Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study

被引:4
|
作者
Halama, Dirk [1 ]
Merkel, Helena [2 ]
Werdehausen, Robert [3 ]
Gaber, Khaled [4 ]
Schob, Stefan [5 ]
Quaschling, Ulf [6 ]
Ziganshyna, Svitlana [7 ]
Hoffmann, Karl-Titus [1 ]
Lindner, Dirk [4 ]
Richter, Cindy [1 ]
机构
[1] Univ Leipzig, Med Ctr, Dept Oral & Maxillofacial Surg, D-04103 Leipzig, Germany
[2] Univ Leipzig, Med Ctr, Dept Neuroradiol, D-04103 Leipzig, Germany
[3] Univ Leipzig, Med Ctr, Dept Anesthesiol & Intens Care Med, D-04103 Leipzig, Germany
[4] Univ Leipzig, Med Ctr, Dept Neurosurg, D-04103 Leipzig, Germany
[5] Halle Univ Hosp, Dept Radiol, D-06120 Halle, Germany
[6] Kantonsspital Baselland, Dept Radiol, CH-4410 Liestal, Switzerland
[7] Univ Leipzig, Med Ctr, Transplant Coordinator Unit, D-04103 Leipzig, Germany
关键词
vessel diameter; reference value; effect size; nomogram; morphological variation; digital subtraction angiography; ANEURYSMAL SUBARACHNOID HEMORRHAGE; ADULT LIFE; BLOOD-FLOW; VASOSPASM; WILLIS; CIRCLE; SEX; AGE; EPIDEMIOLOGY; BIFURCATION;
D O I
10.3390/diagnostics12102471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A threshold-based classification of cerebral vasospasm needs reference values for intracranial vessel diameters on digital subtraction angiography (DSA). We aimed to generate adjusted reference values for this purpose by retrospectively analyzing angiograms and potential influencing factors on vessel diameters. Angiograms of the anterior circulation were evaluated in 278 patients aged 18-81 years. The vessel diameters of 453 angiograms (175 bilateral) were gathered from nine defined measuring sites. The effect sizes of physical characteristics (i.e., body weight and height, body mass index, gender, age, and cranial side) and anatomical variations were calculated with MANOVA. Segments bearing aneurysms were excluded for the calculation of reference values. Adjusted vessel diameters were calculated via linear regression analysis of the vessel diameter data. Vessel diameters increased with age and body height. Male and right-sided vessels were larger in diameter. Of the anatomical variations, only the hypoplastic/aplastic A1 segment had a significant influence (p < 0.05) on values of the anterior cerebral artery and the internal carotid artery with a small effect size (|omega(2)| > 0.01) being excluded from the reference values. We provide gender-, age-, and side-adjusted reference values and nomograms of arterial vessel diameters in the anterior circulation.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Middle rectal artery: myth or reality? Retrospective study with CT angiography and digital subtraction angiography
    Tiago Bilhim
    José A. Pereira
    Hugo Rio Tinto
    Lúcia Fernandes
    Marisa Duarte
    João E. O’Neill
    João M. Pisco
    Surgical and Radiologic Anatomy, 2013, 35 : 517 - 522
  • [2] Middle rectal artery: myth or reality? Retrospective study with CT angiography and digital subtraction angiography
    Bilhim, Tiago
    Pereira, Jose A.
    Tinto, Hugo Rio
    Fernandes, Lucia
    Duarte, Marisa
    O'Neill, Joao E.
    Pisco, Joao M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2013, 35 (06) : 517 - 522
  • [3] Propofol/Remifentanil Anesthesia Might Not Alter the Middle Cerebral Artery Diameter by Digital Subtraction Angiography
    Arrigoni-Marocco, Stefano
    Engrand, Nicolas
    Civelli, Vittorio
    Mateo, Joaquim
    Labeyrie, Marc-Antoine
    Saint-Maurice, Jean-Pierre
    Mebazaa, Alexandre
    Gayat, Etienne
    Houdart, Emmanuel
    Vallee, Fabrice
    NEUROCRITICAL CARE, 2019, 31 (02) : 338 - 345
  • [4] Reevaluating the Transcranial Doppler Criteria for Estimation of Anterior Circulation Artery Stenosis Transcranial Doppler Sonography Versus Digital Subtraction Angiography
    Fu, Xian
    Yin, Jianrui
    Wong, Ka Sing
    Gao, Cong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (08) : 1187 - 1191
  • [5] Analysis of Anterior Circulation Diameters According to Age, Gender, and Side Using Computed Tomography Angiography
    Yesilyurt, Mustafa
    Sade, Recep
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2023, 72 (04) : 283 - 289
  • [6] Inner diameters of the normal carotid arteries measured using three-dimensional digital subtraction catheter angiography: a retrospective analysis
    Tan, Qingjing
    Qin, Chao
    Yang, Junwei
    Wang, Tianbao
    Lin, Haohai
    Lin, Cuiting
    Chen, Xiangren
    BMC NEUROLOGY, 2021, 21 (01)
  • [7] Cerebral Digital Subtraction Angiography in Acute Intracranial Hemorrhage: Considerations in Critically Ill Children
    Harrar, D. B.
    Sun, L. R.
    Goss, M.
    Pearl, M. S.
    JOURNAL OF CHILD NEUROLOGY, 2022, 37 (8-9) : 693 - 701
  • [8] Anterior Cerebral Artery and Anterior Communicating Artery Variations: Assessment with Magnetic Resonance Angiography
    Yokus, Adem
    Toprak, Nursen
    Gunduz, Ali Mahir
    Akdeniz, Huseyin
    Akdemir, Zulkuf
    Dundar, Ilyas
    Arslan, Harun
    WORLD NEUROSURGERY, 2021, 155 : E203 - E209
  • [9] Parametric Digital Subtraction Angiography Imaging for the Objective Grading of Collateral Flow in Acute Middle Cerebral Artery Occlusion
    Wen, Wan-ling
    Fang, Yi-bin
    Yang, Peng-fei
    Zhang, Yong-wei
    Wu, Yi-na
    Shen, Hui
    Ge, Jia-jia
    Xu, Yi
    Hong, Bo
    Huang, Qing-hai
    Liu, Jian-min
    WORLD NEUROSURGERY, 2016, 88 : 119 - 125
  • [10] Automated image registration of cerebral digital subtraction angiography
    Hellebrekers, Vincent J. W.
    van Walsum, Theo
    Smal, Ihor
    Cornelissen, Sandra A. P.
    van Zwam, Wim H.
    Van der Lugt, Aad
    Van der Sluijs, Matthijs
    Su, Ruisheng
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (01) : 147 - 150