Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners

被引:9
作者
Pesun, IJ
Hodges, J
Lai, JH
机构
[1] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Prosthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Oral Hlth Clin Res Ctr, Biostat Core, Minneapolis, MN 55455 USA
关键词
D O I
10.1067/mpr.2002.122162
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The junction between a long-term, resilient denture liner and the denture base is difficult to finish and polish due to differences in the hardness of the materials. Gaps tend to form during Finishing and polishing procedures. Purpose. This study measured the junctional gap between 2 long-term, resilient denture liners and a denture base material after different finishing and polishing procedures were performed. The surface smoothness of the 2 liner materials also was evaluated. Material and methods. Molloplast-B and an experimental, heat-polymerized methyl siloxane-resin-based denture liner were processed (according to the manufacturer's instructions) against Lucitone 199 acrylic resin. Control specimens (n=20) were 2 mm thick and flat. Experimental specimens (n=64) were fabricated with a raised center section: a 3- x 5- x 15-mm half-cylindrical ridge with a junction at the top of the cylinder between the liner material and acrylic resin. The specimens were finished with 1 of 6 types of burs and polished with different combinations of rubber-impregnated acrylic polishers, pumice, and tin oxide. The finished specimens were examined and photographed with a scanning electron microscope, and the largest gap along the liner/denture base junction on each specimen was measured. Three-way analysis of variance without replication (P<.05) and post-hoc t tests were used to analyze the data and compare groups. Results. Averaged across finishing and polishing techniques, a larger gap was recorded for the experimental liner material (22 μm) than for Molloplast-B (14 μm) (P<.00005). Qualitative evaluation suggested that the experimental liner material polished better than Molloplast-B. The smoothest surfaces were obtained when specimens were finished with fine-tooth cross-cut carbide burs and polished with both pumice and tin oxide. A comparison between polished and unpolished specimens, averaged over materials and Finishing techniques, revealed that polishing reduced gap size (P=.015). Conclusion. Within the limitations of this study, the 2 denture liners tested behaved similarly. The results suggest that the size of the gap at the liner/denture base junction may be affected by finishing and polishing techniques and vary among materials.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
[21]   Effect of Disinfection on the Bond Strength between Denture Teeth and Microwave-Cured Acrylic Resin Denture Base [J].
Matos, Adaias O. ;
Costa, Josiane O. ;
Beline, Thamara ;
Ogawa, Erika S. ;
Assuncao, Wirley G. ;
Mesquita, Marcelo F. ;
Consani, Rafael X. ;
Barao, Valentim A. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02) :169-176
[22]   Effect of long-term water immersion on the fracture toughness of denture base and reline resins [J].
Finoti, Livia Sertori ;
Machado, Ana Lucia ;
Lima Chaves, Carolina De Andrade ;
Pavarina, Ana Claudia ;
Vergani, Carlos Eduardo .
GERODONTOLOGY, 2012, 29 (02) :E858-E864
[23]   Tensile Bond Strength between Soft Liners and Two Chemically Different Denture Base Materials: Effect of Thermocycling [J].
Tugut, Faik ;
Coskun, Mehmet Emre ;
Dogan, Derya Ozdemir ;
Kirmali, Omer ;
Akin, Hakan .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (04) :319-323
[24]   Effect of Curing Cycle on the Tensile Strength of the Bond Between Heat Cured Denture Base Acrylic Resin and Acrylic Resin Denture Teeth [J].
Dalal, Ayesha ;
Juszczyk, Andrzej S. ;
Radford, David R. ;
Clark, Robert K. F. .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2009, 17 (04) :146-149
[25]   Effects of long-term cinnamaldehyde immersion on the surface roughness and color of heat-polymerized denture base resin [J].
Macedo, Lucas Oliveira ;
Campos, Debora e Silva ;
Alves, Danielle da Nobrega ;
Carreiro, Adriana da Fonte Porto ;
de Castro, Ricardo Dias ;
Batista, Andre Ulisses Dantas .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03) :521.e1-521.e8
[26]   Antimicrobial and cytotoxic effects of denture base acrylic resin impregnated with cleaning agents after long-term immersion [J].
Procopio, A. L. F. ;
da Silva, R. A. ;
Maciel, J. G. ;
Sugio, C. Y. C. ;
Soares, S. ;
Urban, V. M. ;
Neppelenbroek, K. H. .
TOXICOLOGY IN VITRO, 2018, 52 :8-13
[27]   Effect of immersion cleansers on the bond strength between a denture base resin and acrylic resin teeth [J].
Pero, Ana Carolina ;
Scavassin, Priscila Mattos ;
Perin Leite, Andressa Rosa ;
Mendoza Marin, Danny Omar ;
Paleari, Andre Gustavo ;
Compagnoni, Marco Antonio .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2013, 44 :180-183
[28]   Antimicrobial action and long-term effect of overnight denture cleansers [J].
Peracini, Amanda ;
Andrade, Ingrid Machado ;
Oliveira, Viviane Cristina ;
Macedo, Ana Paula ;
Silva-Lovato, Claudia Helena ;
Pagnano, Valeria Oliveira ;
Watanabe, Evandro ;
Oliveira Paranhos, Helena de Freitas .
AMERICAN JOURNAL OF DENTISTRY, 2017, 30 (02) :101-108
[29]   Shear bond strength between light polymerized hard reline resin and denture base resin subjected to long term water immersion [J].
Al Rifaiy, Mohammad Q. .
SAUDI DENTAL JOURNAL, 2012, 24 (01) :23-27
[30]   Strength of relined denture base polymers subjected to long-term water immersion [J].
Takahashi, Y ;
Chai, J ;
Kawaguchi, M .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (03) :205-208