Immediate effect of the MitraClip® procedure on mitral ring geometry in primary and secondary mitral regurgitation

被引:47
作者
Schmidt, Frank Patrick [1 ]
von Bardeleben, Ralph Stephan [1 ]
Nikolai, Philipp [1 ]
Jabs, Alexander [1 ]
Wunderlich, Nina [1 ]
Muenzel, Thomas [1 ]
Hink, Ulrich [1 ]
Warnholtz, Ascan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Med 2, D-55131 Mainz, Germany
关键词
Mitral valve geometry; MitraClip (R); Mitral regurgitation; 3D echocardiography; TO-EDGE REPAIR; INITIAL HUMAN-EXPERIENCE; VALVE REPAIR; ANNULOPLASTY; THERAPY; ECHOCARDIOGRAPHY; RECOMMENDATIONS; MANAGEMENT; SEVERITY; AREA;
D O I
10.1093/ehjci/jes293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Percutaneous treatment of mitral regurgitation (MR) has been shown to reduce MR severity and improve functional outcomes. Surgical treatment of MR usually includes mitral annulus reduction. The influence of the MitraClip (R) on annulus geometry is not clear. We wanted to investigate whether the procedure itself reduces annulus diameter and if there may be differences between secondary or functional (SMR) and primary (PMR) MR. Methods and results We retrospectively assessed 3D echocardiography (3D-TEE) data of 55 patients acquired during the procedure shortly before and after clip placement for changes in annulus diameter and area. Measurements were done with QLAB software. Patients were categorized as having either SMR (n = 41) or PMR (n = 14). In SMR, we were able to demonstrate a significant reduction in annulus area (mean Delta 1.30 +/- 1.44 cm(2); P < 0.001), anterior-posterior (AP)-diameter (mean Delta 0.28 +/- 0.32 cm; P < 0.001), tenting area (mean Delta 0.39 +/- 0.49 cm(2); P < 0.001). No significant change could be found for latero-medial (LM)-diameter. In contrast, we could not demonstrate significant changes in any of the parameters described above in patients with PMR. Conclusion Percutaneous treatment with the MitraClip (R) device can produce immediate reductions in mitral annulus size in SMR, probably supporting procedural success. It also reduces tenting, which may have prognostic implications. In contrast, these effects on mitral geometry cannot be demonstrated in PMR. Knowledge of this difference between SMR and PMR may be important to improve procedural strategies.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 23 条
[1]   Analysis of Procedural Effects of Percutaneous Edge-to-Edge Mitral Valve Repair by 2D and 3D Echocardiography [J].
Altiok, Ertunc ;
Hamada, Sandra ;
Brehmer, Kathrin ;
Kuhr, Kathrin ;
Reith, Sebastian ;
Becker, Michael ;
Schroeder, Joerg ;
Almalla, Mohammad ;
Lehmacher, Walter ;
Marx, Nikolaus ;
Hoffmann, Rainer .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) :748-755
[2]  
American College of Cardiology, 2006, J Am Coll Cardiol, V48, pe1, DOI 10.1016/j.jacc.2006.05.021
[3]   On the In Vivo Deformation of the Mitral Valve Anterior Leaflet: Effects of Annular Geometry and Referential Configuration [J].
Amini, Rouzbeh ;
Eckert, Chad E. ;
Koomalsingh, Kevin ;
McGarvey, Jeremy ;
Minakawa, Masahito ;
Gorman, Joseph H. ;
Gorman, Robert C. ;
Sacks, Michael S. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (07) :1455-1467
[4]   Correction of Mitral Regurgitation in Nonresponders to Cardiac Resynchronization Therapy by MitraClip Improves Symptoms and Promotes Reverse Remodeling [J].
Auricchio, Angelo ;
Schillinger, Wolfgang ;
Meyer, Sven ;
Maisano, Francesco ;
Hoffmann, Rainer ;
Ussia, Gian Paolo ;
Pedrazzini, Giovanni B. ;
van der Heyden, Jan ;
Fratini, Simona ;
Klersy, Catherine ;
Komtebedde, Jan ;
Franzen, Olaf .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2183-2189
[5]   Seven years' experience with suture annuloplasty for mitral valve repair [J].
Aybek, T ;
Risteski, P ;
Miskovic, A ;
Simon, A ;
Dogan, S ;
Abdel-Rahman, U ;
Moritz, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (01) :99-106
[6]   Mitral Annulus Dynamics Early after Valve Repair: Preliminary Observations of the Effect of Resectional Versus Non-Resectional Approaches [J].
Ben Zekry, Sagit ;
Lang, Roberto M. ;
Sugeng, Lissa ;
McCulloch, Marti L. ;
Weinert, Lynn ;
Raman, Jai ;
Little, Stephen H. ;
Xu, Jiaqiong ;
Lawrie, Gerald M. ;
Zoghbi, William A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (11) :1233-1242
[7]   Efficacy of the edge-to-edge repair in the setting of a dilated ventricle: An in vitro study [J].
Croft, Laura R. ;
Jimenez, Jorge H. ;
Gorman, Robert C. ;
Gorman, Joseph H., III ;
Yoganathan, Ajit P. .
ANNALS OF THORACIC SURGERY, 2007, 84 (05) :1578-1584
[8]   Percutaneous Repair or Surgery for Mitral Regurgitation [J].
Feldman, Ted ;
Foster, Elyse ;
Glower, Donald G. ;
Kar, Saibal ;
Rinaldi, Michael J. ;
Fail, Peter S. ;
Smalling, Richard W. ;
Siegel, Robert ;
Rose, Geoffrey A. ;
Engeron, Eric ;
Loghin, Catalin ;
Trento, Alfredo ;
Skipper, Eric R. ;
Fudge, Tommy ;
Letsou, George V. ;
Massaro, Joseph M. ;
Mauri, Laura .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (15) :1395-1406
[9]   Percutaneous Mitral Repair With the MitraClip System Safety and Midterm Durability in the Initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) Cohort [J].
Feldman, Ted ;
Kar, Saibal ;
Rinaldi, Michael ;
Fail, Peter ;
Hermiller, James ;
Smalling, Richard ;
Whitlow, Patrick L. ;
Gray, William ;
Low, Reginald ;
Herrmann, Howard C. ;
Lim, Scott ;
Foster, Elyse ;
Glower, Donald .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (08) :686-694
[10]   Quantitative assessment of severity of mitral regurgitation by serial echocardiography in a multicenter clinical trial of percutaneous mitral valve repair [J].
Foster, Elyse ;
Wasserman, Hal S. ;
Gray, William ;
Homma, Shunichi ;
Di Tullio, Marco R. ;
Rodriguez, Leonardo ;
Stewart, William J. ;
Whitlow, Patrick ;
Block, Peter ;
Martin, Randy ;
Merlino, John ;
Herrmann, Howard C. ;
Wiegers, Susan E. ;
Silvestry, Frank E. ;
Hamilton, Andrew ;
Zunamon, Alan ;
Kraybill, Kimberly ;
Gerber, Ivor L. ;
Weeks, Sarah G. ;
Zhang, Yan ;
Feldman, Ted .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (10) :1577-1583