The ability of the Contact Lens Dry Eye Questionnaire (CLDEQ)-8 to detect ocular surface alterations in contact lens wearers

被引:10
|
作者
Lopez-de la Rosa, Alberto [1 ,2 ]
Arroyo-del Arroyo, Cristina [1 ,2 ]
Enriquez-de-Salamanca, Amalia [1 ,3 ]
Pinto-Fraga, Jose [1 ,3 ]
Lopez-Miguel, Alberto [1 ,4 ]
Gonzalez-Garcia, Maria J. [1 ,2 ,3 ]
机构
[1] Univ Valladolid, Inst Appl Ophthalmobiol IOBA, Valladolid, Spain
[2] Univ Valladolid, Dept Theoret Phys Atom & Opt, Valladolid, Spain
[3] Networking Res Ctr Bioengn Biomat & Nanomed CIBER, Valladolid, Spain
[4] Inst Salud Carlos III, Redes Temat Invest Cooperat Salud Oftared, Madrid, Spain
关键词
Clinical sign; Osmolarity; Contact lens; Discomfort; CLDEQ; TFOS INTERNATIONAL WORKSHOP; TEAR FILM; DISCOMFORT REPORT; EXTENDED WEAR; HYDROGEL; CLASSIFICATION; CORNEAL; DEFINITION; SYMPTOMS; CLDEQ-8;
D O I
10.1016/j.clae.2018.11.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study whether some ocular surface alterations could be associated with contact lens (CL) wearers suffering from CL discomfort (CLD) detected using the Contact Lens Dry Eye Questionnaire (CLDEQ)-8. Methods: Forty-one soft CL wearers further classified into symptomatic CL wearers (SCLW) and asymptomatic CL wearers (ACLW) by the CLDEQ-8, and 20 non CL wearers (NCLW) were included. Tear osmolarity, slit-lamp biomicroscopy findings, tear film break-up time, corneal and conjunctival staining, and Schirmer test were performed 24 h after CL removal. Data were compared among groups using the analysis of variance and the Student t-test or the Kruskal-Wallis H and the Mann-Whitney U tests, applying the Bonferroni correction. Correlations between the CLDEQ-8 and the clinical signs were performed using the Spearman correlation coefficient. Results: Twenty-four SCLW, 17 ACLW and 20 NCLW were recruited. There were significant differences among groups for tear osmolarity (p < 0.001), limbal hyperaemia (p = 0.014), and tarsal hyperaemia (p = 0.031). Pairwise comparisons revealed that SCLW and ACLW had higher tear osmolarity (p < 0.003, both comparisons) and limbal hyperaemia (p = 0.027 and p = 0.048, respectively) than NCLW. Moreover, SCLW had higher tarsal hyperaemia (p = 0.030) than NCLW. No significant correlations were found (p > 0.05). Conclusion: The CLDEQ-8 was ineffective to detect clinical alterations between SCLW and ACLW; therefore, the use of questionnaires alone remains being the best approach to detect CLD. The role of the tarsal conjunctiva in the development of CLD should be analyzed in future studies.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 50 条
  • [31] The effect of rebamipide ophthalmic suspension on ocular surface mucins in soft contact lens wearers
    Shigeyasu, Chika
    Yamada, Masakazu
    Akune, Yoko
    Fukui, Masaki
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (04) : 357 - 361
  • [32] DRY EYE IN CONTACT LENS WEARERS AS A GROWING PUBLIC HEALTH PROBLEM
    Pili, Kristijan
    Kastelan, Snjezana
    Karabatic, Mirela
    Kasun, Boris
    Culig, Borna
    PSYCHIATRIA DANUBINA, 2014, 26 : 528 - 532
  • [33] Not All Dry Eye in Contact Lens Wear Is Contact Lens-Induced
    Molina, Karen
    Graham, Andrew D.
    Yeh, Thao
    Lerma, Mariel
    Li, Wing
    Tse, Vivien
    Lin, Meng C.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (04): : 214 - 222
  • [34] Intolerant contact lens wearers exhibit ocular surface impairment despite 3 months wear discontinuation
    Giannaccare, Giuseppe
    Blalock, William
    Fresina, Michela
    Vagge, Aldo
    Versura, Piera
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (09) : 1825 - 1831
  • [35] Presence of Acanthamoeba in the ocular surface in a Spanish population of contact lens wearers
    Javier Rodríguez-Martín
    Pedro Rocha-Cabrera
    María Reyes-Batlle
    Atteneri López-Arencibia
    Ines Sifaoui
    Aitor Rizo-Liendo
    Carlos J. Bethencourt-Estrella
    José E. Piñero
    Jacob Lorenzo-Morales
    Acta Parasitologica, 2018, 63 : 393 - 396
  • [36] Presence of Acanthamoeba in the ocular surface in a Spanish population of contact lens wearers
    Rodriguez-Martin, Javier
    Rocha-Cabrera, Pedro
    Reyes-Batlle, Maria
    Lopez-Arencibia, Atteneri
    Sifaoui, Ines
    Rizo-Liendo, Aitor
    Bethencourt-Estrella, Carlos J.
    Pinero, Jose E.
    Lorenzo-Morales, Jacob
    ACTA PARASITOLOGICA, 2018, 63 (02) : 393 - 396
  • [37] Objective Metrics of Ocular Surface Disease in Contact Lens Wearers: Meibography
    Qazi Y.
    Hamrah P.
    Current Ophthalmology Reports, 2015, 3 (2) : 122 - 131
  • [38] Ocular thermography and clinical measurements in symptomatic and asymptomatic soft contact lens wearers
    Moghadas, Maryam
    Nosch, Daniela S.
    Kaser, Emanuele
    Klostermeier, Jennifer
    Santer, Verena
    Demian, Paul
    Bertolini, Giovanni
    Lamrani, Mouad
    OPTOMETRY AND VISION SCIENCE, 2024, 101 (09) : 595 - 602
  • [39] Ocular Surface Comfort During the Day Assessed by Instant Reporting in Different Types of Contact and Non-Contact Lens Wearers
    Santodomingo-Rubido, Jacinto
    Barrado-Navascues, Eva
    Rubido-Crespo, Maria-Jose
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (02): : 96 - 100
  • [40] Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers
    Chen, Qi
    Jiang, Hong
    Wang, Jianhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 99 - 109