Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers

被引:67
作者
Wu, Jie [1 ]
Yan, Feng [2 ]
Zhang, Xiaoqing [3 ]
Yan, Yuetian [1 ]
Tang, Jinhai [2 ]
Ju, Huangxian [1 ,3 ]
机构
[1] Nanjing Univ, Dept Chem, Minist Educ China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing, Peoples R China
[3] Chongqing Med Univ, Dept Lab Med, Minist Educ China, Key Lab Lab Med Diagnost, Chongqing, Peoples R China
关键词
D O I
10.1373/clinchem.2007.102350
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: A reagentless sensor array for simultaneous multianalyte testing (SMAT) may enable accurate diagnosis and be applicable for point-of-care testing. We developed a disposable reagentless immunosensor array for simple immunoassay of panels of tumor markers. METHODS: We carried out SMAT with a direct capture format, in which colloidal gold nanoparticles with bound horseradish peroxidase (HRP)-labeled antibodies were immobilized on screen-printed carbon electrodes with biopolymer/sol-gel to trap their corresponding antigens from sample solution. Upon formation of immunocomplex, the direct electrochemical signal of the HRP decreased owing to increasing spatial blocking, and the analytes could be simultaneously determined by monitoring the signal changes. RESULTS: The proposed reagentless immunosensor array allowed simultaneous detection of carcinoma antigen 153, carcinoma antigen 125, carbohydrate antigen 199, and carcinoembryonic antigen in clinical serum samples in the ranges of 0.4-140 kU/L, 0.5-330 kU/L, 0.8-190 kU/L, and 0.1-44 mu g/L, respectively, with detection limits of 0.2 kU/L, 0.5 kU/L, 0.3 kU/L, and 0.1 mu g/L corresponding to the signals 3 SD above the mean of a zero standard. The interassay imprecision of the arrays was <9.5%, and they were stable for 35 days. The positivity detection rate of panels of tumor markers was >95.5% for 95 cases of cancer-positive sera. CONCLUSIONS: The immunosensor array provides a SMAT with short analytical time, small sampling volume, no need for substrate, and, no between-electrode cross-talk. This method not only proved the capability of the array in point-of-care testing, but also allowed simultaneous testing of several tumor markers. (C) 2008 American Association for Clinical Chemistry.
引用
收藏
页码:1481 / 1488
页数:8
相关论文
共 36 条
[11]   Electrochemistry and electrocatalysis with heme proteins in chitosan biopolymer films [J].
Huang, H ;
Hu, NF ;
Zeng, YH ;
Zhou, G .
ANALYTICAL BIOCHEMISTRY, 2002, 308 (01) :141-151
[12]   Label-free electrochemical immunoassay for the detection of human chorionic gonadotropin hormone [J].
Kerman, Kagan ;
Nagatani, Naoki ;
Chikae, Miyuki ;
Yuhi, Teruko ;
Takamura, Yuzuru ;
Tamiya, Eiichi .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5612-5616
[13]   Automated microarray system for the simultaneous detection of antibiotics in milk [J].
Knecht, BG ;
Strasser, A ;
Dietrich, R ;
Märtlbauer, E ;
Niessner, R ;
Weller, MG .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :646-654
[14]   Electrochemical protein chip with arrayed immunosensors with antibodies immobilized in a plasma-polymerized film [J].
Kojima, K ;
Hiratsuka, A ;
Suzuki, H ;
Yano, K ;
Ikebukuro, K ;
Karube, I .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1116-1122
[15]  
KRICKA LJ, 1992, CLIN CHEM, V38, P327
[16]   Electrochemical coding for multiplexed immunoassays of proteins [J].
Liu, GD ;
Wang, J ;
Kim, J ;
Jan, MR ;
Collins, GE .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7126-7130
[17]   Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode [J].
Liu, SQ ;
Ju, HX .
ANALYTICAL BIOCHEMISTRY, 2002, 307 (01) :110-116
[18]   Development of biosensors for cancer clinical testing [J].
Rasooly, A ;
Jacobson, J .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (10) :1851-1858
[19]   Antibody arrays: Technical considerations and clinical applications in cancer [J].
Sanchez-Carbayo, Marta .
CLINICAL CHEMISTRY, 2006, 52 (09) :1651-1659
[20]   Point-of-care biosensor systems for cancer diagnostics/prognostics [J].
Soper, SA ;
Brown, K ;
Ellington, A ;
Frazier, B ;
Garcia-Manero, G ;
Gau, V ;
Gutman, SI ;
Hayes, DF ;
Korte, B ;
Landers, JL ;
Larson, D ;
Ligler, F ;
Majumdar, A ;
Mascini, M ;
Nolte, D ;
Rosenzweig, Z ;
Wang, J ;
Wilson, D .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (10) :1932-1942