Comparison of the Mechanical Behaviour of Standard and Auxetic Foams by X-ray Computed Tomography and Digital Volume Correlation

被引:43
|
作者
Pierron, F. [1 ]
McDonald, S. A. [2 ]
Hollis, D. [3 ]
Fu, J. [4 ]
Withers, P. J. [2 ]
Alderson, A. [5 ]
机构
[1] Univ Southampton, Fac Engn & Environm, Southampton SO17 1BJ, Hants, England
[2] Univ Manchester, Sch Mat, Manchester M1 7HS, Lancs, England
[3] LaVis UK Ltd, Grove OX12 9FF, Oxon, England
[4] Arts & Metiers ParisTech, LMPF, F-51000 Chalons Sur Marne, France
[5] Sheffield Hallam Univ, Fac ACES, Mat & Engn Res Inst, Sheffield S1 1WB, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
auxetic foam; digital volume correlation; low density polymeric foam; Poisson's ratio; X-ray CT; MAGNETIC-RESONANCE ELASTOGRAPHY; DISPLACEMENT MEASUREMENT; STRAIN-MEASUREMENT; IMAGE CORRELATION; FIELD; MICROTOMOGRAPHY; INTERFEROMETRY; PERFORMANCE; TISSUE; CRACKS;
D O I
10.1111/str.12053
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The tensile behaviour of standard and auxetic polyurethane foams are contrasted by digital volume correlation of 3D images collected by in situ X-ray computed tomography (CT). It was found that subset sizes of 32 and 64 voxels for the auxetic and standard foams were optimal for strain resolutions in the order of 0.1%. For the standard foam, good uniformity of strain was observed at low strains giving a tangent Poisson's ratio of 0.5. Some heterogeneity of strain was observed at higher strains, which may be related to the fixtures. The behaviour of the auxetic foam was totally different, with strain being spatially heterogeneous with transverse strains both positive and negative but giving a negative Poisson's ratio on average. This suggests that the unfolding tendency of some groups of cells was higher than others because of the complex frozen starting microstructure. Further different methods of deriving Poisson's ratio gave different results. Besides revealing interesting microstuctural mechanisms of transverse straining, the study also shows digital volume correlation of tomography sequences to be the perfect tool to study complex mechanical behaviour of cellular materials.
引用
收藏
页码:467 / 482
页数:16
相关论文
共 50 条
  • [1] Assessment of the deformation of low density polymeric auxetic foams by X-ray tomography and digital volume correlation
    Pierron, F.
    McDonald, S. A.
    Hollis, D.
    Withers, P. J.
    Alderson, A.
    ADVANCES IN EXPERIMENTAL MECHANICS VIII, 2011, 70 : 93 - +
  • [2] Improving Metrological Performance Estimation of Digital Volume Correlation: Application to X-Ray Computed Tomography
    Wantz, S.
    Brault, R.
    Pannier, Y.
    Valle, V.
    EXPERIMENTAL MECHANICS, 2025, 65 (02) : 269 - 282
  • [3] In-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation
    Brault, R.
    Germaneau, A.
    Dupre, J. C.
    Doumalin, P.
    Mistou, S.
    Fazzini, M.
    EXPERIMENTAL MECHANICS, 2013, 53 (07) : 1143 - 1151
  • [4] In situ tensile damage characterization of C/C composites through X-ray computed tomography and digital volume correlation
    Li, Wudi
    Jian, Yingjie
    Zhou, Xingui
    Wang, Honglei
    CERAMICS INTERNATIONAL, 2023, 49 (07) : 10471 - 10480
  • [5] Morphological evolution and internal strain mapping of pomelo peel using X-ray computed tomography and digital volume correlation
    Wang, B.
    Pan, B.
    Lubineau, G.
    MATERIALS & DESIGN, 2018, 137 : 305 - 315
  • [6] Localized Damage Analysis of Cement Mortar Using X-ray Computed Tomography In Situ Compressive Loading and Digital Volume Correlation
    Li, Na
    Zhao, Yanru
    Xing, Yongming
    He, Xiaoyan
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [7] Three-dimensional Analysis of an In Situ Double-torsion Test by X-ray Computed Tomography and Digital Volume Correlation
    Leplay, P.
    Rethore, J.
    Meille, S.
    Baietto, M. -C.
    Adrien, J.
    Chevalier, J.
    Maire, E.
    EXPERIMENTAL MECHANICS, 2013, 53 (07) : 1265 - 1275
  • [8] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [9] Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
    Bay, BK
    Smith, TS
    Fyhrie, DP
    Saad, M
    EXPERIMENTAL MECHANICS, 1999, 39 (03) : 217 - 226
  • [10] Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
    B. K. Bay
    T. S. Smith
    D. P. Fyhrie
    M. Saad
    Experimental Mechanics, 1999, 39 : 217 - 226