were performed. In CEH-pyometra uteri, histopathological examination revealed severe CEH and pyometra, immunohistochemical stain with CD 34 confirmed the presence of angiogenesis. CEUS exams revealed a widespread, intense and rapidly developing homogeneous enhancement of the hyperplastic endometrium, with absence of signal only in cystic areas. All parameters of the quantitative analysis were not significantly influenced by region of interest dimension and position. CEUS has the potential to improve clinical not invasive evaluations in the CEH-pyometra syndrome and virtually in CEH-mucometra.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 47 条
  • [1] Uterine blood flow evaluation in bitches suffering from cystic endometrial hyperplasia (CEH) and CEH-pyometra complex
    Batista, P. R.
    Gobello, C.
    Rube, A.
    Corrada, Y. A.
    Tortora, M.
    Blanco, P. G.
    [J]. THERIOGENOLOGY, 2016, 85 (07) : 1258 - 1261
  • [2] Doppler ultrasonographic assessment of uterine arteries during normal canine puerperium
    Batista, P. R.
    Gobello, C.
    Corrada, Y.
    Pons, E.
    Arias, D. O.
    Blanco, P. G.
    [J]. ANIMAL REPRODUCTION SCIENCE, 2013, 141 (3-4) : 172 - 176
  • [3] INDUCTION OF VASCULAR ENDOTHELIAL GROWTH-FACTOR EXPRESSION IN SYNOVIAL FIBROBLASTS BY PROSTAGLANDIN-E AND INTERLEUKIN-1 - A POTENTIAL MECHANISM FOR INFLAMMATORY ANGIOGENESIS
    BENAV, P
    CROFFORD, LJ
    WILDER, RL
    HLA, T
    [J]. FEBS LETTERS, 1995, 372 (01) : 83 - 87
  • [4] Ultrasonography and cystic hyperplasia-pyometra complex in the bitch
    Bigliardi, E
    Parmigiani, E
    Cavirani, S
    Luppi, A
    Bonati, L
    Corradi, A
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2004, 39 (03) : 136 - 140
  • [5] Ultrasonographic assessment of maternal cardiac function and peripheral circulation during normal gestation in dogs
    Blanco, Paula G.
    Tortora, Mariana
    Rodriguez, Raul
    Arias, Daniel O.
    Gobello, Cristina
    [J]. VETERINARY JOURNAL, 2011, 190 (01) : 154 - 159
  • [6] Contrast-enhanced ultrasound features of malignant focal liver masses in dogs
    Burti, Silvia
    Zotti, Alessandro
    Rubini, Giuseppe
    Orlandi, Riccardo
    Bargellini, Paolo
    Bonsembiante, Federico
    Banzato, Tommaso
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] Diagnostic Value of Transcervical Endometrial Biopsies in Domestic Dogs Compared with Full-Thickness Uterine Sections
    Christensen, B. W.
    Schlafer, D. H.
    Agnew, D. W.
    Wang, C.
    Kozlowski, C.
    Asa, C. S.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2012, 47 : 342 - 346
  • [8] Interleukin 6 induces the expression of vascular endothelial growth factor
    Cohen, T
    Nahari, D
    Cerem, LW
    Neufeld, G
    Levi, BZ
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (02) : 736 - 741
  • [9] Reproductive Ultrasound of the Bitch and Queen
    Davidson, Autumn P.
    Baker, Tomas W.
    [J]. TOPICS IN COMPANION ANIMAL MEDICINE, 2009, 24 (02) : 55 - 63
  • [10] Cystic endometrial hyperplasia-pyometra complex in the bitch: Should the two entities be disconnected
    De Bosschere, H
    Ducatelle, R
    Vermeirsch, H
    Van den Broeck, W
    Coryn, M
    [J]. THERIOGENOLOGY, 2001, 55 (07) : 1509 - 1519