Computer-assisted interpretation of flow cytometry data in hematology

被引:8
作者
Thews, O [1 ]
Thews, A [1 ]
Huber, C [1 ]
Vaupel, P [1 ]
机构
[1] UNIV MAINZ,DEPT HEMATOL,MED CLIN 3,D-55099 MAINZ,GERMANY
来源
CYTOMETRY | 1996年 / 23卷 / 02期
关键词
computer-assisted diagnosis; acute leukaemia; non-Hodgkin lymphoma; semantic network; artificial intelligence; expert system;
D O I
10.1002/cyto.990230202
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A computer program has been developed for computer-assisted diagnosis (including subclassification) of flow cytometry data of acute leukaemias and non-Hodgkin lymphomas by means of artificial intelligence. The knowledge base for the system has been formulated as semantic networks that describe physiological hematopoiesis as well as the pathological situation (e.g., aberrant antigen expression) of hematological disorders. The semantic networks reflect the hierarchy of cells and their occurrence in diseases, the normal and pathological antigen expression patterns of cells, cell maturation, and the frequency of cell populations in normal blood and bone marrow. Using these semantic networks, the diagnosis algorithm compares the characteristic antigen expression pattern of a disease with the actual findings in the blood or bone marrow sample, The algorithm can separate mixed populations by taking double staining findings into account. Finally, a diagnosis text is generated that describes all identified cell populations and the resulting diagnosis, The validation of the program showed a correct diagnosis (disease group and subclassification) in 97% of the cases (n = 633) with slight differences between the disease groups (e.g., B-NHL: 99%, B-cellALL:84%). (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:140 / 149
页数:10
相关论文
共 20 条
[1]   HIGH-PERFORMANCE FOR EXPERT SYSTEMS .1. ESCAPING FROM THE DEMONSTRATOR CLASS [J].
ALVEY, PL ;
MYERS, CD ;
GREAVES, MF .
MEDICAL INFORMATICS, 1987, 12 (02) :85-95
[2]  
ALVEY PL, 1987, LEUKEMIA, V1, P527
[3]   HIGH-PERFORMANCE FOR EXPERT SYSTEMS .2. A SYSTEM FOR LEUKEMIA DIAGNOSIS [J].
ALVEY, PL ;
PRESTON, NJ ;
GREAVES, MF .
MEDICAL INFORMATICS, 1987, 12 (02) :97-114
[4]  
[Anonymous], [No title captured]
[5]   STATISTICAL EVALUATION OF CELL KINETIC DATA FROM DNA FLOW-CYTOMETRY (FCM) BY THE EM ALGORITHM [J].
BALDETORP, B ;
DALBERG, M ;
HOLST, U ;
LINDGREN, G .
CYTOMETRY, 1989, 10 (06) :695-705
[6]   NEURAL-NETWORK ANALYSIS OF FLOW CYTOMETRIC DATA FOR 40 MARINE-PHYTOPLANKTON SPECIES [J].
BODDY, L ;
MORRIS, CW ;
WILKINS, MF ;
TARRAN, GA ;
BURKILL, PH .
CYTOMETRY, 1994, 15 (04) :283-293
[7]   A KNOWLEDGE-BASED SYSTEM FOR THE INTERPRETATION OF FLOW-CYTOMETRY DATA IN LEUKEMIAS AND LYMPHOMAS [J].
DIAMOND, LW ;
NGUYEN, DT ;
ANDREEFF, M ;
MAIESE, RL ;
BRAYLAN, RC .
CYTOMETRY, 1994, 17 (03) :266-273
[8]  
FOON KA, 1986, BLOOD, V68, P1
[9]   USE OF A NEURAL NET COMPUTER-SYSTEM FOR ANALYSIS OF FLOW CYTOMETRIC DATA OF PHYTOPLANKTON POPULATIONS [J].
FRANKEL, DS ;
OLSON, RJ ;
FRANKEL, SL ;
CHISHOLM, SW .
CYTOMETRY, 1989, 10 (05) :540-550
[10]  
HOMBURGER HA, 1989, ARCH PATHOL LAB MED, V113, P667