Improving the fixation of an artificial intervertebral disc

被引:6
作者
Eijkelkamp, MF
Hayen, J
Veldhuizen, AG
Van Horn, JR
Verkerke, GJ
机构
[1] Univ Groningen, Dept Biomed Engn, NL-9713 AV Groningen, Netherlands
[2] Univ Groningen Hosp, Dept Orthoped, Groningen, Netherlands
关键词
artificial intervertebral disc; lumbar spine; development; fixation;
D O I
10.1177/039139880202500412
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The fixation of an artificial intervertebral disc has been studied especially with respect to the dimensions, the convexity of the endplates and the size of the fixation elements. From literature and cadaveric vertebrae, the dimensions and shape of the lumbar vertebral endplates were determined and the dimensions of fixation ribs for the artificial intervertebral disc were calculated. To withstand shear forces and prevent dislocation, two sagittal ribs, each 3.5 mm in height and at least 20 mm in length and four transversal ribs, each 1.5 mm in height and with a total length of 60 mm are sufficient. A range of five different sagittal diameters was selected as sufficient for all patients. At least 72.6% of the endplate of the vertebrae is covered. A convexity with a radius of 140 mm limits the gap to 0.62 mm.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 18 条
  • [1] THE MECHANICAL FUNCTION OF THE LUMBAR APOPHYSEAL JOINTS
    ADAMS, MA
    HUTTON, WC
    [J]. SPINE, 1983, 8 (03) : 327 - 330
  • [2] MORPHOMETRIC ANALYSIS OF VERTEBRAE AND INTERVERTEBRAL DISKS AS A BASIS OF DISK REPLACEMENT
    AHARINEJAD, S
    BERTAGNOLI, R
    WICKE, K
    FIRBAS, W
    SCHNEIDER, B
    [J]. AMERICAN JOURNAL OF ANATOMY, 1990, 189 (01): : 69 - 76
  • [3] AMONOOKUOFI HS, 1991, J ANAT, V175, P159
  • [4] A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE
    BERRY, JL
    MORAN, JM
    BERG, WS
    STEFFEE, AD
    [J]. SPINE, 1987, 12 (04) : 362 - 367
  • [5] Buttner-Janz K., 1992, DEV ARTIFICIAL DISC
  • [6] BIOMECHANICAL PROPERTIES OF SPINAL LIGAMENTS AND A HISTOLOGICAL STUDY OF THE SUPRASPINAL LIGAMENT IN TRACTION
    CHAZAL, J
    TANGUY, A
    BOURGES, M
    GAUREL, G
    ESCANDE, G
    GUILLOT, M
    VANNEUVILLE, G
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (03) : 167 - 176
  • [7] CURREY JD, 1984, MECH ADAPTIONS BONE
  • [8] THE EFFECT OF OPERATIVE FIT AND HYDROXYAPATITE COATING ON THE MECHANICAL AND BIOLOGICAL RESPONSE TO POROUS IMPLANTS
    DALTON, JE
    COOK, SD
    THOMAS, KA
    KAY, JF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (01) : 97 - 110
  • [9] Requirements for an artificial intervertebral disc
    Eijkelkamp, MF
    van Donkelaar, CC
    Veldhuizen, AG
    van Horn, JR
    Huyghe, JM
    Verkerke, GJ
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (05) : 311 - 321
  • [10] ARTIFICIAL DISC REPLACEMENT - PRELIMINARY-REPORT WITH A 3-YEAR MINIMUM FOLLOW-UP
    ENKER, P
    STEFFEE, A
    MCMILLIN, C
    KEPPLER, L
    BISCUP, R
    MILLER, S
    [J]. SPINE, 1993, 18 (08) : 1061 - 1070