Transcranial ultrasound-improved thrombolysis: Diagnostic vs. therapeutic ultrasound

被引:101
作者
Behrens, S
Spengos, K
Daffertshofer, M
Schroeck, H
Dempfle, CE
Hennerici, M [1 ]
机构
[1] Univ Heidelberg, Univ Klinikum Mannheim, Dept Neurol, D-68135 Mannheim, Germany
[2] Univ Heidelberg, Univ Klinikum Mannheim, Dept Internal Med 1, D-68135 Mannheim, Germany
[3] Univ Heidelberg, Inst Physiol, D-6800 Mannheim, Germany
关键词
cerebral revascularization; ultrasonics; thrombolysis; blood-brain barrier;
D O I
10.1016/S0301-5629(01)00481-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Success of stroke treatment with rt-PA depends on rapid vessel recanalization. Enzymatic thrombolysis may be enhanced by additional transcranial application of ultrasound (US). We investigated this novel technique using a 185-kHz probe and compared it to standard diagnostic US. In vitro studies were performed in a continuous pressure tubing system. Clots were placed in a postmortem skull and treated with rt-PA together with or without transtemporal 185-kHz US insonation (2W/cm(2)) and in comparison to 1-MHz diagnostic US (0.5 W/cm(2)). Recanalization time was significantly (p < 0.01) shorter in the 185-kHz (14.1 min) and 1-MHz (17.1 min) US rt-PA treatment group compared to rt-PA treatment alone (29.3 min.). Flow rate was significantly higher (P < 0.025) and increased faster in the combined treatment group with rt-PA + 185-kHz US compared to rt-PA + 1-MHz US. We investigated the blood-brain barrier in rats after 90-min exposure time of the brain with 185-kHz US, but no damage was observed. Results suggest efficacy and safety of the 185-kHz transducer, which is superior to diagnostic US. Such a novel US probe may be able to optimize thrombolytic stroke treatment. (E-mail: hennerici@neuro.ma.uni-heidelberg.de) (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1683 / 1689
页数:7
相关论文
共 34 条
[31]   Acceleration of thrombolysis with ultrasound through the cranium in a flow model [J].
Spengos, K ;
Behrens, S ;
Daffertshofer, M ;
Dempfle, CE ;
Hennerici, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05) :889-895
[32]   HIGH-INTENSITY, LOW-FREQUENCY CATHETER-DELIVERED ULTRASOUND DISSOLUTION OF OCCLUSIVE CORONARY-ARTERY THROMBI - AN IN-VITRO AND IN-VIVO STUDY [J].
STEFFEN, W ;
FISHBEIN, MC ;
LUO, H ;
LEE, DY ;
NITA, H ;
CUMBERLAND, DC ;
TABAK, SW ;
CARBONNE, M ;
MAURER, G ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (06) :1571-1579
[33]   SAFETY AND EFFICACY OF INTRAVENOUS TISSUE PLASMINOGEN-ACTIVATOR AND HEPARIN IN ACUTE MIDDLE CEREBRAL-ARTERY STROKE [J].
VONKUMMER, R ;
HACKE, W .
STROKE, 1992, 23 (05) :646-652
[34]   RELEASE OF BETA-THROMBOGLOBULIN FROM HUMAN PLATELETS BY THERAPEUTIC INTENSITIES OF ULTRASOUND [J].
WILLIAMS, AR ;
CHATER, BV ;
ALLEN, KA ;
SHERWOOD, MR ;
SANDERSON, JH .
BRITISH JOURNAL OF HAEMATOLOGY, 1978, 40 (01) :133-142