Design of CUBE, a Cable-Driven Device for Upper and Lower Limb Exercising

被引:8
作者
Cafolla, Daniele [1 ]
Russo, Matteo [2 ]
Carbone, Giuseppe [2 ]
机构
[1] Tech Univ Cluj Napoca, CESTER Res Ctr Ind Robot Simulat & Testing, Cluj Napoca, Romania
[2] Univ Cassino & Southern Latium, LARM Lab Robot & Mechatron, Cassino, Italy
来源
NEW TRENDS IN MEDICAL AND SERVICE ROBOTICS: ADVANCES IN THEORY AND PRACTICE | 2019年 / 65卷
关键词
Cable-driven robots; Medical robots; Parallel robots; Rehabilitation devices; Kinematics;
D O I
10.1007/978-3-030-00329-6_29
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper introduces CUBE, a cable-driven parallel robot for the assistance of patients in rehabilitation exercising for both upper and lower limb. The system is characterized by a lightweight foldable structure that is easy to set-up in different configurations. It can adapt to different exercises and to the available environment. Its cable-driven design makes it inherently safe in human/robot interactions also due to the extremely low inertia. The design is presented with its kinematic and dynamic analysis and validated through a first prototype.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 16 条
[1]   Training modalities in robot-mediated upper limb rehabilitation in stroke: a framework for classification based on a systematic review [J].
Basteris, Angelo ;
Nijenhuis, Sharon M. ;
Stienen, Arno H. A. ;
Buurke, Jaap H. ;
Prange, Gerdienke B. ;
Amirabdollahian, Farshid .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
[2]   Design Issues for an Inherently Safe Robotic Rehabilitation Device [J].
Carbone, Giuseppe ;
Gherman, Bogdan ;
Ulinici, Ionut ;
Vaida, Calin ;
Pisla, Doina .
ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, 2018, 49 :1025-1032
[3]   ROAD: domestic assistant and rehabilitation robot [J].
Carrera, Isela ;
Moreno, Hector A. ;
Saltaren, Roque ;
Perez, Carlos ;
Puglisi, Lisandro ;
Garcia, Cecilia .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (10) :1201-1211
[4]  
Ceccarelli M, 2009, PROCEEDINGS OF THE R
[5]  
Fanin C., 2003, ICORR 2003
[6]   Characterization of a Cable-Based Parallel Mechanism for Measurement Purposes# [J].
Hernandez-Martinez, Eusebio E. ;
Ceccarelli, Marco ;
Carbone, Giuseppe ;
Lopez-Cajun, Carlos S. ;
Jauregui-Correa, Juan C. .
MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2010, 38 (01) :25-49
[7]   Seven Capital Devices for the Future of Stroke Rehabilitation [J].
Iosa, M. ;
Morone, G. ;
Fusco, A. ;
Bragoni, M. ;
Coiro, P. ;
Multari, M. ;
Venturiero, V. ;
De Angelis, D. ;
Pratesi, L. ;
Paolucci, S. .
STROKE RESEARCH AND TREATMENT, 2012, 2012
[8]  
ISO Standards, 2016, 150662016 PD ISOTS
[9]  
Kim S., 2000, P ACM S VIRT REAL SO
[10]   Upper limb robot mediated stroke therapy - GENTLE/s approach [J].
Loureiro, R ;
Amirabdollahian, F ;
Topping, M ;
Driessen, B ;
Harwin, W .
AUTONOMOUS ROBOTS, 2003, 15 (01) :35-51