In vitro biocompatibility assessment of Ti40Cu38Zr10Pd12 bulk metallic glass

被引:25
|
作者
Blanquer, A. [1 ]
Pellicer, E. [2 ]
Hynowska, A. [2 ]
Barrios, L. [1 ]
Ibanez, E. [1 ]
Baro, M. D. [2 ]
Sort, J. [2 ,3 ]
Nogues, C. [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Biol Cel Lular Fisiol & Immunol, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Dept Fis, Bellaterra 08193, Spain
[3] Univ Autonoma Barcelona, ICREA, Bellaterra 08193, Spain
关键词
TITANIUM; CYTOTOXICITY; ADHESION; BEHAVIOR; ALLOY; PROLIFERATION; MODULATION; TANTALUM;
D O I
10.1007/s10856-013-5041-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of biocompatible materials has attained an increasing importance for tissue regeneration and transplantation. The excellent mechanical and corrosion properties of Ti40Cu38Zr10Pd12 bulk metallic glass (BMG) turn it into a potential candidate for its use in orthopaedic implants. Before being considered as a biomaterial, some biological parameters must be taken into account. In this study, mouse preosteoblasts were cultured in the presence or absence of the alloy at different times (24 h, 7 and 21 days) and no differences in cell viability were detected. Moreover, cells were able to adhere to the alloy surface by establishing focal contacts, and displayed a flattened polygonal morphology. After 14 days in culture, differentiation into osteoblasts was observed. Besides, the amount of Cu ions released and their potential toxic effects were analyzed, showing that the amount of Cu released did not increase cell death. Finally, the low levels of inflammatory cytokines secreted by THP-1 differentiated macrophages exposed to the alloy suggest the absence of an immunogenic response to the alloy. In conclusion, in vitro studies indicate that the Ti40Cu38Zr10Pd12 BMG could be considered as a biomaterial to be used in orthopaedic implants.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [1] Effect of Surface Modifications of Ti40Zr10Cu38Pd12 Bulk Metallic Glass and Ti-6Al-4V Alloy on Human Osteoblasts In Vitro Biocompatibility
    Blanquer, Andreu
    Hynowska, Anna
    Nogues, Carme
    Ibanez, Elena
    Sort, Jordi
    Dolors Baro, Maria
    Ozkale, Berna
    Pane, Salvador
    Pellicer, Eva
    Barrios, Leonardo
    PLOS ONE, 2016, 11 (05):
  • [2] In vitro corrosion and biocompatibility screening of sputtered Ti40Cu36Pd14Zr10 thin film metallic glasses on steels
    Subramanian, B.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 47 : 48 - 56
  • [3] Ti40Zr10Cu36Pd14 bulk metallic glass as oral implant material
    Rezvan, Amir
    Sharifikolouei, Elham
    Soprunyuk, Viktor
    Schranz, Wilfried
    Todt, Juraj
    Lassnig, Alice
    Gammer, Christoph
    Sifferlinger, Nikolaus August
    Asci, Atacan
    Okulov, Ilya
    Schlogl, Sandra
    Keckes, Jozef
    Najmi, Ziba
    Cochis, Andrea
    Scalia, Alessandro Calogero
    Rimondini, Lia
    Sarac, Baran
    Eckert, Juergen
    MATERIALS & DESIGN, 2023, 233
  • [4] Modification of structural, mechanical, corrosion and biocompatibility properties of Ti40Zr10Cu36Pd14 metallic glass by minor Ga and Sn additions
    Lachova, Andrea
    Stoica, Mihai
    Michalik, Stefan
    Gostin, Petre F.
    Fujioka-Kobayashi, Masako
    Schaller, Benoit
    Loeffler, Joerg F.
    Sovak, Pavol
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 940
  • [5] Influence of the shot-peening intensity on the structure and near-surface mechanical properties of Ti40Zr10Cu38Pd12 bulk metallic glass
    Gonzalez, S.
    Fornell, J.
    Pellicer, E.
    Surinach, S.
    Baro, M. D.
    Greer, A. L.
    Belzunce, F. J.
    Sort, J.
    APPLIED PHYSICS LETTERS, 2013, 103 (21)
  • [6] Formation of Hydroxyapatite on Ti-Coated Ti-Zr-Cu-Pd Bulk Metallic Glass
    Qin, F. X.
    Wang, X. M.
    Wada, T.
    Xie, G. Q.
    Asami, K.
    Inoue, A.
    MATERIALS TRANSACTIONS, 2009, 50 (03) : 605 - 609
  • [7] Relaxation of Ni-free Ti40Zr10Cu36Pd14 bulk metallic glass under mechanical stress
    Qiao, J. C.
    Wang, Q.
    Pelletier, J. M.
    Yao, Y.
    INTERMETALLICS, 2018, 102 : 6 - 10
  • [8] Antibacterial activity, cytocompatibility, and thermomechanical stability of Ti40Zr10Cu36Pd14 bulk metallic glass
    Rezvan, Amir
    Sharifikolouei, Elham
    Lassnig, Alice
    Soprunyuk, Viktor
    Gammer, Christoph
    Spieckermann, Florian
    Schranz, Wilfried
    Najmi, Ziba
    Cochis, Andrea
    Scalia, Alessandro Calogero
    Rimondini, Lia
    Manfredi, Marcello
    Eckert, Jurgen
    Sarac, Baran
    MATERIALS TODAY BIO, 2022, 16
  • [9] Thermal stability and crystallization kinetics of Ti40Zr10Cu34Pd14Sn2 bulk metallic glass
    Calin, Mariana
    Stoica, Mihai
    Zheng, Na
    Wang, Xiaorui
    Scudino, Sergio
    Gebert, Annett
    Eckert, Juergen
    ADVANCED MATERIALS AND STRUCTURES IV, 2012, 188 : 3 - +
  • [10] Zr61Ti2CU25Al12 metallic glass for potential use in dental implants: Biocompatibility assessment by in vitro cellular responses
    Li, Jing
    Shi, Ling-ling
    Zhu, Zhen-dong
    He, Qiang
    Ai, Hong-jun
    Xu, Jian
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (04): : 2113 - 2121