Cauda equina syndrome caused by the application of DuraSeal™ in a microlaminectomy surgery: A case report

被引:3
作者
Yeh, Kuei-Lin [1 ,2 ,3 ]
Wu, Szu-Hsien [4 ]
Fuh, Chiou-Shann [2 ]
Huang, Yi-Hung [1 ]
Chen, Chu-Song [2 ]
Wu, Shing-Sheng [5 ]
机构
[1] Ditmanson Med Fdn Chia Yi Christian Hosp, Dept Orthopaed, Chia Yi City 600, Taiwan
[2] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 10617, Taiwan
[3] WuFeng Univ, Dept Long Term Care & Management, Minxiong Township 621303, Chiayi County, Taiwan
[4] Taipei Vet Gen Hosp, Dept Phys Med & Rehabil, Taipei 11217, Taiwan
[5] Shin Kong Wu Ho Su Mem Hosp, Dept Orthopaed, 95 Wenchang Rd, Taiepi 111, Taiwan
关键词
Cauda equina syndrome; DuraSeal; Microlaminectomy; Spinal stenosis; Case report; DURAL TEARS; HYDROGEL; REPAIR; COMPRESSION; MANAGEMENT; DUROTOMY;
D O I
10.12998/wjcc.v10.i30.11178
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The management of dural tears is important. While a massive dura can be repaired with absorbable suture lines, cerebrospinal fluid leakage can be attenuated by dural sealant when an unintended tiny durotomy occurs intraoperatively. DuraSeal is often used because it can expand to seal tears. This case emphasizes the need for caution when DuraSeal is used as high expansion can cause complications following microlaminectomy. CASE SUMMARY A 77-year-old woman presented with L2/3 and L3/4 lateral recess stenosis. She underwent microlaminectomy, foraminal decompression, and disk height restoration using an IntraSPlNE (R) device. A tiny incident durotomy occurred intraoperatively and was sealed using DuraSeallm. However, decreased muscle power, urinary incontinence, and absence of anal reflexes were observed postoperatively. Emergent magnetic resonance imaging revealed fluid collection causing thecal sac indentation and central canal compression. Surgical exploration revealed that the gel-like DuraSeal had entrapped the hema toma and, consequently, compressed the thecal sac and nerve roots. While we removed all DuraSeatim and exposed the nerve root, the patient's neurological function did not recover postoperatively. CONCLUSION DuraSeal expansion must not be underestimated. Changes in neurological status require investigation for cauda equine syndrome due to expansion.
引用
收藏
页码:11178 / 11184
页数:7
相关论文
共 25 条
[1]  
Alvarez JA, 1998, AM FAM PHYSICIAN, V57, P1825
[2]  
Bellen P, 1992, Acta Orthop Belg, V58, P236
[3]   Cauda equina syndrome caused by retained hemostatic agents [J].
Bessette, Matthew C. ;
Mesfin, Addisu .
JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (09) :1518-1520
[4]   Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair - Technical note [J].
Black, P .
JOURNAL OF NEUROSURGERY, 2002, 96 (02) :250-252
[5]   Hydrogel-induced cervicomedullary compression after posterior fossa decompression for Chiari malformation - Case report [J].
Blackburn, Spiros L. ;
Smyth, Matthew D. .
JOURNAL OF NEUROSURGERY, 2007, 106 (04) :302-304
[6]   Use of a novel absorbable hydrogel for augmentation of dural repair: Results of a preliminary clinical study [J].
Boogaarts, JD ;
Grotenhuis, JA ;
Bartels, RHMA ;
Beems, T .
NEUROSURGERY, 2005, 57 (01) :146-151
[7]  
Brodbelt AR, 2002, ANN ROY COLL SURG, V84, P97
[8]  
Di Vitantonio Hambra, 2016, Surg Neurol Int, V7, pS463, DOI 10.4103/2152-7806.185777
[9]   Accuracy of diagnosis on CT scan of Surgicel® Fibrillar: results of a prospective blind reading study [J].
Frati, Albane ;
Thomassin-Naggara, Isabelle ;
Bazot, Marc ;
Darai, Emile ;
Rouzier, Roman ;
Chereau, Elisabeth .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2013, 169 (02) :397-401
[10]   Dural tears in primary decompressive lumbar surgery. Is primary repair necessary for a good outcome? [J].
Grannum, Sean ;
Patel, Mohammed Shakil ;
Attar, Fahad ;
Newey, Martyn .
EUROPEAN SPINE JOURNAL, 2014, 23 (04) :904-908