Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [21] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [22] Comparison of glomerular filtration rate estimation by 99mTc-DTPA to the reference radiotracer 51Cr-EDTA compared to methods based on blood creatinine measurement
    Saleh, N. S.
    Marie, S.
    Grimon, G.
    Durand, E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2021, 45 (03): : 142 - 146
  • [23] Measuring GFR Using the Plasma Clearance of 99mTc-DTPA
    Holness, Jennifer
    Fleming, John
    Warwick, James
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2015, 65 (05) : 806 - 806
  • [24] Clinical value of cystatin C and beta-trace protein in glomerular filtration rate in renal transplant cases with stable renal graft functions: comparison by the 99mTc-DTPA plasma sample method
    Oner, Ali Ozan
    Aydin, Funda
    Demirelli, Serkan
    Budak, Evrim S.
    Davran, Fatih
    Akbas, Halide
    Kocak, Huseyin
    Suleymanlar, Gultekin
    Gungor, Firat
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (07) : 733 - 744
  • [25] Prediction of renal function improvement in azotemic patients using glomerular filtration rate from 99mTc-DTPA renal scan An observational study
    Yu, Hoon
    Kim, Hyosang
    Shin, Hyung Soo
    Lee, Hyo Sang
    MEDICINE, 2021, 100 (51) : E28332
  • [26] CORRELATION BETWEEN SERUM CYSTATIN C AND 99MTC-DTPA GLOMERULAR FILTRATION RATE IN NEWLY DIAGNOSED TYPE 2 DIABETES MELLITUS PATIENTS
    Supriyadi, R.
    Dewi, S.
    Soelaeman, R.
    Sukandar, E.
    NEPHROLOGY, 2007, 12 : A43 - A44
  • [27] Comparison of 51Cr-EDTA with 99mTc-DTPA slope clearance for estimation of glomerular filtration rate using the one-compartment model
    Chapot, C
    Seifert, H
    Samnick, S
    Kirsch, CM
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1998, 37 (04): : 124 - 128
  • [28] Comparison of 99mTc-DTPA and serum creatinine, cystatin C in detection of glomerular filtration rate: a retrospective clinical data analysis of 744 Chinese subjects
    Yang, Shi-kun
    Zeng, Ling-feng
    Zhao, Qing-yu
    Zen, Zheng-peng
    Li, Ai-mei
    Zhang, Lin-Wei
    Li, Liu
    Song, Na
    Liu, Yan
    Zhang, Hao
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (03) : 219 - 227
  • [29] New normal values not related to age and sex, of glomerular filtration rate by 99mTc-DTPA renal dynamic imaging, for the evaluation of living kidney graft donors
    Zhao, Xiuyi
    Shao, Yahui
    Wang, Yanming
    Tian, Jun
    Sun, Ben
    Ru, Yanhui
    Zhang, Aimin
    Hao, Junwen
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2012, 15 (03): : 210 - 214
  • [30] Glomerular filtration rate with Tc99m DTPA. Comparison of methods.
    Noguera, ECA
    Jaime, A
    MEDICINA-BUENOS AIRES, 2000, 60 (02) : 211 - 216