Modeling and Control of the Starter Motor and Start-Up Phase for Gas Turbines

被引:8
作者
Jafari, Soheil [1 ]
Fashandi, Seyed Alireza Miran [2 ]
Nikolaidis, Theoklis [1 ]
机构
[1] Cranfield Univ, Sch Aerosp Transport & Mfg, Prop Engn Ctr, Cranfield MK43 0AL, Beds, England
[2] Iran Univ Sci & Technol, Dept Mech Engn, Tehran 1684613114, Iran
关键词
industrial gas turbine; electric starter; cold start-up phase; dynamic modeling; bond graph; mechatronic approach; integrated modeling approach; SIMULATION;
D O I
10.3390/electronics8030363
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Improving the performance of industrial gas turbines has always been at the focus of attention of researchers and manufacturers. Nowadays, the operating environment of gas turbines has been transformed significantly respect to the very fast growth of renewable electricity generation where gas turbines should provide a safe, reliable, fast, and flexible transient operation to support their renewable partners. So, having a reliable tools to predict the transient behavior of the gas turbine is becoming more and more important. Regarding the response time and flexibility, improving the turbine performance during the start-up phase is an important issue that should be taken into account by the turbine manufacturers. To analyze the turbine performance during the start-up phase and to implement novel ideas so as to improve its performance, modeling, and simulation of an industrial gas turbine during cold start-up phase is investigated this article using an integrated modular approach. During this phase, a complex mechatronic system comprised of an asynchronous AC motor (electric starter), static frequency converter drive, and gas turbine exists. The start-up phase happens in this manner: first, the clutch transfers the torque generated by the electric starter to the gas turbine so that the turbine reaches a specific speed (cranking stage). Next, the turbine spends some time at this speed (purging stage), after which the turbine speed decreases, sparking stage begins, and the turbine enters the warm start-up phase. It is, however, possible that the start-up process fails at an intermediate stage. Such unsuccessful start-ups can be caused by turbine vibrations, the increase in the gradients of exhaust gases, or issues with fuel spray nozzles. If, for any reason, the turbine cannot reach the self-sustained speed and the speed falls below a certain threshold, the clutch engages once again with the turbine shaft and the start-up process is repeated. Consequently, when modeling the start-up phase, we face discontinuities in performance and a system with variable structure owing to the existence of clutch. Modeling the start-up phase, which happens to exist in many different fields including electric and mechanical application, brings about problems in numerical solutions (such as algebraic loop). Accordingly, this study attempts to benefit from the bond graph approach (as a powerful physical modeling approach) to model such a mechatronic system. The results confirm the effectiveness of the proposed approach in detailed performance prediction of the gas turbine in start-up phase.
引用
收藏
页数:25
相关论文
共 43 条
[31]   Dynamic modeling of a full-scale anaerobic mesophilic digester start-up process for the treatment of primary sludge [J].
Yang, Wenwen ;
Young, Stephanie ;
Munoz, Alex ;
Palmarin, Matthew J. .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2019, 7 (03)
[32]   Transient gas-liquid flow phenomena in M-shaped jumper of subsea gas production systems during start-up operation [J].
Yurishchev, A. ;
Ravid, R. B. ;
Ullmann, A. ;
Brauner, N. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2024, 171
[33]   Modeling of wellbore dynamics of a CO2 injector during transient well shut-in and start-up operations [J].
Li, Xiaolu ;
Xu, Ruina ;
Wei, Lingli ;
Jiang, Peixue .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2015, 42 :602-614
[34]   Study on start-up characteristics of H-Darrieus vertical axis wind turbines comprising NACA 4-digit series blade airfoils [J].
Asr, Mandi Torabi ;
Nezhad, Erfan Zal ;
Mustapha, Faizal ;
Wiriadidjaja, Surjatin .
ENERGY, 2016, 112 :528-537
[35]   NUMERICAL ANALYSIS OF CO2 TRANSIENT BEHAVIOR IN THE GAS COOLER DURING VARIABLE START-UP CONDITIONS OF A TRANSCRITICAL REFRIGERATION SYSTEM [J].
Ituna-Yudonago, J. F. ;
Belman-Flores, J. M. ;
Elizalde-Blancas, F. ;
Perez-Garcia, V. ;
Garcia-Valladares, O. ;
Carvajal-Mariscal, I. .
REVISTA MEXICANA DE INGENIERIA QUIMICA, 2019, 18 (03) :1101-1118
[36]   Fault detection of industrial large-scale gas turbine for fuel distribution characteristics in start-up procedure using artificial neural network method [J].
Park, Yeseul ;
Choi, Minsung ;
Choi, Gyungmin .
ENERGY, 2022, 251
[37]   Generating a virtual physical model through measurement data and reverse engineering: Applying a performance prediction model for an industrial gas turbine during start-up [J].
Kim, Sangjo .
APPLIED THERMAL ENGINEERING, 2023, 232
[38]   Start-Up of a Solid Oxide Fuel Cell System with a View to Materials Science-Related Aspects, Control and Thermo-Mechanical Stresses [J].
Colombo, Konrad W. Eichhorn ;
Kharton, Vladislav V. .
CRYSTALS, 2021, 11 (07)
[39]   Dynamic process modeling and hybrid intelligent control of ethylene copolymerization in gas phase catalytic fluidized bed reactors [J].
Abbasi, Mohammad Reza ;
Shamiri, Ahmad ;
Hussain, Mohamed Azlan ;
Kaboli, Seyed Hamidreza Aghay .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2019, 94 (08) :2433-2451
[40]   Modeling and simulation of control system for 3-phase variable-reluctance stepper motor [J].
Liu Lihua ;
Li Hong .
FOURTH INTERNATIONAL SEMINAR ON MODERN CUTTING AND MEASUREMENT ENGINEERING, 2011, 7997