MRI in patients with chronic obstructive uropathy and compromised renal function: a sole method for morphological and functional assessment

被引:11
作者
Abou El-Ghar, M. E. [1 ]
Shokeir, A. A. [1 ]
Refaie, H. F. [1 ]
El-Diasty, T. A. [1 ]
机构
[1] Mansoura Univ, Urol & Nephrol Ctr, Mansoura, Egypt
关键词
D O I
10.1259/bjr/30109090
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the role of MRI as a single modality for anatomical and functional evaluation of obstructed kidneys in patients with compromised renal function. The study included 96 adults with unilateral or bilateral chronic obstructive hydronephrosis and compromised renal function (serum creatinine >= 1.8 mg dl(-1)). Patients were subjected to gadolinium-enhanced MRI (Gd-MRI), which determined the anatomy of both renoureteral units, as well as their function, through selective calculation of the glomerular filtration rate (GFR) of each kidney. All patients underwent a technetium-99m diethylenetriamine-pentaacetic acid renal scan. Moreover, a correlation was made between the GFR determined by Gd-MRI and the isotope GFR. The study comprised 59 males and 37 females. A comprehensive MRI study detected the cause of obstruction in all kidneys with non-calcular obstruction (sensitivity of 100%) and in 21 kidneys with calcular obstruction (sensitivity of 70%). The overall sensitivity of MRI combined with plain X-ray of the abdomen and ultrasound in the detection of various causes of obstruction was 97%. A comparison between the isotope GFR of the obstructed kidneys and the corresponding magnetic resonance urography (MRU) GFR showed perfect correlation. In conclusion, combined static and dynamic MRU is a promising technique that allows anatomical and functional evaluation of obstructed kidneys in patients with impaired renal function but, owing to the possible risk of nephrogenic systemic fibrosis in patients with a GFR < 30 ml min(-1) the lowest possible dose of the most stable Gd-macrocyclic chelates should be used if a functional MRI study is required. (C) 2008 The British Institute of Radiology.
引用
收藏
页码:624 / 629
页数:6
相关论文
共 20 条
[1]  
Blandino A, 2001, ACTA RADIOL, V42, P532
[2]   NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
DUMOULIN, CL ;
BUONOCORE, MH ;
OPSAHL, LR ;
KATZBERG, RW ;
DARROW, RD ;
MORRIS, TW ;
BATEY, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :370-378
[3]   Magnetic resonance imaging as a sole method for the morphological and functional evaluation of live kidney donors [J].
El-Diasty, TA ;
El-Ghar, MEA ;
Shokeir, AA ;
Gad, HM ;
Wafa, EW ;
El-Azab, ME ;
El-Din, ABS ;
Ghoneim, MA .
BJU INTERNATIONAL, 2005, 96 (01) :111-116
[4]   Contrast enhanced spiral computerized tomography in patients with chronic obstructive uropathy and normal serum creatinine: A single session for anatomical and functional assessment [J].
El-Ghar, MEA ;
Shokeir, AA ;
El-Diasty, T ;
Refaie, HF ;
Gad, HM ;
El-Dein, ABS .
JOURNAL OF UROLOGY, 2004, 172 (03) :985-988
[5]   Evaluation of glomerular function in individual kidneys using dynamic magnetic resonance imaging [J].
Fukuda, Y ;
Watanabe, H ;
Tomita, T ;
Katayama, H ;
Miyano, T ;
Yabuta, K .
PEDIATRIC RADIOLOGY, 1996, 26 (05) :324-328
[6]   Gadolinium - a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? [J].
Grobner, T .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (04) :1104-1108
[7]   Magnetic resonance urography enhanced by gadolinium and diuretics:: a comparison with conventional urography in diagnosing the cause of ureteric obstruction [J].
Jung, P ;
Brauers, A ;
Nolte-Ernsting, CA ;
Jakse, G ;
Günther, RW .
BJU INTERNATIONAL, 2000, 86 (09) :960-965
[8]   Functional, dynamic, and anatomic MR urography: Feasibility and preliminary findings [J].
Katzberg, RW ;
Buonocore, MH ;
Ivanovic, M ;
Pellot-Barakat, C ;
Ryan, JM ;
Whang, K ;
Brock, JM ;
Jones, CD .
ACADEMIC RADIOLOGY, 2001, 8 (11) :1083-1099
[9]  
KATZBERG RW, 1994, MAGN RESON MED, V32, P370
[10]   Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis [J].
Kuo, Phillip H. ;
Kanal, Emanuel ;
Abu-Alfa, Ali K. ;
Cowper, Shawn E. .
RADIOLOGY, 2007, 242 (03) :647-649