Agreement between frequency-doubling technology perimetry and Heidelberg retinal tomography 3

被引:0
作者
Lee, Na Young [1 ,2 ]
Chung, Hye Jin [1 ,3 ]
Park, Chan Kee [1 ,4 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, Seoul 137040, South Korea
[2] Incheon St Marys Hosp, Inchon, South Korea
[3] Ueijungbu St Marys Hosp, Ueijungbu, South Korea
[4] Seoul St Marys Hosp, Seoul, South Korea
关键词
Frequency-doubling technology; Glaucoma probability score; Heidelberg retinal tomography 3; Pattern standard deviation; OPTIC-NERVE HEAD; WAVELENGTH AUTOMATED PERIMETRY; SCANNING LASER TOMOGRAPHY; OCULAR HYPERTENSION; GLAUCOMA; REPRODUCIBILITY; TOPOGRAPHY; DEFECTS; IMAGES; DAMAGE;
D O I
10.1007/s10384-012-0227-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare Heidelberg retinal tomography (HRT) 3 and frequency-doubling technology (FDT) perimetry for diagnosis of glaucoma. One eye of each of 117 patients was randomly chosen. The eyes were imaged by HRT3 and tested by FDT. The pattern standard deviation (PSD) and global glaucoma probability score (GPS) were selected as representative output, and sensitivity, specificity, positive predictive value, and negative predictive value determined for each. The agreement between the 2 diagnostic methods was analyzed. The sensitivity and specificity of HRT3 and FDT perimetry for PSD (65.4 and 62.7 %, respectively) and for GPS (69.2 and 62.7 %, respectively) were similar, as were the positive predictive values (PSD 40.5 %, GPS 41.9 %). However, the 2 methods had only slight diagnostic agreement (kappa = 0.112), and this was not significant (P = 0.281). FDT perimetry and HRT3 had no significant diagnostic agreement. Thus, the results from both examinations should be considered when determining diagnosis of glaucoma.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
  • [21] Changes in Frequency-Doubling Perimetry in Patients with Type I Diabetes prior to Retinopathy
    Pinilla, Isabel
    Ferreras, Antonio
    Idoipe, Miriam
    Sanchez-Cano, Ana I.
    Perez-Garcia, Diana
    Herrera, Laura X.
    Pinilla, Maria J.
    Abecia, Emilio
    [J]. BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [22] Detecting glaucoma with frequency-doubling technology perimetry - A comparison between N-30 and C-20 screening programs
    Fogagnolo, P
    Mazzolani, F
    Rossetti, L
    Orzalesi, N
    [J]. JOURNAL OF GLAUCOMA, 2005, 14 (06) : 485 - 491
  • [23] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [24] Detection of ocular disease by a vision-centre technician and the role of frequency-doubling technology perimetry in this setting
    Thomas, Ravi
    Naveen, Shoba
    Nirmalan, Praveen K.
    Parikh, Rajul
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) : 214 - 218
  • [25] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals
    de Tarso Ponte Pierre-Filho, Paulo
    Schimiti, Rui Barroso
    Cabral de Vasconcellos, Jose Paulo
    Costa, Vital Paulino
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03): : 345 - 350
  • [26] Effect of Refractive Correction on the Accuracy of Frequency-doubling Technology Matrix
    Contestabile, Maria T.
    Perdicchi, Andrea
    Amodeo, Stefano
    Paffetti, Lorenzo
    Iester, Michele
    Recupero, Santi M.
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (05) : 413 - 415
  • [27] Conventional perimetry, short-wavelength automated perimetry, frequency-doubling technology, and visual evoked potentials in the assessment of patients with multiple sclerosis
    Corallo, G
    Cicinelli, S
    Papadia, M
    Bandini, F
    Uccelli, A
    Calabria, G
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (06) : 730 - 738
  • [28] Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
    Hu, Rongrong
    Wang, Chenkun
    Racette, Lyne
    [J]. PLOS ONE, 2017, 12 (05):
  • [29] Evaluation of decision rules for frequency-doubling technology screening tests
    Gardiner, Stuart K.
    Anderson, Douglas R.
    Fingeret, Murray
    McSoley, John J.
    Johnson, Chris A.
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (07) : 432 - 437
  • [30] Frequency-doubling technology:: searching for the optimum diagnostic criteria for glaucoma
    Ferreras, Antonio
    Larrosa, Jose M.
    Polo, Vicente
    Pajarin, Ana B.
    Mayoral, Francesca
    Honrubia, Francisco M.
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01): : 73 - 79