Quantitative profiling of bile acids in biofluids and tissues based on accurate mass high resolution LC-FF-MS: Compound class targeting in a metabolomics workflow

被引:89
作者
Bobeldijk, Ivana [1 ]
Hekman, Maarten [1 ]
de Vries-van der Weij, Jitske [2 ,3 ]
Coulier, Leon [1 ]
Ramaker, Raymond [1 ]
Kleemann, Robert [2 ,4 ]
Kooistra, Teake [2 ]
Rubingh, Carina [1 ]
Freidig, Andreas [1 ]
Verheij, Elwin [1 ]
机构
[1] TNO Qual Life, NL-3700 AJ Zeist, Netherlands
[2] TNO Qual Life, NL-2333 CK Leiden, Netherlands
[3] Leiden Univ, Ctr Med, Dept Human & Clin Genet, Leiden, Netherlands
[4] Leiden Univ, Ctr Med, Dept Vasc Surg, Leiden, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 871卷 / 02期
关键词
metabolomics; targeted metabolite profiling; accurate mass; high performance liquid chromatography; bile acids; body fluids; tissues;
D O I
10.1016/j.jchromb.2008.05.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a sensitive, generic method for quantitative profiling of bile acids and other endogenous metabolites in small quantities of various biological fluids and tissues. The method is based on a straightforward sample preparation, separation by reversed-phase high performance liquid-chromatography mass spectrometry (HPLC-MS) and electrospray ionisation in the negative ionisation mode (ESI-). Detection is performed in full scan using the linear ion trap Fourier transform mass spectrometer (LTQ-FTMS) generating data for many (endogenous) metabolites, not only bile acids. A validation of the method in urine, plasma and liver was performed for 17 bile acids including their taurine, sulfate and glycine conjugates. The method is linear in the 0.01-1 mu M range. The accuracy in human plasma ranges from 74 to 113%, in human urine 77 to 104% and in mouse liver 79 to 140%. The precision ranges from 2 to 20% for pooled samples even in studies with large number of samples (n > 250). The method was successfully applied to a multi-compartmental APOE*3-Leiden mouse study, the main goal of which was to analyze the effect of increasing dietary cholesterol concentrations on hepatic cholesterol homeostasis and bile acid synthesis. Serum and liver samples from different treatment groups were profiled with the new method. Statistically significant differences between the diet groups were observed regarding total as well as individual bile acid concentrations. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:306 / 313
页数:8
相关论文
共 19 条
[1]   High sensitive analysis of rat serum bile acids by liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Ando, M ;
Kaneko, T ;
Watanabe, R ;
Kikuchi, S ;
Goto, T ;
Iida, T ;
Hishinuma, T ;
Mano, N ;
Goto, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (05) :1179-1186
[2]   Large-scale human metabolomics studies: A strategy for data (pre-) processing and validation [J].
Bijlsma, S ;
Bobeldijk, L ;
Verheij, ER ;
Ramaker, R ;
Kochhar, S ;
Macdonald, IA ;
van Ommen, B ;
Smilde, AK .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :567-574
[3]  
Budai K, 1997, J LIPID RES, V38, P1906
[4]   Differentiated quantification of human bile acids in serum by high-performance liquid chromatography-tandem mass spectrometry [J].
Burkard, I ;
von Eckardstein, A ;
Rentsch, KM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2) :147-159
[5]   Bile acid regulation of gene expression: Roles of nuclear hormone receptors [J].
Chiang, JYL .
ENDOCRINE REVIEWS, 2002, 23 (04) :443-463
[6]   Identification of a novel conjugate in human urine: bile acid acyl galactosides [J].
Goto, T ;
Shibata, A ;
Sasaki, D ;
Suzuki, N ;
Hishinuma, T ;
Kakiyama, G ;
Iida, T ;
Mano, N ;
Goto, J .
STEROIDS, 2005, 70 (03) :185-192
[7]   LC/ESI-tandem mass spectrometric determination of bile acid 3-sulfates in human urine 3β-sulfooxy-12α-hydroxy-5β-cholanoic acid is an abundant nonamidated sulfate [J].
Goto, Takaaki ;
Myint, Khin Than ;
Sato, Koichi ;
Wada, Osamu ;
Kakiyama, Genta ;
Iida, Takashi ;
Hishinuma, Takanori ;
Mano, Nariyasu ;
Goto, Junichi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2) :69-77
[8]   Contemporary clinical usage of LC/MS: Analysis of biologically important carboxylic acids [J].
Johnson, DW .
CLINICAL BIOCHEMISTRY, 2005, 38 (04) :351-361
[9]  
KARLAGANIS G, 1980, J LIPID RES, V21, P377
[10]   Determination of underivatised sterols and bile acid trimethyl silyl ether methyl esters by gas chromatography-mass spectrometry-single ion monitoring in faeces [J].
Keller, S ;
Jahreis, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2) :199-207