Safety and efficacy of ultrasound assistance during internal jugular vein cannulation in neurosurgical infants

被引:35
作者
Lamperti, M. [1 ]
Caldiroli, D. [1 ]
Cortellazzi, P. [1 ]
Vailati, D. [1 ]
Pedicelli, A. [2 ]
Tosi, F. [3 ]
Piastra, M. [3 ]
Pietrini, D. [3 ]
机构
[1] Natl Neurol Inst C Besta, Dept Neuroanaesthesiol, I-20133 Milan, Italy
[2] Univ Cattolica Sacro Cuore, Sch Med, Dept Bioimaging & Radiol Sci, I-00168 Rome, Italy
[3] Univ Cattolica Sacro Cuore, Sch Med, Paediat Intens Care Unit, I-00168 Rome, Italy
关键词
Pediatrics; Cardiovascular monitoring; Peri-operative care;
D O I
10.1007/s00134-008-1210-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Ultrasound guidance (USG) for internal jugular cannulation is the best solution in difficult settings where paediatric patients are involved. This is an outcome study on efficacy and complications of the USG for the internal jugular vein (IJV) cannulation in neurosurgical infants as well as an ultrasound study of anatomical findings of the IJVs in infants. Design and settings: A prospective study conducted in two Academic Neurosurgical hospitals. Participants: In 191 babies (body weight < 15 kg), anatomical findings were studied. We performed CVC echo guided placement in 135/191 infants (weighting < 10 kg). Results: After a brief training period, both institutions adopted a common protocol and USG device. We obtained successful cannulation in all patients. Carotid puncture (1.5%) was the only main complication registered and minor complications were poor. Time required for cannulation was 12.5 +/- 5.7 min. Anatomical findings (in 191 patients) were IJV laterality in 34.6% cases, IJV antero-lateral in 59.7% and anterior in 5.7%. A linear relation was found between weight and internal jugular vein diameter even if R-2 stop = 0.43 and the model cannot be used to predict the exact size of the vein. In 62/135 babies weighting < 10 kg, anatomical measurements were done in supine and Trendelemburg position. Trendelemburg position increases significantly (P < 0.001) IJV diameter, but not IJV depth. Conclusions: We considered ultrasound guidance as the first choice in infants because it can enhance IJV cannulation success, safety, and allows one to measure relationships and diameter of the IJV and optimise the central line positioning.
引用
收藏
页码:2100 / 2105
页数:6
相关论文
共 22 条
  • [1] USE OF ULTRASOUND TO EVALUATE INTERNAL JUGULAR-VEIN ANATOMY AND TO FACILITATE CENTRAL VENOUS CANNULATION IN PEDIATRIC-PATIENTS
    ALDERSON, PJ
    BURROWS, FA
    STEMP, LI
    HOLTBY, HM
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (02) : 145 - 148
  • [2] Current practice of internal jugular venous cannulation in a university anesthesia department: Influence of operator experience on success of cannulation and arterial injury
    Augoustides, JG
    Diaz, D
    Weiner, J
    Clarke, C
    Jobes, DR
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (05) : 567 - 571
  • [3] COBB LM, 1987, SURG GYNECOL OBSTET, V165, P230
  • [4] COLLIER PE, 1995, J AM COLL SURGEONS, V181, P459
  • [5] de Jonge Rogier C J, 2005, Pediatr Crit Care Med, V6, P329, DOI 10.1097/01.PCC.0000161074.94315.0A
  • [6] Denda Sadahei, 2007, Masui, V56, P69
  • [7] Injuries and liability related to central vascular catheters - A closed claims analysis
    Domino, KB
    Bowdle, TA
    Posner, KL
    Spitellie, PH
    Lee, LA
    Cheney, FW
    [J]. ANESTHESIOLOGY, 2004, 100 (06) : 1411 - 1418
  • [8] PERCUTANEOUS CATHETERISATION OF INTERNAL JUGULAR VEIN
    ENGLISH, ICW
    FREW, RM
    PIGOTT, JF
    ZAKI, M
    [J]. ANAESTHESIA, 1969, 24 (04) : 521 - &
  • [9] GOSS CM, 1973, GRAYS ANATOMY, P697
  • [10] HAYASHI Y, 1992, ANESTH ANALG, V74, P688