Liver fibrosis evaluation using real-time shear wave elastography: Applicability and diagnostic performance using methods without a gold standard

被引:135
|
作者
Poynard, Thierry [1 ]
Munteanu, Mona [2 ]
Luckina, Elena [1 ,3 ]
Perazzo, Hugo [1 ]
Ngo, Yen [1 ]
Royer, Luca [1 ]
Fedchuk, Larysa [1 ]
Sattonnet, Florence [1 ]
Pais, Raluca [1 ]
Lebray, Pascal [1 ]
Rudler, Marika [1 ]
Thabut, Dominique [1 ]
Ratziu, Vlad [1 ]
机构
[1] APHP UPMC Liver Ctr, F-75651 Paris 13, France
[2] BioPredictive, Res Unit, Paris, France
[3] ANRS, Paris, France
关键词
Fibrosis; Obuchowski measure; Concordance; FibroTest; FibroSure; FibroScan; Aixplorer; Non-invasive methods; STIFFNESS MEASUREMENT; HEPATITIS-C; ACCURACY; FIBROTEST; BIOPSY;
D O I
10.1016/j.jhep.2012.12.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Real-time shear wave elastography (SWE) is a new two-dimensional transient elastography which had no assessment of factors associated with reliability, and had limited comparisons with other validated fibrosis biomarkers. The aim was to assess the applicability and performances of SWE for the diagnosis of fibrosis as compared with FibroTest (FT) and liver stiffness measurement (LSM) by transient elastography using two probes (TE-M and TE-XL). Methods: Without a gold standard, the strength of concordance, discordance analysis and latent class analysis (LCM) were applied. Results: 422 patients were included. The applicability of SWE (90.0%) was significantly lower than that of FT (97.9%; p <0.0001) and did not differ from those of TE-M (90.5%) and TE-XL (90.3%); it was higher though for SWE (86%) in 22 patients with ascites vs. 55% using TE-M (p = 0.04). For the diagnosis of all fibrosis stages as presumed by FT, the performance of SWE was highly significant (Obuchowski measure 0.807 +/- 0.013 [m +/- se]), but lower than those of TE-M (0.852; p = 0.0007) and TE-XL (0.834; p = 0.046). SWE had a low performance for discrimination between F0 and F1. For the diagnosis of cirrhosis using LCM, SWE specificities were all equal to 99%, and SWE sensitivities ranged from 0.47 to 0.64. For the diagnosis of non-cirrhotic stages, the results were heterogeneous. Conclusions: The performance of SWE for the diagnosis of cirrhosis was similar to those of FT and TE. SWE applicability was lower than that of FT, but greater than that of TE in patients with ascites. (c) 2013 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 50 条
  • [21] The Performance of a 2-Dimensional Shear-Wave Elastography Technique for Predicting Different Stages of Liver Fibrosis Using Transient Elastography as the Control Method
    Bende, Felix
    Sporea, Ioan
    Sirli, Roxana
    Nistorescu, Silviu
    Fofiu, Renata
    Baldea, Victor
    Popescu, Alina
    ULTRASOUND QUARTERLY, 2021, 37 (02) : 97 - 104
  • [22] IMAGE PROCESSING PIPELINE FOR LIVER FIBROSIS CLASSIFICATION USING ULTRASOUND SHEAR WAVE ELASTOGRAPHY
    Brattain, Laura J.
    Ozturk, Arinc
    Telfer, Brian A.
    Dhyani, Manish
    Grajo, Joseph R.
    Samir, Anthony E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (10) : 2667 - 2676
  • [23] NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN A RAT MODEL: SHEAR WAVE ELASTICITY IMAGING VERSUS REAL-TIME ELASTOGRAPHY
    Lin, Sen-hao
    Ding, Hong
    Mao, Feng
    Xue, Li-Yun
    Lv, Wei-wei
    Zhu, Hong-Guang
    Huang, Bei-Jian
    Wang, Wen-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (07) : 1215 - 1222
  • [24] Noninvasive evaluation of hepatic fibrosis using serum fibrotic markers, transient elastography (FibroScan) and real-time tissue elastography
    Tatsumi, Chie
    Kudo, Masatoshi
    Ueshima, Kazuomi
    Kitai, Satoshi
    Takahashi, Shunsuke
    Inoue, Tatsuo
    Minami, Yasunori
    Chung, Hobyung
    Maekawa, Kiyoshi
    Fujimoto, Kenji
    Akiko, Tonomura
    Takeshi, Mitake
    INTERVIROLOGY, 2008, 51 : 27 - 33
  • [25] NORMAL LIVER STIFFNESS IN HEALTHY ADULTS ASSESSED BY REAL-TIME SHEAR WAVE ELASTOGRAPHY AND FACTORS THAT INFLUENCE THIS METHOD
    Huang, Zeping
    Zheng, Jian
    Zeng, Jie
    Wang, Xiaoli
    Wu, Tao
    Zheng, Rongqin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (11) : 2549 - 2555
  • [26] Performance of 2-Dimensional Ultrasound Shear Wave Elastography in Liver Fibrosis Detection Using Magnetic Resonance Elastography as the Reference Standard A Pilot Study
    Song, Pengfei
    Mellema, Daniel C.
    Sheedy, Shannon P.
    Meixner, Duane D.
    Karshen, Ryan M.
    Urban, Matthew W.
    Manduca, Armando
    Sanchez, William
    Callstrom, Matthew R.
    Greenleaf, James F.
    Chen, Shigao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) : 401 - 412
  • [27] Diagnostic performance on multiple parameters of real-time ultrasound shear wave elastography for evaluating nonalcoholic fatty liver disease: A rabbit model
    Lei, Pinggui
    Zhang, Piaochen
    Xu, Hengtian
    Liu, Qianijao
    Wang, Yan
    Wang, Pingxian
    Duan, Qinghong
    Liu, Jing
    Zhou, Shi
    Qian, Wei
    Jiao, Jun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1187 - 1197
  • [28] Real time shear wave elastography in chronic liver diseases: Accuracy for predicting liver fibrosis, in comparison with serum markers
    Jeong, Jae Yoon
    Kim, Tae Yeob
    Sohn, Joo Hyun
    Kim, Yongsoo
    Jeong, Woo Kyoung
    Oh, Young-Ha
    Yoo, Kyo-Sang
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (38) : 13920 - 13929
  • [29] Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B
    Wu, Tao
    Wang, Ping
    Zhang, Ting
    Zheng, Jian
    Li, Shuoyang
    Zeng, Jie
    Kudo, Masatoshi
    Zheng, Rongqin
    DIGESTIVE DISEASES, 2016, 34 (06) : 640 - 649
  • [30] Assessment of Substantial Liver Fibrosis by Real-time Shear Wave Elastography in Methotrexate-Treated Patients With Rheumatoid Arthritis
    Kim, Tae Yeob
    Kim, Ji Yeoun
    Sohn, Joo Hyun
    Lee, Hye-Soon
    Bang, So-Young
    Kim, Yongsoo
    Kim, Min Yeong
    Jeong, Woo Kyoung
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (09) : 1621 - 1630