Determination of metallic impurities in U3O8 using energy dispersive X-ray fluorescence spectrometry

被引:14
作者
Natarajan, V. [1 ]
Dhawale, B. A. [1 ]
Rajeswari, B. [1 ]
Hon, N. S. [1 ]
Thulasidas, S. K. [1 ]
Porwal, N. K. [1 ]
Godbole, S. V. [1 ]
Manchanda, V. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Radiochem, Bombay 400085, Maharashtra, India
关键词
EDXRF; metallic impurity; nuclear fuel;
D O I
10.1016/j.sab.2008.04.021
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In order to examine the capability of energy dispersive X-ray fluorescence spectrometry for the determination of some common metallic impurities in nuclear grade U3O8 matrix, a series of synthetic U3O8 standards, containing impurities such as Ca, Co, Cr, Cu, Fe, Mn, Mo, Ni V, W and Zn in the concentration range, 100-1000 mu g/g, were prepared. Using these standards, calibration curves were set up for different elements after optimizing the spectrometer parameters. Two synthetic samples and five reference standards obtained through an inter-laboratory comparison exercise within analytical laboratories of Department of Atomic Energy, India were analyzed to evaluate the performance of the newly developed analytical methods. The estimates for most of the analytes were in good agreement with the added amounts. The method is fast, since it requires no chemical treatment. The method has good precision for the analytes determined. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:817 / 819
页数:3
相关论文
共 18 条
[1]   EFFECT OF SOME IMPORTANT SAMPLE PARAMETERS ON THE X-RAY-FLUORESCENCE DETERMINATION OF IMPURITIES IN PURE MATERIALS - DETERMINATION OF CA, Y, GD AND TH IN URANIUM [J].
AGRAWAL, RM ;
KAPOOR, SK .
X-RAY SPECTROMETRY, 1987, 16 (02) :81-85
[2]   DETERMINATION OF IMPURITIES IN NUCLEAR-GRADE URANIUM-COMPOUNDS BY X-RAY-FLUORESCENCE SPECTROMETRY [J].
ALAMMAR, AS ;
ALI, FH .
X-RAY SPECTROMETRY, 1992, 21 (05) :211-213
[3]   Chemical separation and ICP-AES determination of 22 metallic elements in U and Pu matrices using cyanex-923 extractant and studies on stripping of U and Pu [J].
Argekar, AA ;
Kulkarni, MJ ;
Mathur, JN ;
Page, AG .
TALANTA, 2002, 56 (04) :591-601
[4]   Glow discharge spectrometry for the characterization of nuclear and radioactively contaminated environmental samples [J].
Betti, M ;
de las Heras, LA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (09) :1359-1376
[5]   Alteration and breakdown of xenotime-(Y) and monazite-(Ce) in granitic rocks of the Western Carpathians, Slovakia [J].
Broska, I ;
Williams, CT ;
Janák, M ;
Nagy, G .
LITHOS, 2005, 82 (1-2) :71-83
[6]  
CAMP DC, 1980, ADV XRAY ANAL, V23, P163
[7]  
*DAE, 2002, INT LAB COMP EXP ILC
[8]  
DIXIT RM, 1969, FRESEN J ANAL CHEM, V280, P201
[9]   IN-LINE DETERMINATION OF U, PU AND NP IN PROCESS STREAMS BY ENERGY-DISPERSIVE X-RAY-FLUORESCENCE ANALYSIS (EDXRF) [J].
HOFMANN, T ;
HOFFMANN, P ;
LIESER, KH .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1984, 82 (01) :201-204
[10]  
JAYADEVAN NC, 1971, XRAY FLUORESCENCE AN, V570