High-speed data acquisition for three-dimensional x-ray and neutron computed tomography

被引:5
|
作者
Davis, AW [1 ]
Claytor, TN [1 ]
Sheats, MJ [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY II | 1999年 / 3772卷
关键词
computed tomography; neutron radiography; amorphous silicon; x-ray; nondestructive evaluation;
D O I
10.1117/12.363727
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography for nondestructive evaluation applications has been limited by system cost, resolution, and time requirements for three-dimensional data sets. FlashCT (Flat panel Amorphous Silicon High-Resolution Computed Tomography) is a system developed at Los Alamos National Laboratory to address these three problems(1). Developed around flat panel amorphous silicon detector array, FlashCT is suitable for low to medium energy x-ray and neutron computed tomography at 127-micron resolution. Overall system size is small, allowing rapid transportation to a variety of radiographic sources. System control software was developed in LabVIEW for Windows NT to allow multithreading of data acquisition, data correction, and staging motor control. The system control software simplifies data collection and allows fully automated control of the data acquisition process, leading toward remote or unattended operation. The first generation of the FlashCT Data Acquisition System was completed in August 1998, and since that rime the system has been tested using x-ray sources ranging in energy from 60 kV to 20MV. The system has also been used to collect data for thermal neutron computed tomography at the Los Alamos Neutron Science Center(LANSCE). System improvements have been proposed to provide faster data collection and greater dynamic range during data collection.
引用
收藏
页码:246 / 255
页数:10
相关论文
共 50 条
  • [1] High-speed X-ray-induced luminescence computed tomography
    Dai, Xianjin
    Cheng, Kai
    Zhao, Wei
    Xing, Lei
    JOURNAL OF BIOPHOTONICS, 2020, 13 (09)
  • [2] Three-dimensional grain fabric measurements using high-resolution X-ray computed tomography
    Ketcham, RA
    JOURNAL OF STRUCTURAL GEOLOGY, 2005, 27 (07) : 1217 - 1228
  • [3] Review of high-speed imaging with lab-based x-ray computed tomography
    Zwanenburg, E. A.
    Williams, M. A.
    Warnett, J. M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (01)
  • [4] Data Acquisition and Analysis at the X-ray Computed Tomography Beamline of SESAME
    Iori, Gianluca
    Matalgah, Salman
    Chrysostomou, Charalambos
    Al-Dalleh, Abdalla
    Alzu'bi, Mustafa
    2021 IEEE JORDAN INTERNATIONAL JOINT CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION TECHNOLOGY (JEEIT), 2021, : 134 - 139
  • [5] Development of high-speed micro computed tomography system based on carbon nanotube emitter x-ray source
    Kim, Wooseob
    Jung, Jaeik
    Rajpoot, Shalini
    Chung, Weon-Kuu
    Ahn, Jeungsun
    Lee, Byeong-No
    Ryu, Jehwang
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [6] Influence of Data Acquisition Algorithms on X-Ray Phase Contrast Imaging Computed Tomography
    Epstein, Collin J. C.
    Goodner, Ryan N.
    West, R. Derek
    Thompson, Kyle R.
    Dagel, Amber L.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2020, 3 (04):
  • [7] Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data
    Huang, Xuan
    Miao, Haichao
    Kim, Hyojin
    Townsend, Andrew
    Champley, Kyle
    Tringe, Joseph
    Pascucci, Valerio
    Bremer, Peer-Timo
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2025, 31 (04) : 2196 - 2210
  • [8] Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography
    Shearer, Tom
    Bradley, Robert S.
    Hidalgo-Bastida, L. Araida
    Sherratt, Michael J.
    Cartmell, Sarah H.
    JOURNAL OF CELL SCIENCE, 2016, 129 (13) : 2483 - 2492
  • [9] Segmentation of four-dimensional, X-ray computed tomography data
    Gibbs J.W.
    Voorhees P.W.
    Integrating Materials and Manufacturing Innovation, 2014, 3 (01) : 73 - 84
  • [10] Properties of preprocessed sinogram data in x-ray computed tomography
    Whiting, Bruce R.
    Massoumzadeh, Parinaz
    Earl, Orville A.
    O'Sullivan, Joseph A.
    Snyder, Donald L.
    Williamson, Jeffrey F.
    MEDICAL PHYSICS, 2006, 33 (09) : 3290 - 3303