Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [1] Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA
    Kazuo Itoh
    Satoshi Tsushima
    Eriko Tsukamoto
    Nagara Tamaki
    Annals of Nuclear Medicine, 2002, 16 : 39 - 44
  • [2] Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA
    Itoh, K
    Tsushima, S
    Tsukamoto, E
    Tamaki, N
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (03) : 143 - 150
  • [3] Nephrotoxicity of CDDP Assessed Estimating Glomerular Filtration Rate With 99mTc-DTPA Plasma Sample Method
    Fatima, Nosheen
    Niaz, Khalid
    Maseeh-Uz-Zaman
    Kamal, Shahid
    Hameed, Abid
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2010, 20 (02): : 98 - 101
  • [4] Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with99mTc-DTPA
    Kazuo Itoh
    Satoshi Tsushima
    Eriko Tsukamoto
    Nagara Tamaki
    Annals of Nuclear Medicine, 2000, 14 : 143 - 150
  • [5] A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes
    Houlihan, C
    Scott, A
    Jenkins, M
    Parkin, D
    Osicka, T
    Jerums, G
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1999, 29 (05): : 693 - 700
  • [6] Modified Schwartz formula and 99mTc-DTPA plasma clearance methods to calculate glomerular filtration rate in critically ill children
    Rohit Bhowmick
    Ramachandran Rameshkumar
    Madhusudhanan Ponnusamy
    Vishnukumar Rajaraman
    Muthu Chidambaram
    Abraar Sheriff
    Subramanian Mahadevan
    Pediatric Nephrology, 2022, 37 : 899 - 906
  • [7] Determination of the glomerular filtration rate in patients with type 2 diabetes: An assessment of the agreement between 51Cr-EDTA plasma clearance and 99mTc-DTPA plasma clearance, 99mTc-DTPA renography and plasma creatinine prediction equation
    Moralidis, Efstratios
    Papanastasiou, Emmanouil
    Didangelos, Triantafyllos
    Hilidis, Ilias
    Siountas, Anastasios
    Arsos, Georgios
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2020, 161
  • [8] Variability of estimated glomerular filtration rate and 99mTc-DTPA glomerular filtration rate: implications for a single time-point sampling regime
    Bonney, Lara M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (05) : 351 - 357
  • [9] 99mTc-DTPA volume of distribution, half-life and glomerular filtration rate in normal adults
    Holness, Jennifer L.
    Fleming, John S.
    Malaroda, Alessandra L.
    Warwick, James M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (10) : 1005 - 1014
  • [10] Simultaneous glomerular filtration rate determination using inulin, iohexol, and 99mTc-DTPA demonstrates the need for customized measurement protocols
    White, Christine A.
    Akbari, Ayub
    Allen, Celine
    Day, Andrew G.
    Norman, Patrick A.
    Holland, David
    Adams, Michael A.
    Knoll, Greg A.
    KIDNEY INTERNATIONAL, 2021, 99 (04) : 957 - 966