Objective: To analyze the mini-external fixation and percutaneous K-wire internal fixation for the treatment of Bennett fracture by using finite element analysis and to compare the biomechanical stability and postoperative impact of the two fixations on the fracture. Methods: Three-dimensional digital models of the first metacarpal bone, second metacarpal bone, and the trapezium were established using Mimics 10.01 software. A solid model and finite element models were created and analyzed using ANSYS 10.0. The same load of 100 N was exerted on both the mini-external fixator and the Kirschner (K)-wire internal fixator for the treatment of Bennett fracture. Finally, the none-line solution was analyzed, and displacement nephograms were obtained. Results: The displacement nephograms of the distal and proximal fragments of the fracture obtained using the mini-external and K-wire models were established. The X/Y/Z (SUM)component displacements of 15 nodes aligned with the articular surface fracture were obtained. The relative displacement of the distal and the proximal fragments of the fracture were calculated, and all digits of relative displacement were entered into SPSS 13.0 software. The difference between the X-component relative displacements was statistically significant. Moreover, the comparison of the Y-component, Z-component, and SUM-component relative displacements yielded statistical significance. The average relative displacement in the X-direction was 0.3214 mm in the K-wire model. Conclusion: Mini-external fixation is more effective than K-wire internal fixation for secure Bennett fracture stability. Both fixations have similar effects on postoperative traumatic arthritis and postoperative hand functions. Level of evidence: 1 Biomechanical studies. (C) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 50 条
  • [1] Finite element analysis of Kirschner wire fixation for lateral condyle fracture in children in the sagittal plane
    Bai, Huanan
    Lu, Qingda
    Liang, Xiaoju
    Wang, Xiaoming
    Yang, Yating
    Wang, Huan
    Wang, Jiaju
    Jie, Qiang
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [2] Three-dimensional finite element stress analysis on non-bridge external fixation to distal radius fracture
    Zhang, Wei
    Ju, Chaojie
    Hu, Yuanlong
    Yang, Ning
    Han, Yanlong
    Wang, Feng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 10910 - 10916
  • [3] Three-dimensional finite element analysis of a newly developed aliform internal fixation system for occipitocervical fusion
    Liao, Sui-Xiang
    Wang, Jian-Hua
    Zheng, Yong-Qiang
    Zheng, Guan
    Wei, Ge-Jing
    Xia, Hong
    Chen, Xiao-Hua
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) : 1392 - 1398
  • [4] Finite Element Analysis of Fracture Fixation
    Lewis, Gregory S.
    Mischler, Dominic
    Wee, Hwabok
    Reid, J. Spence
    Varga, Peter
    CURRENT OSTEOPOROSIS REPORTS, 2021, 19 (04) : 403 - 416
  • [5] Finite Element Analysis of Fracture Fixation
    Gregory S. Lewis
    Dominic Mischler
    Hwabok Wee
    J. Spence Reid
    Peter Varga
    Current Osteoporosis Reports, 2021, 19 : 403 - 416
  • [6] Mini-external fixation of two- and three-part proximal humerus fractures
    Ebraheim, Nabil A.
    Patil, Vishwas
    Husain, Adeel
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (04): : 437 - 442
  • [7] Biomechanical assessment of Kirschner wires integrated with a novel external fixation device for treatment of pediatric supracondylar humeral fracture: a finite element analysis
    Lu, Yu-Hsin
    Tai, Ching-Lung
    Lee, Wei-Chun
    Wang, Si-Yao
    Mao, Chi-Yu
    Yang, Wen-E.
    Chang, Chia-Hsieh
    Kao, Hsuan-Kai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [8] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Liao, Yijia
    Yan, Yiguo
    Kang, Yu
    Wang, Wenjun
    Song, Xizheng
    Peng, Wen
    Fu, Haibin
    Chen, Huarong
    Wang, Cheng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 469 - 478
  • [9] Three-dimensional finite element analysis: Anatomical splint fixation for Colles fractures
    Huang, Fei
    Tan, Rui
    Wang, Meng-Wei
    Hu, Liu-Chao
    Wang, Zhi
    Sun, Shi-Dong
    Huang, Jie-Wen
    Luo, Yi-Wen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2024, 27 (03)
  • [10] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Yijia Liao
    Yiguo Yan
    Yu Kang
    Wenjun Wang
    Xizheng Song
    Wen Peng
    Haibin Fu
    Huarong Chen
    Cheng Wang
    Journal of Medical and Biological Engineering, 2022, 42 : 469 - 478