Agreement between frequency-doubling technology perimetry and Heidelberg retinal tomography 3

被引:0
作者
Lee, Na Young [1 ,2 ]
Chung, Hye Jin [1 ,3 ]
Park, Chan Kee [1 ,4 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, Seoul 137040, South Korea
[2] Incheon St Marys Hosp, Inchon, South Korea
[3] Ueijungbu St Marys Hosp, Ueijungbu, South Korea
[4] Seoul St Marys Hosp, Seoul, South Korea
关键词
Frequency-doubling technology; Glaucoma probability score; Heidelberg retinal tomography 3; Pattern standard deviation; OPTIC-NERVE HEAD; WAVELENGTH AUTOMATED PERIMETRY; SCANNING LASER TOMOGRAPHY; OCULAR HYPERTENSION; GLAUCOMA; REPRODUCIBILITY; TOPOGRAPHY; DEFECTS; IMAGES; DAMAGE;
D O I
10.1007/s10384-012-0227-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare Heidelberg retinal tomography (HRT) 3 and frequency-doubling technology (FDT) perimetry for diagnosis of glaucoma. One eye of each of 117 patients was randomly chosen. The eyes were imaged by HRT3 and tested by FDT. The pattern standard deviation (PSD) and global glaucoma probability score (GPS) were selected as representative output, and sensitivity, specificity, positive predictive value, and negative predictive value determined for each. The agreement between the 2 diagnostic methods was analyzed. The sensitivity and specificity of HRT3 and FDT perimetry for PSD (65.4 and 62.7 %, respectively) and for GPS (69.2 and 62.7 %, respectively) were similar, as were the positive predictive values (PSD 40.5 %, GPS 41.9 %). However, the 2 methods had only slight diagnostic agreement (kappa = 0.112), and this was not significant (P = 0.281). FDT perimetry and HRT3 had no significant diagnostic agreement. Thus, the results from both examinations should be considered when determining diagnosis of glaucoma.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
[41]   Optic Disc Imaging with Spectral-Domain Optical Coherence Tomography Variability and Agreement Study with Heidelberg Retinal Tomograph [J].
Yang, Bingzhi ;
Ye, Cong ;
Yu, Marco ;
Liu, Shu ;
Lam, Dennis Shun Chiu ;
Leung, Christopher Kai-shun .
OPHTHALMOLOGY, 2012, 119 (09) :1852-1857
[42]   Prediction of visual field defects on standard automated perimetry by screening C-20-1 frequency doubling technology perimetry [J].
Kamantigue, MEG ;
Joson, PJ ;
Chen, PP .
JOURNAL OF GLAUCOMA, 2006, 15 (01) :35-39
[43]   Comparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss [J].
Saric, D ;
Mandic, Z ;
Ivekovic, R ;
Geber, MZ ;
Bencic, G ;
Tomic, Z ;
Grgic, D .
COLLEGIUM ANTROPOLOGICUM, 2005, 29 :111-113
[44]   Frequency-doubling technology (FDT) in patients with uncontrolled diabetes mellitus [J].
Shenoy, R. ;
Bialasiewicz, A. ;
Mcllvenny, S. ;
Bhargava, K. .
SPEKTRUM DER AUGENHEILKUNDE, 2006, 20 (03) :138-141
[45]   Correlation of Macular Ganglion Cell Complex Thickness With Frequency-doubling Technology Perimetry in Open-angle Glaucoma With Hemifield Defects [J].
Hayashi, Keiko ;
Araie, Makoto ;
Konno, Shinsuke ;
Tomidokoro, Atsuo .
JOURNAL OF GLAUCOMA, 2016, 25 (05) :426-432
[46]   Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology [J].
Takahashi, Genichiro ;
Demirel, Shaban ;
Johnson, Chris A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) :797-803
[47]   Frequency doubling technology perimetry with the Humphrey Matrix 30-2 test [J].
Brusini, P ;
Salvetat, ML ;
Zeppieri, M ;
Parisi, L .
JOURNAL OF GLAUCOMA, 2006, 15 (02) :77-83
[48]   The influence of learning effect on frequency doubling technology perimetry (Matrix) [J].
Contestabile, Maria Teresa ;
Perdicchi, Andrea ;
Amodeo, Stefano ;
Recupero, Vincenzo ;
Recupero Santi, Maria .
JOURNAL OF GLAUCOMA, 2007, 16 (03) :297-301
[49]   Measuring Visual Function in Age-Related Macular Degeneration with Frequency-Doubling (Matrix) Perimetry [J].
Anderson, Andrew John ;
Johnson, Chris A. ;
Werner, John S. .
OPTOMETRY AND VISION SCIENCE, 2011, 88 (07) :806-815
[50]   Multifocal and pattern-reversal visual evoked potentials vs. automated perimetry frequency-doubling technology matrix in optic neuritis [J].
Nebbioso, Marcella ;
Steigerwalt, Robert D. ;
Pecori-Giraldi, Jose ;
Vingolo, Enzo M. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (02) :59-64