Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study

被引:4
作者
Halama, Dirk [1 ]
Merkel, Helena [2 ]
Werdehausen, Robert [3 ]
Gaber, Khaled [4 ]
Schob, Stefan [5 ]
Quaschling, Ulf [6 ]
Ziganshyna, Svitlana [7 ]
Hoffmann, Karl-Titus [1 ]
Lindner, Dirk [4 ]
Richter, Cindy [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Oral & Maxillofacial Surg, D-04103 Leipzig, Germany
[2] Univ Leipzig, Med Ctr, Dept Neuroradiol, D-04103 Leipzig, Germany
[3] Univ Leipzig, Med Ctr, Dept Anesthesiol & Intens Care Med, D-04103 Leipzig, Germany
[4] Univ Leipzig, Med Ctr, Dept Neurosurg, D-04103 Leipzig, Germany
[5] Halle Univ Hosp, Dept Radiol, D-06120 Halle, Germany
[6] Kantonsspital Baselland, Dept Radiol, CH-4410 Liestal, Switzerland
[7] Univ Leipzig, Med Ctr, Transplant Coordinator Unit, D-04103 Leipzig, Germany
关键词
vessel diameter; reference value; effect size; nomogram; morphological variation; digital subtraction angiography; ANEURYSMAL SUBARACHNOID HEMORRHAGE; ADULT LIFE; BLOOD-FLOW; VASOSPASM; WILLIS; CIRCLE; SEX; AGE; EPIDEMIOLOGY; BIFURCATION;
D O I
10.3390/diagnostics12102471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A threshold-based classification of cerebral vasospasm needs reference values for intracranial vessel diameters on digital subtraction angiography (DSA). We aimed to generate adjusted reference values for this purpose by retrospectively analyzing angiograms and potential influencing factors on vessel diameters. Angiograms of the anterior circulation were evaluated in 278 patients aged 18-81 years. The vessel diameters of 453 angiograms (175 bilateral) were gathered from nine defined measuring sites. The effect sizes of physical characteristics (i.e., body weight and height, body mass index, gender, age, and cranial side) and anatomical variations were calculated with MANOVA. Segments bearing aneurysms were excluded for the calculation of reference values. Adjusted vessel diameters were calculated via linear regression analysis of the vessel diameter data. Vessel diameters increased with age and body height. Male and right-sided vessels were larger in diameter. Of the anatomical variations, only the hypoplastic/aplastic A1 segment had a significant influence (p < 0.05) on values of the anterior cerebral artery and the internal carotid artery with a small effect size (|omega(2)| > 0.01) being excluded from the reference values. We provide gender-, age-, and side-adjusted reference values and nomograms of arterial vessel diameters in the anterior circulation.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Evaluation of the Vertebral Artery by 3D Digital Subtraction Angiography
    Tetiker, Hasan
    Cimen, Mehmet
    Kosar, Mehmet Ilkay
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2014, 32 (03): : 798 - 802
  • [32] Digital Subtraction Angiography of the Superior Mesenteric Artery: Identifying Arterial Branches
    Turmezei, T. D.
    Cockburn, J. F.
    CLINICAL ANATOMY, 2009, 22 (06) : 777 - 779
  • [33] Virtual surgical planning for superficial temporal artery to middle cerebral artery bypass using three-dimensional digital subtraction angiography
    Nakagawa, Ichiro
    Kurokawa, Shinichiro
    Tanisaka, Megumi
    Kimura, Ryota
    Nakase, Hiroyuki
    ACTA NEUROCHIRURGICA, 2010, 152 (09) : 1535 - 1541
  • [34] Virtual surgical planning for superficial temporal artery to middle cerebral artery bypass using three-dimensional digital subtraction angiography
    Ichiro Nakagawa
    Shinichiro Kurokawa
    Megumi Tanisaka
    Ryota Kimura
    Hiroyuki Nakase
    Acta Neurochirurgica, 2010, 152 : 1535 - 1541
  • [35] Prospective analysis of complications of catheter cerebral angiography in the digital subtraction angiography and magnetic resonance era
    Komiyama, M
    Yamanaka, K
    Nishikawa, M
    Izumi, T
    NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 (09): : 534 - 539
  • [36] Middle cerebral artery anatomical variations and aneurysms: a retrospective study based on computed tomography angiography findings
    Brzegowy, P.
    Polak, J.
    Wnuk, J.
    Lasocha, B.
    Walocha, J.
    Popiela, T. J.
    FOLIA MORPHOLOGICA, 2018, 77 (03) : 434 - 440
  • [37] Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
    Ding, Juan
    Sun, Gang
    Lu, Yang
    Yu, Bing-bing
    Li, Min
    Li, Li
    Li, Guo-ying
    Peng, Zhao-hui
    Zhang, Xu-Ping
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 667 - 673
  • [38] Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography: Patient and phantom study
    Song, Yunsun
    Kim, Youngeun
    Han, Seongsik
    Kim, Tae Il
    Choi, Joon Ho
    Maeng, Jun Young
    Choi, Youngrak
    Lee, Deok Hee
    JOURNAL OF NEURORADIOLOGY, 2019, 46 (06) : 345 - 350
  • [39] The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage
    Saboori, Masih
    Hekmatnia, Ali
    Ghazavi, Amirhossein
    Basiratnia, Reza
    Omidifar, Navid
    Hekmatnia, Farzaneh
    Isfahani, Homayoon Naji
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2011, 16 (08): : 1020 - 1025
  • [40] Standardized Classification of Cerebral Vasospasm after Subarachnoid Hemorrhage by Digital Subtraction Angiography
    Merkel, Helena
    Lindner, Dirk
    Gaber, Khaled
    Ziganshyna, Svitlana
    Jentzsch, Jennifer
    Mucha, Simone
    Gerhards, Thilo
    Sari, Sabine
    Stock, Annika
    Vothel, Felicitas
    Falter, Lea
    Quaeschling, Ulf
    Hoffmann, Karl-Titus
    Meixensberger, Juergen
    Halama, Dirk
    Richter, Cindy
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (07)