Stator Flux Active Damping Methods for Field-Oriented Doubly Fed Induction Generator

被引:34
作者
Marques, G. D. [1 ]
Sousa, Duarte M. [1 ]
机构
[1] Univ Tecn Lisboa, Dept Elect & Comp Engn, P-1049001 Lisbon, Portugal
关键词
Doubly fed induction generator (DFIG); flux stabilization; induction generator;
D O I
10.1109/TEC.2012.2204887
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The doubly fed induction generator is characterized by natural stator flux oscillations with small damping. It has an unstable region when it is controlled with stator flux orientation with impressed rotor currents. Several techniques can be used for the stabilization and damping of this system. This paper describes, analyses, and compares three methods. The first method consists in lowering the bandwidth of the rotor current controllers. It has the disadvantage of allowing high rotor-disturbance currents during stator flux disturbances. The second method, the back-ims method, uses higher bandwidth control loops and corrects the direct rotor current reference proportionally to the derivative of the flux. It has good performances in steady state but uses considerable additional rotor currents to damp the system when transients occur. The third method, the two-axes damping system, is based on the correction of the dq rotor current references proportionally to the variations of the system variables, i.e., the stator flux and the so-called a angle. When compared with the back-ims method, the two-axes damping method uses smaller additional damping currents. Experimental verification based on a small laboratory prototype is presented.
引用
收藏
页码:799 / 806
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1996, CONTROL ELECT DRIVES
[2]   Direct power control of grid-connected wound rotor induction machine without rotor position sensors [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2001, 16 (03) :390-399
[3]  
Heller H., 1997, P EUR C POW EL APPL, P2707
[4]  
KELBER CR, 2003, ELECT POTENCIA, V8, P33
[5]  
Kelber M. C. R., 2001, P EUR C POW EL APPL, pP1
[6]   Doubly fed induction generator model for transient stability analysis [J].
Ledesma, P ;
Usaola, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :388-397
[7]  
Liu CW, 2001, ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, P1203, DOI 10.1109/ICEMS.2001.971897
[8]  
Lopez Jesus, 2008, 2008 IEEE International Symposium on Industrial Electronics (ISIE 2008), P2456, DOI 10.1109/ISIE.2008.4677148
[9]   Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips [J].
Lopez, Jesus ;
Gubia, Eugenio ;
Olea, Eneko ;
Ruiz, Josu ;
Marroyo, Luis .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) :4246-4254
[10]  
Marques GD, 2007, POWERENG2007: INTERNATIONAL CONFERENCE ON POWER ENGINEERING - ENERGY AND ELECTRICAL DRIVES PROCEEDINGS, VOLS 1 & 2, P765