Surface neutralization and H2S oxidation at early stages of sewer corrosion: Influence of temperature, relative humidity and H2S concentration

被引:144
作者
Joseph, Antony P. [1 ]
Keller, Juerg [1 ]
Bustamante, Heriberto [2 ]
Bond, Philip L. [1 ]
机构
[1] Univ Queensland, Adv Water Management Ctr, Brisbane, Qld 4072, Australia
[2] Sydney Water, Parramatta, NSW 2124, Australia
基金
澳大利亚研究理事会;
关键词
Hydrogen sulphide; Temperature; Relative humidity; Sewer corrosion; SULFIDE OXIDATION; HYDROGEN-SULFIDE; WASTE-WATER; CONCRETE; KINETICS; SULFUR; PH; SEAWATER; SLUDGE; PIPES;
D O I
10.1016/j.watres.2012.05.011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
While the involvement of a range of environmental factors in sewer corrosion is known, a comprehensive understanding of the processes involved and the exact role of individual environmental factors in sewer corrosion is still lacking. The corrosion of concrete in sewer systems is reported to be initiated through chemical reactions (involving H2S and CO2) that lower the surface pH to a level then conducive for biological activity. However, the specific influence of environmental variables, such as H2S level, temperature, and relative humidity etc. remains unclear; although, they are expected to control these initial surface reactions of the concrete sewer pipe. We examined changes in the surface chemistry of concrete during the early stages of corrosion by exposing concrete coupons to thirty-six independent conditions in well-controlled laboratory chambers that simulated conditions typically found in various sewer environments across Australia. The conditions employed were combinations of six H2S levels, three gas-phase temperatures and two relative humidity levels. Our results indicate that the role of CO2 on initial surface pH reduction is insignificant when compared to the influence of H2S. Within the first 12 months, a decrease in surface pH by 4.8 units was observed for coupons exposed to 30 degrees C and 50 ppm H2S, while significantly lower pH reductions of 3.5 and 1.8 units were detected for coupons exposed to 25 degrees C and 18 degrees C respectively, and 50 ppm H2S. Elemental sulphur was found to be the major oxidation product of H2S and elevated concentrations were detected at the higher levels of H2S, temperature and relative humidity. More significantly, the data obtained from the controlled chamber experiments correlated with those obtained from the field-exposed coupons. Hence, these findings can be extended to real sewer corrosion processes. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4235 / 4245
页数:11
相关论文
共 31 条
[1]  
Andrey B., 2005, IND ENG CHEM RES, V44, P530
[2]  
Andrey B., 2004, PREPRINT PAPERS AM C, V49, P817
[3]  
Apgar D., 2007, 04CTS1 WERF
[4]   The experimental investigation of concrete carbonation depth [J].
Chang, Cheng-Feng ;
Chen, Jing-Wen .
CEMENT AND CONCRETE RESEARCH, 2006, 36 (09) :1760-1767
[5]   KINETICS OF OXIDATION OF AQUEOUS SULFIDE BY O2 [J].
CHEN, KY ;
MORRIS, JC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1972, 6 (06) :529-&
[6]   OXYGENATION OF HYDROGEN SULFIDE IN SEAWATER AT CONSTANT SALINITY, TEMPERATURE, AND PH [J].
CLINE, JD ;
RICHARDS, FA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1969, 3 (09) :838-&
[7]   Experimental research and prediction of the effect of chemical and biogenic sulfuric acid on different types of commercially produced concrete sewer pipes [J].
De Belie, N ;
Monteny, J ;
Beeldens, A ;
Vincke, E ;
Van Gemert, D ;
Verstraete, W .
CEMENT AND CONCRETE RESEARCH, 2004, 34 (12) :2223-2236
[8]   The effect of chemical oxidation on the biological sulfide oxidation by an alkaliphilic sulfoxidizing bacterial consortium [J].
Gonzalez-Sanchez, Armando ;
Revah, Sergio .
ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (02) :292-298
[9]  
Guadalupe Ma, 2007, 07514 NACE
[10]   MICROBIAL ECOLOGY OF CROWN CORROSION IN SEWERS [J].
ISLANDER, RL ;
DEVINNY, JS ;
MANSFELD, F ;
POSTYN, A ;
HONG, S .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1991, 117 (06) :751-770