Radiation protection during fluoroscopic interventions

被引:1
|
作者
Ammon, J. [1 ]
Loose, R. [1 ]
机构
[1] Paracelsus Med Privatuniv, Inst Med Phys, Klinikum Nurnberg, Prof Ernst Nathan Str 1, D-90419 Nurnberg, Germany
来源
RADIOLOGIE | 2022年 / 62卷 / 12期
关键词
X-rays; Diagnostic reference levels; Radiation monitoring; Radiation exposure; Dose limit values; RADIOLOGY;
D O I
10.1007/s00117-022-01087-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Facts and figures about the frequencies of fluoroscopically guided interventions (FGI), typical patient exposures and occupational exposures are listed. Limits of radiation exposure do not exist for patients but only for occupationally exposed medical personnel. Measures for radiation protection of patients and personnel are explained. Nearly all technical radiation protection measures for patients also protect the personnel. To reduce the exposure of medical personnel, radiation protection equipment should be attached to the X-ray modality and personal radiation protection equipment should be worn. The diagnostic reference values and the obligation to report incidents, including the reporting criteria, are explained. The radiation protection of patients and personnel for FGI in Germany is well regulated by diagnostic reference values, reporting criteria, prescribed or recommended protective measures, personal dosimetry and the obligation to involve medical physics experts.
引用
收藏
页码:1079 / 1088
页数:10
相关论文
共 50 条
  • [21] Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre study
    Schmitz, Daniel
    Vogl, Thomas
    Nour-Eldin, Nour-Eldin Abdelrehim
    Radeleff, Boris
    Kroeger, Jens-Christian
    Mahnken, Andreas H.
    Ittrich, Harald
    Gehl, Hans-Bjoern
    Plessow, Bernd
    Boettcher, Joachim
    Tacke, Josef
    Wispler, Markus
    Rosien, Ulrich
    Schorr, Wolfgang
    Joerdens, Markus
    Glaser, Nicolas
    Fuchs, Erik-Sebastian
    Tal, Andrea
    Friesenhahn-Ochs, Bettina
    Leimbach, Thomas
    Hoepner, Lars
    Weber, Marko
    Goelder, Stefan
    Boehmig, Michael
    Hetjens, Svetlana
    Rudi, Jochen
    Schegerer, Alexander
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3390 - 3400
  • [22] Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
    Bruce, Angus
    De, Chiranjit
    Golmohamad, Ramez
    Habeebulah, Awais
    Sikand, Manoj
    Gulati, Aashish
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [23] Let's talk about radiation dose and radiation protection in children
    Granata, Claudio
    Sofia, Carmelo
    Francavilla, Mariantonietta
    Kardos, Marek
    Kasznia-Brown, Joanna
    Nievelstein, Rutger A. J.
    Olteanu, Bogdan Stefan
    Owens, Catherine
    Salerno, Sergio
    Sorantin, Erich
    Apine, Ilze
    PEDIATRIC RADIOLOGY, 2025, 55 (03) : 386 - 396
  • [24] Reduction of Radiation Exposure by the Use of Fluoroscopic Guidance in Transpedicular Instrumentation
    Hart, R.
    Komzak, M.
    Barta, R.
    Okal, F.
    Srutkova, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (05) : 447 - 450
  • [25] Radiation protection provided by tungsten bismuth caps during interventional cardiology
    Ramos-Avasola, Sergio
    Diaz, Natalia
    Roldan, Reynaldo
    Gamarra, Jorge
    Catalan, Monica
    REVISTA MEDICA DE CHILE, 2016, 144 (07) : 837 - 843
  • [26] Radiation Dose of Patients in Fluoroscopically Guided Interventions: an Update
    Paulo, Graciano
    Bartal, Gabriel
    Vano, Eliseo
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (06) : 842 - 848
  • [27] Evaluation of radiation exposure from fluoroscopic examination in small animal veterinary staff using thermoluminescent dosimeters
    An, Jeongsu
    Lim, Sohee
    Lee, Seunghee
    Kim, Hyeona
    Min, Kyungjun
    Cho, Youngkwon
    Lee, Kichang
    VETERINARNI MEDICINA, 2019, 64 (06) : 266 - 270
  • [28] Performance of a Radiation Protection Cabin During Implantation of Pacemakers or Cardioverter Defibrillators
    Ploux, Sylvain
    Ritter, Philippe
    Haissaguerre, Michel
    Clementy, Jacques
    Bordachar, Pierre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (04) : 428 - 430
  • [29] Evaluation of Radiation Exposure of Medical Staff During CT-Guided Interventions
    Rathmann, Nils
    Haeusler, Uwe
    Diezler, Patricius
    Weiss, Christel
    Kostrzewa, Michael
    Sadick, Maliha
    Schoenberg, Stefan O.
    Diehl, Steffen J.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (01) : 82 - 89
  • [30] A Cadaveric Simulation Study of Radiation Exposure to the Surgical Team during Fluoroscopic Spinal Surgery: How Much Are We Exposed?
    Yamashita, Kazuta
    Tamaki, Yasuaki
    Nakajima, Daiki
    Omichi, Yasuyuki
    Takahashi, Yoshinori
    Takai, Michihiro
    Goto, Tomohiro
    Hayashi, Hiroaki
    Higashino, Kosaku
    Tsuruo, Yoshihiro
    Sairyo, Koichi
    SPINE SURGERY AND RELATED RESEARCH, 2023, 7 (04): : 341 - 349