Comparison of the Glidescope® and Airtraq® optical laryngoscopes in patients undergoing direct microlaryngoscopy

被引:35
作者
Lange, M. [1 ]
Frommer, M. [1 ]
Redel, A. [1 ]
Trautner, H. [1 ]
Hampel, J. [1 ]
Kranke, P. [1 ]
Kehl, F. [2 ]
Scholtz, L. U. [1 ]
Roewer, N. [1 ]
机构
[1] Univ Wurzburg, Dept Otorhinolaryngol Plast Aesthet & Reconstruct, D-97080 Wurzburg, Germany
[2] Klinikum Karlsruhe, Dept Anaesthesia & Crit Care, Karlsruhe, Germany
关键词
TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; VIDEO LARYNGOSCOPE; DIFFICULT LARYNGOSCOPY; LARYNGEAL MASK; VIDEOLARYNGOSCOPE GLIDESCOPE(R); ENDOTRACHEAL INTUBATION; ANKYLOSING-SPONDYLITIS; AIRWAY MANAGEMENT; NOVICE PERSONNEL;
D O I
10.1111/j.1365-2044.2008.05781.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Optical laryngoscopes have been developed to facilitate difficult airway management. The Airtraq((R)) is a single-use device and the GlideScope((R)) is reusable. In this study, the Airtraq and the Glidescope were compared in 60 ASA I-III patients with tumours of the upper airway undergoing direct endoscopic microlaryngoscopy. Patients were randomly assigned to the Airtraq or the Glidescope group and the Cormack and Lehane grade was assessed by Macintosh laryngoscopy prior to tracheal intubation. There were no differences in tracheal intubation success rates or duration of intubation attempts between both devices. The Cormack and Lehane grade was improved in 77% and 82% of cases in the Airtraq and Glidescope group, respectively. Blood traces on the device and traumatic pharyngeal lesions were found more frequently in the Airtraq group. The Airtraq and Glidescope laryngoscopes are valuable tools for the management of patients with potentially difficult airways with the Glidescope appearing to be less traumatic.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 26 条
[1]   An evaluation of the GlideScope®, a new video laryngoscope for difficult airways:: A manikin study [J].
Benjamin, F. J. ;
Boon, D. ;
French, R. A. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) :517-521
[2]   Emergency use of the Airtraq laryngoscope in traumatic asphyxia: case report [J].
Black, John J. M. .
EMERGENCY MEDICINE JOURNAL, 2007, 24 (07) :509-510
[3]   Eliminating protein from reusable laryngeal mask airways [J].
Coetzee, GJ .
ANAESTHESIA, 2003, 58 (04) :346-352
[4]  
Cooper RM, 2005, CAN J ANAESTH, V52, P191, DOI 10.1007/BF03027728
[5]  
Cooper RM, 2003, CAN J ANAESTH, V50, P611, DOI 10.1007/BF03018651
[6]   Tracheal intubation using the Airtraq® in morbid obese patients undergoing emergency cesarean delivery [J].
Dhonneur, Gilles ;
Ndoko, Serge ;
Amathieu, Roland ;
el Housseini, Lodfi ;
Poncelet, Christophe ;
Tual, Loic .
ANESTHESIOLOGY, 2007, 106 (03) :629-630
[7]   Comparison of the GlideScope® video laryngoscope vs. the intubating laryngeal mask for females with normal airways [J].
Fun, W. L. L. ;
Lim, Y. ;
Teoh, W. H. L. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (06) :486-491
[8]   Successful first time use of the portable GlideScope® videolaryngoscope in a patient with severe ankylosing spondylitis [J].
Gooden, CK .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (07) :777-778
[9]   Clinical comparisons between GlideScope® video laryngoscope and Trachlight® in simulated cervical spine instability [J].
Huang, Wei-Tai ;
Huang, Chin-Yi ;
Chung, Yung-Tai .
JOURNAL OF CLINICAL ANESTHESIA, 2007, 19 (02) :110-114
[10]   Comparison of the GlideScope video laryngoscope and Macintosh laryngoscope in simulated tracheal intubation scenarios [J].
Kim, H. J. ;
Chung, S. P. ;
Park, I. C. ;
Cho, J. ;
Lee, H. S. ;
Park, Y. S. .
EMERGENCY MEDICINE JOURNAL, 2008, 25 (05) :279-282