Agreement between frequency-doubling technology perimetry and Heidelberg retinal tomography 3

被引:0
作者
Lee, Na Young [1 ,2 ]
Chung, Hye Jin [1 ,3 ]
Park, Chan Kee [1 ,4 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, Seoul 137040, South Korea
[2] Incheon St Marys Hosp, Inchon, South Korea
[3] Ueijungbu St Marys Hosp, Ueijungbu, South Korea
[4] Seoul St Marys Hosp, Seoul, South Korea
关键词
Frequency-doubling technology; Glaucoma probability score; Heidelberg retinal tomography 3; Pattern standard deviation; OPTIC-NERVE HEAD; WAVELENGTH AUTOMATED PERIMETRY; SCANNING LASER TOMOGRAPHY; OCULAR HYPERTENSION; GLAUCOMA; REPRODUCIBILITY; TOPOGRAPHY; DEFECTS; IMAGES; DAMAGE;
D O I
10.1007/s10384-012-0227-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare Heidelberg retinal tomography (HRT) 3 and frequency-doubling technology (FDT) perimetry for diagnosis of glaucoma. One eye of each of 117 patients was randomly chosen. The eyes were imaged by HRT3 and tested by FDT. The pattern standard deviation (PSD) and global glaucoma probability score (GPS) were selected as representative output, and sensitivity, specificity, positive predictive value, and negative predictive value determined for each. The agreement between the 2 diagnostic methods was analyzed. The sensitivity and specificity of HRT3 and FDT perimetry for PSD (65.4 and 62.7 %, respectively) and for GPS (69.2 and 62.7 %, respectively) were similar, as were the positive predictive values (PSD 40.5 %, GPS 41.9 %). However, the 2 methods had only slight diagnostic agreement (kappa = 0.112), and this was not significant (P = 0.281). FDT perimetry and HRT3 had no significant diagnostic agreement. Thus, the results from both examinations should be considered when determining diagnosis of glaucoma.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 50 条
[21]   Changes in Frequency-Doubling Perimetry in Patients with Type I Diabetes prior to Retinopathy [J].
Pinilla, Isabel ;
Ferreras, Antonio ;
Idoipe, Miriam ;
Sanchez-Cano, Ana I. ;
Perez-Garcia, Diana ;
Herrera, Laura X. ;
Pinilla, Maria J. ;
Abecia, Emilio .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[22]   Frequency Doubling Technology perimetry and standard automated perimetry in migraine [J].
Harle, DE ;
Evans, BJW .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) :233-239
[23]   Detecting glaucoma with frequency-doubling technology perimetry - A comparison between N-30 and C-20 screening programs [J].
Fogagnolo, P ;
Mazzolani, F ;
Rossetti, L ;
Orzalesi, N .
JOURNAL OF GLAUCOMA, 2005, 14 (06) :485-491
[24]   Detection of ocular disease by a vision-centre technician and the role of frequency-doubling technology perimetry in this setting [J].
Thomas, Ravi ;
Naveen, Shoba ;
Nirmalan, Praveen K. ;
Parikh, Rajul .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (02) :214-218
[25]   Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals [J].
de Tarso Ponte Pierre-Filho, Paulo ;
Schimiti, Rui Barroso ;
Cabral de Vasconcellos, Jose Paulo ;
Costa, Vital Paulino .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03) :345-350
[26]   Effect of Refractive Correction on the Accuracy of Frequency-doubling Technology Matrix [J].
Contestabile, Maria T. ;
Perdicchi, Andrea ;
Amodeo, Stefano ;
Paffetti, Lorenzo ;
Iester, Michele ;
Recupero, Santi M. .
JOURNAL OF GLAUCOMA, 2013, 22 (05) :413-415
[27]   Conventional perimetry, short-wavelength automated perimetry, frequency-doubling technology, and visual evoked potentials in the assessment of patients with multiple sclerosis [J].
Corallo, G ;
Cicinelli, S ;
Papadia, M ;
Bandini, F ;
Uccelli, A ;
Calabria, G .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (06) :730-738
[28]   Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes [J].
Hu, Rongrong ;
Wang, Chenkun ;
Racette, Lyne .
PLOS ONE, 2017, 12 (05)
[29]   Evaluation of decision rules for frequency-doubling technology screening tests [J].
Gardiner, Stuart K. ;
Anderson, Douglas R. ;
Fingeret, Murray ;
McSoley, John J. ;
Johnson, Chris A. .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (07) :432-437
[30]   Frequency-doubling technology:: searching for the optimum diagnostic criteria for glaucoma [J].
Ferreras, Antonio ;
Larrosa, Jose M. ;
Polo, Vicente ;
Pajarin, Ana B. ;
Mayoral, Francesca ;
Honrubia, Francisco M. .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01) :73-79