Liver fibrosis evaluation using real-time shear wave elastography: Applicability and diagnostic performance using methods without a gold standard

被引:135
|
作者
Poynard, Thierry [1 ]
Munteanu, Mona [2 ]
Luckina, Elena [1 ,3 ]
Perazzo, Hugo [1 ]
Ngo, Yen [1 ]
Royer, Luca [1 ]
Fedchuk, Larysa [1 ]
Sattonnet, Florence [1 ]
Pais, Raluca [1 ]
Lebray, Pascal [1 ]
Rudler, Marika [1 ]
Thabut, Dominique [1 ]
Ratziu, Vlad [1 ]
机构
[1] APHP UPMC Liver Ctr, F-75651 Paris 13, France
[2] BioPredictive, Res Unit, Paris, France
[3] ANRS, Paris, France
关键词
Fibrosis; Obuchowski measure; Concordance; FibroTest; FibroSure; FibroScan; Aixplorer; Non-invasive methods; STIFFNESS MEASUREMENT; HEPATITIS-C; ACCURACY; FIBROTEST; BIOPSY;
D O I
10.1016/j.jhep.2012.12.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Real-time shear wave elastography (SWE) is a new two-dimensional transient elastography which had no assessment of factors associated with reliability, and had limited comparisons with other validated fibrosis biomarkers. The aim was to assess the applicability and performances of SWE for the diagnosis of fibrosis as compared with FibroTest (FT) and liver stiffness measurement (LSM) by transient elastography using two probes (TE-M and TE-XL). Methods: Without a gold standard, the strength of concordance, discordance analysis and latent class analysis (LCM) were applied. Results: 422 patients were included. The applicability of SWE (90.0%) was significantly lower than that of FT (97.9%; p <0.0001) and did not differ from those of TE-M (90.5%) and TE-XL (90.3%); it was higher though for SWE (86%) in 22 patients with ascites vs. 55% using TE-M (p = 0.04). For the diagnosis of all fibrosis stages as presumed by FT, the performance of SWE was highly significant (Obuchowski measure 0.807 +/- 0.013 [m +/- se]), but lower than those of TE-M (0.852; p = 0.0007) and TE-XL (0.834; p = 0.046). SWE had a low performance for discrimination between F0 and F1. For the diagnosis of cirrhosis using LCM, SWE specificities were all equal to 99%, and SWE sensitivities ranged from 0.47 to 0.64. For the diagnosis of non-cirrhotic stages, the results were heterogeneous. Conclusions: The performance of SWE for the diagnosis of cirrhosis was similar to those of FT and TE. SWE applicability was lower than that of FT, but greater than that of TE in patients with ascites. (c) 2013 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 50 条
  • [1] Evaluation of fatty liver fibrosis in rabbits using real-time shear wave elastography
    Lu, Yongping
    Wei, Jia
    Tang, Yueyue
    Yuan, Yuan
    Huang, Yanling
    Zhang, Yong
    Li, Yunyan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 8 (02) : 355 - 362
  • [2] Diagnostic role of real-time shear wave elastography on staging of liver fibrosis
    Xue, Yan
    Zhu, Qing
    Chen, Yuanzheng
    Bai, Nan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (08): : 12911 - 12917
  • [3] Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    Ferraioli, Giovanna
    Tinelli, Carmine
    Zicchetti, Mabel
    Above, Elisabetta
    Poma, Gianluigi
    Di Gregorio, Marta
    Filice, Carlo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3102 - 3106
  • [4] Liver Fibrosis Evaluation Using Real-time Shear Wave Elastography in Hepatitis C-Monoinfected and Human Immunodeficiency Virus/Hepatitis C-Coinfected Patients
    Verlinden, Wim
    Bourgeois, Stefan
    Gigase, Pierre
    Thienpont, Clara
    Vonghia, Luisa
    Vanwolleghem, Thomas
    Michielsen, Peter
    Francque, Sven
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (06) : 1299 - 1308
  • [5] Assessment of fibrosis during the development of fatty liver in rabbits using real-time shear-wave elastography
    Lu, Yong-ping
    Wei, Jia
    Xu, Li-rong
    Tang, Yue-yue
    Yuan, Yuan
    Zhang, Yong
    Li, Yun-yan
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (06) : 921 - 928
  • [6] Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Zicchetti, Mabel
    Filice, Gaetano
    Filice, Carlo
    HEPATOLOGY, 2012, 56 (06) : 2125 - 2133
  • [7] Noninvasive Evaluation of Liver Fibrosis Using Real-time Tissue Elastography and Transient Elastography (FibroScan)
    Meng, Fankun
    Zheng, Ying
    Zhang, Qi
    Mu, Xiaojie
    Xu, Xiaoluan
    Zhang, Haiying
    Ding, Lei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (03) : 403 - 410
  • [8] Liver fibrosis staging with a new 2D-shear wave elastography using comb-push technique: Applicability, reproducibility, and diagnostic performance
    Lee, Sang Min
    Lee, Jeong Min
    Kang, Hyo-Jin
    Yang, Hyung Kung
    Yoon, Jeong Hee
    Chang, Won
    An, Su Joa
    Lee, Kyoung Bun
    Baek, Seung Yon
    PLOS ONE, 2017, 12 (05):
  • [9] Utility of real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C infection without cirrhosis: Comparison of liver fibrosis indices
    Tada, Toshifumi
    Kumada, Takashi
    Toyoda, Hidenori
    Ito, Takanori
    Sone, Yasuhiro
    Okuda, Seiji
    Tsuji, Nozomi
    Imayoshi, Yumi
    Yasuda, Eisuke
    HEPATOLOGY RESEARCH, 2015, 45 (10) : E122 - E129
  • [10] Diagnostic Accuracy of Real-Time Shear Wave Elastography for Staging of Liver Fibrosis: A Meta-Analysis
    Li, Changtian
    Zhang, Changsheng
    Li, Junlai
    Huo, Huiping
    Song, Danfei
    MEDICAL SCIENCE MONITOR, 2016, 22 : 1349 - 1359