Analysis of troponin I levels after spontaneous implantable cardioverter defibrillator shocks

被引:64
|
作者
Hasdemir, C
Shah, N
Rao, AP
Acosta, H
Matsudaira, K
Neas, BR
Reynolds, DW
Po, S
Lazzara, R
Beckman, KJ
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Cardiac Arrhythmia Res Inst, Oklahoma City, OK 73104 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Cardiovasc Sect, Oklahoma City, OK 73104 USA
关键词
implantable cardioverter defibrillator; defibrillation; troponin I;
D O I
10.1046/j.1540-8167.2002.00144.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Serum cardiac troponin I (cTnI) is a sensitive and specific marker for myocardial injury. Myocardial ischemia and/or injury can be a trigger for ventricular arrhythmias. The aim of this study was to assess the frequency and significance of elevated serum cTnI levels after spontaneous implantable cardioverter defibrillator (ICD) shocks. Methods and Results: Serial cTnI measurements and ECGs were performed in 35 patients with transvenous ICDs who were admitted after spontaneous ICD shocks. Elevated cTnI levels were found in 18 patients (51%). Acute coronary syndrome was diagnosed in 5 (22%) of 23 patients with known coronary artery disease. After excluding the patients with acute coronary syndrome, elevated cTnI levels were present in 13 (43%) of 30 patients: 18% of patients with less than or equal to3 shocks and 58% of patients with >3 shocks. Patients with elevated cTnI levels received a higher number of shocks (16 18 vs 5 7; P < 0.05) and had higher total delivered energies (475 538 J vs 128 184 J; P < 0.05) compared with patients with normal cTnI. Patients with acute coronary syndrome had higher peak cTnI levels (18 16 ng/mL) compared with patients with elevated cTnI without acute coronary syndrome (3.8 +/- 4.3 ng/mL; P < 0.01). Conclusion: Serum cTnI rises occur in the majority of patients after multiple (>3) spontaneous ICD discharges but are due to acute coronary syndrome only 14% of the time (22% of the time in patients with known coronary artery disease).
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [31] Recollection of Pain Due to Inappropriate Versus Appropriate Implantable Cardioverter-Defibrillator Shocks
    Marcus, Gregory M.
    Chan, Derrick W.
    Redberg, Rita F.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (03): : 348 - 353
  • [32] The incidence and impact of implantable cardioverter defibrillator shocks in the last phase of life: An integrated review
    Stoevelaar, Rik
    Brinkman-Stoppelenburg, Arianne
    Bhagwandien, Rohit E.
    van Bruchem-Visser, Rozemarijn L.
    Theuns, Dominic A. M. J.
    van der Heide, Agnes
    Rietjens, Judith A. C.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2018, 17 (06) : 477 - 485
  • [33] Catheter ablation of atrial tachyarrhythmias causing inappropriate implantable cardioverter-defibrillator shocks
    Miyazaki, Shinsuke
    Taniguchi, Hiroshi
    Kusa, Shigeki
    Komatsu, Yuki
    Ichihara, Noboru
    Takagi, Takamitsu
    Iwasawa, Jin
    Kuroi, Akio
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Hirao, Kenzo
    Iesaka, Yoshito
    EUROPACE, 2015, 17 (02): : 289 - 294
  • [34] Inappropriate implantable cardioverter defibrillator shocks-incidence, effect, and implications for driver licensing
    Watanabe, Eiichi
    Okajima, Katsunori
    Shimane, Akira
    Ozawa, Tomoya
    Manaka, Tetsuyuki
    Morishima, Itsuro
    Asai, Toru
    Takagi, Masahiko
    Honda, Toshihiro
    Kasai, Atsunobu
    Fujii, Eitaro
    Yamashiro, Kohei
    Kohno, Ritsuko
    Abe, Haruhiko
    Noda, Takashi
    Kurita, Takashi
    Watanabe, Shigeyuki
    Ohmori, Hiroya
    Nitta, Takashi
    Aizawa, Yoshifusa
    Kiyono, Ken
    Okumura, Ken
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (03) : 271 - 280
  • [35] Can We Avoid Inappropriate Implantable Cardioverter-Defibrillator Shocks The Answer Is in the Definition
    Deshmukh, Abhishek
    Friedman, Paul
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (06) : 716 - 718
  • [36] Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator
    Denollet, Johan
    Tekle, Fetene B.
    Pedersen, Susanne S.
    van der Voort, Pepijn H.
    Alings, Marco
    van den Broek, Krista C.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (06) : 2705 - 2709
  • [37] Inappropriate Shocks With Subcutaneous Implantable Cardioverter-Defibrillator in a Young Patient: A Case Report
    Khan, Zahid
    Sethumadhavan, Dinesh
    Rayner, Tom
    Kyaw, Sithu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [38] Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy?
    Ellenbogen, KA
    Levine, JH
    Berger, RD
    Daubert, JP
    Winters, SL
    Greenstein, E
    Shalaby, A
    Schaechter, A
    Subacius, H
    Kadish, A
    CIRCULATION, 2006, 113 (06) : 776 - 782
  • [39] Earlymortality after implantable cardioverter defibrillator: Incidence and associated factors
    Garcia, Rodrigue
    Boveda, Serge
    Defaye, Pascal
    Sadoul, Nicolas
    Narayanan, Kumar
    Perier, Marie-Cecile
    Klug, Didier
    Fauchier, Laurent
    Leclercq, Christophe
    Babuty, Dominique
    Bordachar, Pierre
    Gras, Daniel
    Deharo, Jean-Claude
    Piot, Olivier
    Providencia, Rui
    Marijon, Eloi
    Algalarrondo, Vincent
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 301 : 114 - 118
  • [40] Inappropriate detection in an implantable cardioverter defibrillator after generator change
    Narayanan, Kumar
    Sharifzadehgan, Ardalan
    Juin, Christophe
    Amet, Denis
    Swerdlow, Charles D.
    Marijon, Eloi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (06): : 736 - 738