Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors

被引:26
|
作者
Fantozzi, Silvia [1 ]
Giovanardi, Andrea [2 ]
Borra, Davide [1 ]
Gatta, Giorgio [3 ]
机构
[1] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Bologna, Italy
[2] Univ Bologna, Sch Pharm Biotechnol & Sport Sci, Bologna, Italy
[3] Univ Bologna, Dept Life Qual Studies, Bologna, Italy
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
WALKING SPEED; BIOMECHANICAL CHARACTERISTICS; REACTION FORCES; LAND;
D O I
10.1371/journal.pone.0138105
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Walking is one of the fundamental motor tasks executed during aquatic therapy. Previous kinematics analyses conducted using waterproofed video cameras were limited to the sagittal plane and to only one or two consecutive steps. Furthermore, the set-up and post-processing are time-consuming and thus do not allow a prompt assessment of the correct execution of the movements during the aquatic session therapy. The aim of the present study was to estimate the 3D joint kinematics of the lower limbs and thorax-pelvis joints in sagittal and frontal planes during underwater walking using wearable inertial and magnetic sensors. Eleven healthy adults were measured during walking both in shallow water and in dry-land conditions. Eight wearable inertial and magnetic sensors were inserted in waterproofed boxes and fixed to the body segments by means of elastic modular bands. A validated protocol (Outwalk) was used. Gait cycles were automatically segmented and selected if relevant intraclass correlation coefficients values were higher than 0.75. A total of 704 gait cycles for the lower limb joints were normalized in time and averaged to obtain the mean cycle of each joint, among participants. The mean speed in water was 40% lower than that of the dry-land condition. Longer stride duration and shorter stride distance were found in the underwater walking. In the sagittal plane, the knee was more flexed (approximate to 23 degrees) and the ankle more dorsiflexed (approximate to 9 degrees) at heel strike, and the hip was more flexed at toe-off (approximate to 13 degrees) in water than on land. On the frontal plane in the underwater walking, smoother joint angle patterns were observed for thorax-pelvis and hip, and ankle was more inversed at toe-off (approximate to 7 degrees) and showed a more inversed mean value (approximate to 7 degrees). The results were mainly explained by the effect of the speed in the water as supported by the linear mixed models analysis performed. Thus, it seemed that the combination of speed and environment triggered modifications in the joint angles in underwater gait more than these two factors considered separately. The inertial and magnetic sensors, by means of fast set-up and data analysis, can supply an immediate gait analysis report to the therapist during the aquatic therapy session.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Wearable Joint Kinematic Monitoring System Using Inertial and Magnetic Sensors
    Kobashi, Syoji
    Kawano, Keiro
    Tsumori, Yohei
    Yoshiya, Shiinchi
    Hata, Yutaka
    2009 IEEE WORKSHOP ON ROBOTIC INTELLIGENCE IN INFORMATIONALLY STRUCTURED SPACE, 2009, : 25 - +
  • [2] Horse gait analysis using wearable inertial sensors and machine learning
    Rana, Manju
    Mittal, Vikas
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2023,
  • [3] Improving the reliability of underwater gait analysis using wearable pressure and inertial sensors
    Monoli, Cecilia
    Galli, Manuela
    Tuhtan, Jeffrey A.
    PLOS ONE, 2024, 19 (03):
  • [4] Objective Measures of Ataxic Gait Using Wearable Inertial Sensors
    El-Gohary, M.
    Horak, L.
    Gomez, C.
    MOVEMENT DISORDERS, 2018, 33 : S292 - S292
  • [5] Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review
    Prisco, Giuseppe
    Pirozzi, Maria Agnese
    Santone, Antonella
    Esposito, Fabrizio
    Cesarelli, Mario
    Amato, Francesco
    Donisi, Leandro
    DIAGNOSTICS, 2025, 15 (01)
  • [6] Multimodal Gait Analysis based on Wearable Inertial and Microphone Sensors
    Wang, Cheng
    Wang, Xiangdong
    Long, Zhou
    Yuan, Jing
    Qian, Yueling
    Li, Jintao
    2017 IEEE SMARTWORLD, UBIQUITOUS INTELLIGENCE & COMPUTING, ADVANCED & TRUSTED COMPUTED, SCALABLE COMPUTING & COMMUNICATIONS, CLOUD & BIG DATA COMPUTING, INTERNET OF PEOPLE AND SMART CITY INNOVATION (SMARTWORLD/SCALCOM/UIC/ATC/CBDCOM/IOP/SCI), 2017,
  • [7] Gait Analysis Using Wearable Sensors
    Tao, Weijun
    Liu, Tao
    Zheng, Rencheng
    Feng, Hutian
    SENSORS, 2012, 12 (02) : 2255 - 2283
  • [8] Gait Analysis Using Wearable Sensors
    Bhosale, Tanmav
    Kudale, Hemant
    Kumthekar, Varun
    Garude, Shreyash
    Dhumal, Prasad
    2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 267 - 269
  • [9] Experimental evaluation of indoor magnetic distortion effects on gait analysis performed with wearable inertial sensors
    Palermo, E.
    Rossi, S.
    Patane, F.
    Cappa, P.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (03) : 399 - 415
  • [10] Estimation of Step Length and Gait Asymmetry Using Wearable Inertial Sensors
    Wang, Lei
    Sun, Yun
    Li, Qingguo
    Liu, Tao
    IEEE SENSORS JOURNAL, 2018, 18 (09) : 3844 - 3851