Quantitative determination of capsaicin, a transient receptor potential channel vanilloid 1 agonist, by liquid chromatography quadrupole ion trap mass spectrometry: evaluation of in vitro metabolic stability

被引:22
|
作者
Beaudry, Francis [1 ]
Vachon, Pascal [1 ]
机构
[1] Univ Montreal, Fac Vet Med, Dept Vet Biomed, Mass Spectrometry & Med Chem Lab,Grp Rech Pharmac, St Hyacinthe, PQ J2S 2M2, Canada
关键词
capsaicin; bioanalysis; intrinsic clearance; microsomes; metabolism; liquid chromatography; electrospray; mass spectrometry; TRPV1; PHARMACOKINETICS; PREDICTION; EUGENOL;
D O I
10.1002/bmc.1107
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capsaicin is the most abundant pungent molecule present in red peppers and it is widely used for food flavoring, in pepper spray in self-defense devices and more recently in ointments for the relief of neuropathic pain. Capsaicin is a selective agonist of transient receptor potential channel, vanilloid subfamily member 1. A selective and sensitive quantitative method for the determination of capsaicin by LC-ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray quadrupole ion trap mass spectrometry. The chromatographic separation was achieved using a 100 x 2 mm C-18 Waters Symmetry column combined with a gradient mobile phase composed of acetonitrile and 0.1 % formic acid aqueous solution at a flow rate of 220 mu L/min. The mass spectrometer was operating in full-scan MS/MS mode using two-segment analysis. An analytical range of 10-5000 ng/mL was used in the calibration curve constructed in rat plasma. The interbatch precision and accuracy observed were 6.5,6.7,5.3 and 101.2,102.7,103.5% at 50, 500 and 5000 ng/mL, respectively. An in vitro metabolic stability study was performed in rat, dog and mouse liver microsomes and the novel analytical method was adapted and used to determine intrinsic clearance of capsaicin. Results suggest very rapid degradation with T-1/2 ranging from 2.3 to 4.1 min and high clearance values suggesting that drug bioavailability will be considerably reduced, consequently affecting drug response and efficacy. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 24 条
  • [21] Rapid, high performance method for the determination of vitamin K1, menaquinone-4 and vitamin K1 2,3-epoxide in human serum and plasma using liquid chromatography-hybrid quadrupole linear ion trap mass spectrometry
    Gentili, Alessandra
    Cafolla, Arturo
    Gasperi, Tecla
    Bellante, Simona
    Caretti, Fulvia
    Curini, Roberta
    Fernandez, Virginia Perez
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1338 : 102 - 110
  • [22] Systematic investigation on the chemical basis of anti-NAFLD Qushi Huayu Fang. Part 1: A study of metabolic profiles in vivo and in vitro by high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry
    Liu, Huan
    Sun, Zhaolin
    Tian, Xiaoting
    Feng, Qin
    Guo, Ziqiong
    Chen, Shuoji
    Yin, Hao
    Wang, Yangyang
    Xu, Zhou
    Xie, Like
    Hu, Pei
    Huang, Chenggang
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (05)
  • [23] Determination of 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) and its metabolite 2-hydroxyamino-PhIP by liquid chromatography/electrospray ionization-ion trap mass spectrometry
    Prabhu, S
    Lee, MJ
    Hu, WY
    Winnik, B
    Yang, I
    Buckley, B
    Hong, JY
    ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) : 306 - 313
  • [24] Determination of a peroxisome proliferator-activated receptor γ agonist, 1-(trans-methylimino-N-oxy)-6-(2-morpholinoethoxy-3-phenyl-1H-indene-2-carboxylic acid ethyl ester (KR-62980) in rat plasma by liquid chromatography-tandem mass spectrometry
    Kim, Min-Sun
    Song, Jin Sook
    Roh, Hyeongjin
    Park, Jong-Shik
    Ahn, Jin Hee
    Ahn, Sung-Hoon
    Bae, Myung Ae
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 121 - 126