Field analysis of benzene, toluene, ethylbenzene and xylene in water by portable gas chromatography-microflame ionization detector combined with headspace solid-phase microextraction

被引:74
作者
Ji, Jie [1 ]
Deng, Chunhui [1 ]
Shen, Wenwen [1 ]
Zhang, Xiangmin [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
portable gas chromatography-microflame ionization detector; headspace solid-phase microextraction; benzene; toluene; ethylbenzene; xylene; field analysis;
D O I
10.1016/j.talanta.2005.11.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, portable gas chromatography-microflame ionization detection (portable GC-mu FID) coupled to headspace solid-phase microextraction (HS-SPME) was developed for the field analysis of benzene, toluene, ethylbenzene and xylene (BTEX) in water samples. The HS-SPME parameters such as fiber coating, extraction times, stirring rate, the ratio of headspace volume to sample volume, and sodium chloride concentration were studied. A 65 mu m poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 900 rpm, 3.0 ml of headspace (1.0 ml water sample in 4.0 ml vial), and 35% sodium chloride concentration (w/v) were respectively chosen for the best extraction response. An extraction time of 1.0 min was enough to extract BTEX in water samples. The relative standard deviation (R.S.D.) for the procedure varied from 5.4% to 8.3%. The method detection limits (MDLs) found were lower than 1.5 mu g/l, which was enough sensitive to detect the BTEX in water samples. The optimized method was applied to the field analysis of BTEX in wastewater samples. These experiment results show that portable GC-mu FID combined with HS-SPME is a rapid, simple and effective tool for field analysis. of BTEX in water samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:894 / 899
页数:6
相关论文
共 36 条
[1]   Analysis of BTEX and other substituted benzenes in water using headspace SPME-GC-FID: method validation [J].
Almeida, CMM ;
Boas, LV .
JOURNAL OF ENVIRONMENTAL MONITORING, 2004, 6 (01) :80-88
[2]   Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection [J].
Arambarri, I ;
Lasa, M ;
Garcia, R ;
Millán, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :193-203
[3]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[4]  
Battu C, 1998, J CHROMATOGR SCI, V36, P1
[5]   Effects of high-frequency electromagnetic treatment on the solid-phase extraction of aqueous benzene, naphthalene and phenol [J].
Beketov, VI ;
Parchinskii, VZ ;
Zorov, NB .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :65-73
[6]  
CHESTER TL, 1992, ANAL CHEM, V64, pR153
[7]   Headspace single-drop microextration for the detection of organotin compounds [J].
Colombini, V ;
Bancon-Montigny, C ;
Yang, L ;
Maxwell, P ;
Sturgeon, RE ;
Mester, Z .
TALANTA, 2004, 63 (03) :555-560
[8]   Determination of polychlorinated biphenyls in ash using dimethylsulfoxide microwave assisted extraction followed by solid-phase microextraction [J].
Criado, MR ;
Pereiro, IR ;
Torrijos, RC .
TALANTA, 2004, 63 (03) :533-540
[9]   A novel miniaturized flame ionization detector for portable gas chromatography [J].
Deng, CH ;
Yang, XH ;
Li, N ;
Huang, Y ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2005, 43 (07) :355-357
[10]   Determination of organochlorine pesticides and their metabolites in radish after headspace solid-phase microextraction using calix[4]arene fiber [J].
Dong, CZ ;
Zeng, ZR ;
Li, XJ .
TALANTA, 2005, 66 (03) :721-727