Infrared spectral responsivity scale realization and validations

被引:12
作者
Eppeldauer, George P. [1 ]
Podobedov, Vyacheslav B. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
WORKING-STANDARD RADIOMETERS; POWER; NIST;
D O I
10.1364/AO.51.006003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An InSb working standard radiometer, first calibrated at the National Institute of Standards and Technology (NIST) in 1999 against a cryogenic bolometer, was recently calibrated against a newly developed low-noise-equivalent-power pyroelectric transfer standard detector. The pyroelectric transfer standard, which can operate at the output of a monochromator, holds the newly realized NIST spectral power responsivity scale between 1.7 and 14 mu m with an uncertainty of 1% (k = 2). The InSb working standard was also measured at the National Physical Laboratory (NPL) of the United Kingdom in 1999. The less than 2% spectral power responsivity disagreements obtained on the InSb working standard (both from the 1999 NIST and NPL comparison and also against the pyroelectric standard) validate the three independently realized power responsivity scales and verify the long-term stability of the InSb working standard. The InSb working standard was also used in irradiance measurement mode to validate the previously determined spectral irradiance responsivity of four narrowband InSb radiometers that were applied to calibrate IR target simulators. The uncertainty of the present spectral irradiance responsivity scale held by the InSb working standard is 2.5% (k = 2) in the 2 to 5.2 mu m wavelength range. (c) 2012 Optical Society of America
引用
收藏
页码:6003 / 6008
页数:6
相关论文
共 9 条
[1]   Spectral power and irradiance responsivity calibration of InSb working-standard radiometers [J].
Eppeldauer, G ;
Rácz, M .
APPLIED OPTICS, 2000, 39 (31) :5739-5744
[2]   Low NEP pyroelectric radiometer standards [J].
Eppeldauer, G. P. ;
Zeng, J. ;
Yoon, H. W. .
INFRARED TECHNOLOGY AND APPLICATIONS XXXIV, PTS 1 AND 2, 2008, 6940
[3]   Extension of the NIST spectral responsivity scale to the infrared using improved-NEP pyroelectric detectors [J].
Eppeldauer, G. P. ;
Zeng, J. ;
Yoon, H. W. ;
Wilthan, B. ;
Larason, T. C. ;
Hanssen, L. M. .
METROLOGIA, 2009, 46 (04) :S155-S159
[4]   Short-wave infrared radiometers design and characterizations [J].
Eppeldauer, George P. ;
Yoon, Howard W. .
INFRARED TECHNOLOGY AND APPLICATIONS XXXIII, 2007, 6542
[5]   Spectral irradiance responsivity measurements between 1 μm and 5 μm [J].
Eppeldauer, GP ;
Rice, JP ;
Zhang, J ;
Lykke, KR .
INFRARED SPACEBORNE REMOTE SENSING XII, 2004, 5543 :248-257
[6]   InSb working standard radiometers [J].
Eppeldauer, GP ;
Migdall, AL ;
Hanssen, LM .
METROLOGIA, 1998, 35 (04) :485-490
[7]   Geometric area measurements of circular apertures for radiometry at NIST [J].
Fowler, J ;
Litorja, M .
METROLOGIA, 2003, 40 (01) :S9-S12
[8]   Realization of an infrared spectral radiant power response scale on a cryogenic bolometer [J].
Migdall, A ;
Eppeldauer, G .
METROLOGIA, 1998, 35 (04) :307-315
[9]  
Zeng J N, 2009, P SOC PHOTO-OPT INS, V7453