Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator

被引:40
作者
Henningsson, Markus [1 ]
Smink, Jouke [2 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Best, Netherlands
[3] Kings Coll London, Wellcome Trust, London WC2R 2LS, England
[4] Kings Coll London, EPSRC Med Engn Ctr, London WC2R 2LS, England
[5] Kings Coll London, BHF Ctr Excellence, London WC2R 2LS, England
[6] Kings Coll London, NIHR Biomed Res Ctr, London WC2R 2LS, England
基金
英国工程与自然科学研究理事会;
关键词
respiratory motion correction; coronary MR angiography; 2D navigator; prospective motion correction; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY MOTION; HEART; RECONSTRUCTION; COMPENSATION; ALGORITHM;
D O I
10.1002/mrm.24280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion remains the major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography. Motion correction in coronary magnetic resonance angiography is typically performed with a diaphragmatic 1D navigator (1Dnav) assuming a constant linear relationship between diaphragmatic and cardiac respiratory motion. In this work, a novel 2D navigator (2Dnav) is proposed, which prospectively corrects for translational motion in foothead and leftright direction. First, 1Dnav- and 2Dnav-based motion correction are compared in 2D real time imaging experiments, by evaluating the residual respiratory motion in 10 healthy subjects as well as in a moving vessel phantom. Subsequently, 1Dnav and 2Dnav corrected high-resolution 3D coronary MR angiograms were acquired, and both objective and subjective image quality were assessed. For a gating window of 10 mm, 1Dnav and 2Dnav performed equally well; however, without any respiratory gating, the 1Dnav had a lower visual score for all coronary arteries compared with 10 mm gating, whereas the 2Dnav without gating performed similar to 1Dnav with 10 mm gating. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 29 条
[1]   Characterizing coronary motion and its effect on MR coronary angiography - Initial experience [J].
Al-Kwifi, Osama ;
Stainsby, Jeffrey ;
Foltz, Warren D. ;
Sussman, Marshall S. ;
Huang, Yuexi ;
Wright, Graham A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :842-850
[2]   Relationship between motion of coronary arteries and diaphragm during free breathing: Lessons from real-time MR imaging [J].
Danias, PG ;
Stuber, M ;
Botnar, RM ;
Kissinger, KV ;
Edelman, RR ;
Manning, WJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1061-1065
[3]   Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography [J].
Dewan, Maneesh ;
Hager, Gregory D. ;
Lorenz, Christine H. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :604-615
[4]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[5]   Analysis of residual coronary artery motion for breath hold and navigator approaches using real-time coronary MRI [J].
Fischer, RW ;
Botnar, RM ;
Nehrke, K ;
Boesiger, P ;
Manning, WJ ;
Peters, DC .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :612-618
[6]  
Gurney PT, 2007, P 15 ANN M ISMRM BER
[7]   Cartesian SENSE and k-t SENSE reconstruction using commodity graphics hardware [J].
Hansen, Michael S. ;
Atkinson, David ;
Sorensen, Thomas S. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :463-468
[8]   Whole-heart coronary MR angiography with 2D self-navigated image reconstruction [J].
Henningsson, Markus ;
Koken, Peter ;
Stehning, Christian ;
Razavi, Reza ;
Prieto, Claudia ;
Botnar, Rene M. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) :437-445
[9]   Low-cost MR-compatible moving heart phantom [J].
Huber, ME ;
Stuber, M ;
Botnar, RM ;
Boesiger, P ;
Manning, WJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (03) :181-187
[10]   Improved bulk myocardial motion suppression for navigator-gated coronary magnetic resonance imaging [J].
Jahnke, Cosima ;
Nehrke, Kay ;
Paetsch, Ingo ;
Schnackenburg, Bernhard ;
Gebker, Rolf ;
Fleck, Eckart ;
Nagel, Eike .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) :780-786