Radiation protection during fluoroscopic interventions

被引:1
|
作者
Ammon, J. [1 ]
Loose, R. [1 ]
机构
[1] Paracelsus Med Privatuniv, Inst Med Phys, Klinikum Nurnberg, Prof Ernst Nathan Str 1, D-90419 Nurnberg, Germany
来源
RADIOLOGIE | 2022年 / 62卷 / 12期
关键词
X-rays; Diagnostic reference levels; Radiation monitoring; Radiation exposure; Dose limit values; RADIOLOGY;
D O I
10.1007/s00117-022-01087-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Facts and figures about the frequencies of fluoroscopically guided interventions (FGI), typical patient exposures and occupational exposures are listed. Limits of radiation exposure do not exist for patients but only for occupationally exposed medical personnel. Measures for radiation protection of patients and personnel are explained. Nearly all technical radiation protection measures for patients also protect the personnel. To reduce the exposure of medical personnel, radiation protection equipment should be attached to the X-ray modality and personal radiation protection equipment should be worn. The diagnostic reference values and the obligation to report incidents, including the reporting criteria, are explained. The radiation protection of patients and personnel for FGI in Germany is well regulated by diagnostic reference values, reporting criteria, prescribed or recommended protective measures, personal dosimetry and the obligation to involve medical physics experts.
引用
收藏
页码:1079 / 1088
页数:10
相关论文
共 50 条
  • [31] OPTIMISATION OF OCCUPATIONAL RADIATION PROTECTION IN IMAGE-GUIDED INTERVENTIONS: EXPLORING VIDEO RECORDINGS AS A TOOL IN THE PROCESS
    Almen, Anja
    Sandblom, Viktor
    Rystedt, Hans
    von Wrangel, Alexa
    Ivarsson, Jonas
    Bath, Magnus
    Lundh, Charlotta
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 425 - 429
  • [32] A New Device for Protection from Radiation Exposure during Catheter Ablation
    Kowase, Shinya
    Kurosaki, Kenji
    Miyamoto, Mihoko
    Oginosawa, Yasushi
    Sugiyasu, Aiko
    Kubota, Shoichi
    Nogami, Akihiko
    JOURNAL OF ARRHYTHMIA, 2009, 25 (02) : 77 - 80
  • [33] Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring
    Sailer, Anna M.
    Vergoossen, Laura
    Paulis, Leonie
    van Zwam, Willem H.
    Das, Marco
    Wildberger, Joachim E.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) : 1756 - 1762
  • [34] Fluoroscopic practice patterns in pediatric radiology during pregnancy
    Blumfield, Einat
    PEDIATRIC RADIOLOGY, 2019, 49 (07) : 849 - 850
  • [35] Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
    Kim, Cho Long
    Jeong, Hae Chang
    Kim, Jae Hun
    MEDICINE, 2023, 102 (48) : E36447
  • [36] DOSE REDUCTION DURING FLUOROSCOPIC PLACEMENT OF FEEDING TUBES
    RUDIN, S
    BEDNAREK, DR
    MILLER, JA
    RADIOLOGY, 1991, 178 (03) : 647 - 651
  • [37] Protection against ionizing radiation by leaded glass googles during interventional cardiology
    Zett-Lobos, Claudio
    Vera-Munoz, Felipe
    Arriola-Alvarez, Katerina
    Diaz-Ramos, Oscar
    Gamarra, Jorge
    Fernandez-Palomo, Cristian
    Merello, Lorenzo
    Mora, Alex D.
    Gutierrez, Alejandro
    Catalan-Reyes, Monica
    Ramos-Avasola, Sergio
    REVISTA MEDICA DE CHILE, 2013, 141 (01) : 63 - 69
  • [38] Reduction of radiation exposure during coronary interventions using coronary roadmap imaging software
    Ting, Chien -Yi
    Lin, Chun-Chih
    Tang, Kuo-Ting
    Yao, Huan-Chung
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [39] Radiation protection knowledge among radiologists in northwest Spain
    Macia-Suarez, D.
    Sanchez-Rodriguez, E.
    RADIOLOGIA, 2018, 60 (04): : 318 - 323
  • [40] Radiation exposure of the radiologist's eye lens during CT-guided interventions
    Heusch, Philipp
    Kroepil, Patric
    Buchbender, Christian
    Aissa, Joel
    Lanzman, Rotem S.
    Heusner, Till A.
    Ewen, Klaus
    Antoch, Gerald
    Fuerst, Guenther
    ACTA RADIOLOGICA, 2014, 55 (01) : 86 - 90