Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study

被引:4
作者
Halama, Dirk [1 ]
Merkel, Helena [2 ]
Werdehausen, Robert [3 ]
Gaber, Khaled [4 ]
Schob, Stefan [5 ]
Quaschling, Ulf [6 ]
Ziganshyna, Svitlana [7 ]
Hoffmann, Karl-Titus [1 ]
Lindner, Dirk [4 ]
Richter, Cindy [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Oral & Maxillofacial Surg, D-04103 Leipzig, Germany
[2] Univ Leipzig, Med Ctr, Dept Neuroradiol, D-04103 Leipzig, Germany
[3] Univ Leipzig, Med Ctr, Dept Anesthesiol & Intens Care Med, D-04103 Leipzig, Germany
[4] Univ Leipzig, Med Ctr, Dept Neurosurg, D-04103 Leipzig, Germany
[5] Halle Univ Hosp, Dept Radiol, D-06120 Halle, Germany
[6] Kantonsspital Baselland, Dept Radiol, CH-4410 Liestal, Switzerland
[7] Univ Leipzig, Med Ctr, Transplant Coordinator Unit, D-04103 Leipzig, Germany
关键词
vessel diameter; reference value; effect size; nomogram; morphological variation; digital subtraction angiography; ANEURYSMAL SUBARACHNOID HEMORRHAGE; ADULT LIFE; BLOOD-FLOW; VASOSPASM; WILLIS; CIRCLE; SEX; AGE; EPIDEMIOLOGY; BIFURCATION;
D O I
10.3390/diagnostics12102471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A threshold-based classification of cerebral vasospasm needs reference values for intracranial vessel diameters on digital subtraction angiography (DSA). We aimed to generate adjusted reference values for this purpose by retrospectively analyzing angiograms and potential influencing factors on vessel diameters. Angiograms of the anterior circulation were evaluated in 278 patients aged 18-81 years. The vessel diameters of 453 angiograms (175 bilateral) were gathered from nine defined measuring sites. The effect sizes of physical characteristics (i.e., body weight and height, body mass index, gender, age, and cranial side) and anatomical variations were calculated with MANOVA. Segments bearing aneurysms were excluded for the calculation of reference values. Adjusted vessel diameters were calculated via linear regression analysis of the vessel diameter data. Vessel diameters increased with age and body height. Male and right-sided vessels were larger in diameter. Of the anatomical variations, only the hypoplastic/aplastic A1 segment had a significant influence (p < 0.05) on values of the anterior cerebral artery and the internal carotid artery with a small effect size (|omega(2)| > 0.01) being excluded from the reference values. We provide gender-, age-, and side-adjusted reference values and nomograms of arterial vessel diameters in the anterior circulation.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Can angiogenesis be reliably determined on digital subtraction angiography in cerebral arteriovenous malformations?
    Das, Suparna
    Raffalli-Ebezant, Helen
    Kasher, Paul R.
    Parry-Jones, Adrian
    Patel, Hiren C.
    BRITISH JOURNAL OF NEUROSURGERY, 2024,
  • [42] Territorial Arterial Spin Labeling in the Assessment of Collateral Circulation Comparison With Digital Subtraction Angiography
    Chng, Soke Miang
    Petersen, Esben Thade
    Zimine, Ivan
    Sitoh, Yih-Yian
    Lim, C. C. Tchoyoson
    Golay, Xavier
    STROKE, 2008, 39 (12) : 3248 - 3254
  • [43] Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis
    Chappell, ET
    Moure, FC
    Good, MC
    NEUROSURGERY, 2003, 52 (03) : 624 - 630
  • [44] Usefulness of CT angiography for characterizing cerebral arteriovenous malformations presenting as hemorrhage: comparison with digital subtraction angiography
    Zwanzger, C.
    Lopez-Rueda, A.
    Campodonico, D.
    Rosati, S.
    Blasco, J.
    San Roman, L.
    Macho, J.
    RADIOLOGIA, 2020, 62 (05): : 392 - 399
  • [45] The measurement of internal carotid artery stenosis: Comparison of duplex with digital subtraction angiography
    Padayachee, TS
    Cox, TCS
    Modaresi, KB
    Colchester, ACF
    Taylor, PR
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (02) : 180 - 185
  • [46] Towards quantitative digital subtraction perfusion angiography: An animal study
    Su, Ruisheng
    van der Sluijs, P. Matthijs
    Bobi, Joaquim
    Taha, Aladdin
    van Beusekom, Heleen M. M.
    van der Lugt, Aad
    Niessen, Wiro J.
    Ruijters, Danny
    van Walsum, Theo
    MEDICAL PHYSICS, 2023, 50 (07) : 4055 - 4066
  • [47] Design of a high-resolution segmentation network for digital subtraction angiography of cerebral vessels
    Cui Y.
    Fu R.
    Zhu J.
    Gao S.
    Chen L.
    Zhang G.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2024, 45 (04): : 786 - 793
  • [48] ERNet: Edge Regularization Network for Cerebral Vessel Segmentation in Digital Subtraction Angiography Images
    Xu, Weijin
    Yang, Huihua
    Shi, Yinghuan
    Tan, Tao
    Liu, Wentao
    Pan, Xipeng
    Deng, Yiming
    Gao, Feng
    Su, Ruisheng
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (03) : 1472 - 1483
  • [49] Analysis of Radiation Doses and Dose Reduction Strategies During Cerebral Digital Subtraction Angiography
    Yi, Ho Jun
    Sung, Jae Hoon
    Lee, Dong Hoon
    Kim, Sang Wook
    Lee, Sang Won
    WORLD NEUROSURGERY, 2017, 100 : 216 - 223
  • [50] Surgical anatomy of the cerebral arteries in patients with subarachnoid hemorrhage: comparison of computerized tomography angiography and digital subtraction angiography
    Velthuis, BK
    van Leeuwen, MS
    Witkamp, TD
    Ramos, LMP
    van der Sprenkel, JWB
    Rinkel, GJE
    JOURNAL OF NEUROSURGERY, 2001, 95 (02) : 206 - 212