Temperatures in unprotected joints between steel beams and concrete-filled tubular columns in fire

被引:29
|
作者
Ding, J. [1 ]
Wang, Y. C. [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester M13 9PL, Lancs, England
关键词
Joints; Temperature calculation; Concrete-filled tubes; Fire tests; Section factor; Eurocode;
D O I
10.1016/j.firesaf.2008.02.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental, numerical and analytical results of temperatures in different components of unprotected joints between steel beams and concrete-filled tubular columns in fire, which forms part of a research project to investigate joint behaviour under fire conditions and robustness of steel structures under accidental fire attack. Accurate calculation of connection temperatures is an essential first step of this process. The joint types include fin plate, endplate, reverse channel and T-stub. The results of the experiments indicate that the different components that are in the same region of a joint may be considered to have the same temperature. This suggests that the lumped mass temperature calculation equation in EN 1993-1-2 for unprotected steelwork may be used to calculate joint temperatures, by using an equivalent section factor for all the joint components in the same region of the joint. Therefore, the main objective of this study is to derive suitable expressions to calculate the section factors for the different components of the joints tested in this study. The experimental results have also been used to assess the simple temperature calculation method in Annex D of EN 1993-1-2, which relates the joint temperatures to the temperature of the connected beam. It has been found that this method generates grossly inaccurate results. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 32
页数:17
相关论文
共 50 条
  • [1] Some considerations in the design of unprotected concrete-filled steel tubular columns under fire conditions
    Wang, YC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 44 (03) : 203 - 223
  • [2] Fire resistance of square double-skin concrete-filled steel tubular columns and concrete-filled double steel tubular columns
    Zhu, Hongjie
    Ahmed, Mizan
    Li, Chenliu
    Kong, Xiao
    Chen, Shicai
    Yang, Qingtian
    Ghazali, Habibah
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2024, 319
  • [3] Experimental study of the behaviour of joints between steel beams and concrete filled tubular (CFT) columns in fire
    Ding, J.
    Wang, Y. C.
    Orton, A.
    TUBULAR STRUCTURES XII, 2009, : 641 - 650
  • [4] High strength concrete-filled tubular steel columns in fire
    Bahr, O.
    TUBULAR STRUCTURES XII, 2009, : 461 - 467
  • [5] Shear Storage Capacity of Vertical Stiffener Joints between Concrete-Filled Double Steel Tubular Columns and Steel Beams
    Zhou, Zhijun
    Zhang, Yufen
    Wang, Miao
    Demoha, Krushar
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [6] Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columns
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    Chen, Xian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) : 484 - 496
  • [7] Fire behaviour of fire-protected concrete-filled steel tubular columns
    Lou, Guo-Biao
    Tan, Rui-Xin
    Qi, Hong-Hui
    Rao, Wen-Ting
    Huang, Dai-Fa
    Zhao, Xin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
  • [8] Fire performance of concrete-filled tubular columns
    Lie, TT
    Kodur, VKR
    INTERNATIONAL CONFERENCE ON TUBULAR STRUCTURES, PROCEEDINGS, 1996, : 86 - 96
  • [9] Experimental Research on Joints Behavior of Concrete-Filled Steel Tubular Columns
    He, Meili
    Yu, Hualong
    Cao, Yan
    Xia, Yongkang
    ADVANCED RESEARCH IN MATERIAL SCIENCE AND MECHANICAL ENGINEERING, PTS 1 AND 2, 2014, 446-447 : 1409 - +
  • [10] Design method for connections between concrete-filled square tubular columns and steel beams
    Lu, Xi-Lin
    Li, Xue-Ping
    Yu, Yong
    Tongji Daxue Xuebao/Journal of Tongji University, 2002, 30 (01): : 1 - 5