Computation of energy imparted in diagnostic radiology

被引:38
作者
Gkanatsios, NA [1 ]
Huda, W [1 ]
机构
[1] UNIV FLORIDA,COLL MED,DEPT RADIOL,GAINESVILLE,FL 32610
关键词
integral dose; energy imparted; waveform ripple; anode angle; patient dosimetry;
D O I
10.1118/1.597939
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega(z), absorbed by a semi-infinite water phantom with a thickness z, were computed for x-ray spectra with peak x-ray tube voltages ranging from 50-140 kV and with added filtration, ranging from 1-6 mm aluminum. For a given phantom thickness and peak x-ray tube voltage, the energy imparted was found to be directly proportional to the x-ray beam half-value layer (HVL) expressed in millimeters of aluminum. Values of omega(z) were generated for constant waveform x-ray tube voltages and an anode angle of 12 degrees, and were fitted to the expression omega(z) = alpha X HVL + beta. Fitted alpha and beta parameters are provided that permit the energy imparted to be determined for any combination of tube voltage, half-value layer, and phantom thickness from the product of the entrance skin exposure (free-in-air) and the corresponding x-ray beam area. The results obtained using our method for calculating energy imparted were compared with values of energy imparted determined using Monte Carlo techniques and anthropomorphic phantoms for a range of diagnostic examinations. At 60, 80, and 120 kV, absolute values of energy imparted obtained using our method differed by 8%, 10%, and 12%, respectively, from the corresponding results of Monte Carlo computations obtained for an anthropomorphic phantom. The method described in this paper permits a simple determination of energy imparted for any type of diagnostic x-ray examination which may be used to compare the radiologic risks from differing types of x-ray examinations, optimize imaging techniques with respect to the patient dose, or estimate the patient effective dose equivalent. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:571 / 579
页数:9
相关论文
共 36 条
[1]  
BERTHELSEN B, 1991, ACTA RADIOL, V32, P492
[2]  
BOONE J, 1994, COMMUNICATION
[3]   PARAMETRIZED X-RAY ABSORPTION IN DIAGNOSTIC-RADIOLOGY FROM MONTE-CARLO CALCULATIONS - IMPLICATIONS FOR X-RAY-DETECTOR DESIGN [J].
BOONE, JM .
MEDICAL PHYSICS, 1992, 19 (06) :1467-1473
[4]  
CAMERON J, 1992, HPS NEWSLETTER, P7
[5]   DETERMINATION OF INTEGRAL ABSORBED DOSE FROM EXPOSURE MEASUREMENTS [J].
CARLSSON, C .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1963, 1 (06) :433-&
[6]   INTEGRAL ABSORBED DOSES IN ROENTGEN DIAGNOSTIC PROCEDURES .I. DOSEMETER [J].
CARLSSON, C .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1965, 3 (04) :310-&
[7]   ENERGY IMPARTED TO THE PATIENT IN DIAGNOSTIC-RADIOLOGY - CALCULATION OF CONVERSION FACTORS FOR DETERMINING THE ENERGY IMPARTED FROM MEASUREMENTS OF THE AIR COLLISION KERMA INTEGRATED OVER BEAM AREA [J].
CARLSSON, GA ;
CARLSSON, CA ;
PERSLIDEN, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1329-1341
[8]  
FAULKNER K, 1992, RADIAT PROT DOSIM, V43, P131
[9]  
GKANATSIOS NA, 1995, THESIS U FLORIDA GAI
[10]   Patient dosimetry in diagnostic radiology - some practical considerations in an NHS Region [J].
Harrison, R.M. ;
Faulkner, K. ;
Davies, M.L. ;
Chapple, C.L. ;
Robson, K.J. ;
Broadhead, D.A. .
Journal of Radiological Protection, 1995, 15 (03)